双能能谱CT评估儿童胆汁淤积性肝硬化肝脏血流动力学
回顾性纳入60例胆汁淤积性肝硬化患儿与15例肝功能正常的遗传代谢病患儿,采用能谱模式双能CT测量动脉期和门静脉期肝实质碘浓度并计算肝动脉碘分数。肝硬化组动脉期碘浓度和肝动脉碘分数与对照组存在差异,Child-Pugh C级组最高、对照组最低。作者认为动脉期碘浓度和肝动脉碘分数可作为评估肝脏血流动力学的半定量指标。
要点
- 在碘-水物质分解图上测量动脉期和门静脉期肝实质碘浓度,并计算肝动脉碘分数(AIF=动脉期碘浓度/门静脉期碘浓度)。
- 肝硬化患儿动脉期碘浓度和肝动脉碘分数随Child-Pugh分级升高而升高,Child-Pugh C级组最高、对照组最低。
- 门静脉期碘浓度在对照组与肝硬化组间无统计学显著差异。
核心结论
- 双能CT获得的动脉期碘浓度和肝动脉碘分数可作为半定量指标用于评估胆汁淤积性肝硬化患儿的肝脏血流动力学。
研究设计与样本
- 回顾性评估60例胆汁淤积性肝硬化患儿(研究组)和15例肝功能正常的遗传代谢病患儿(对照组)。
- 采用能谱成像模式行增强CT扫描,在碘-水物质分解图像上测量肝实质动脉期碘浓度(ICA)和门静脉期碘浓度(ICP),并计算肝动脉碘分数(AIF=ICA/ICP)。
- 采用单因素方差分析和Bonferroni校正事后检验比较对照组与研究组的ICA、ICP和AIF,并记录辐射剂量。
诊断标准与关键数值
- 肝动脉碘分数(AIF)计算公式为AIF=ICA/ICP,即在碘-水物质分解图像上测得的动脉期肝实质碘浓度除以门静脉期肝实质碘浓度。
- 对照组与研究组之间ICA和AIF存在差异,Child-Pugh C级组数值最高、对照组最低(p<0.05)。
- ICP在对照组与研究组之间无统计学显著差异(p>0.05)。
- 多数组间比较显示ICA和AIF存在差异(p<0.05)。
- 所有患者每个增强期的容积CT剂量指数均为10.14 mGy,总剂量长度乘积在402.68至679.18 mGy-cm之间。
临床应用与阅片要点
- 原作者认为双能CT的ICA和AIF可作为半定量指标评估胆汁淤积性肝硬化患儿的肝脏血流动力学。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to evaluate the value of dual-energy CT (DECT) in assessing liver hemodynamics in children with cholestatic cirrhosis. MATERIALS AND METHODS. The cases of 60 children with cholestatic cirrhosis (study group) and 15 children with inherited metabolic diseases but normal liver function (control group) were retrospectively evaluated. Enhanced CT scans were obtained in spectral imaging mode. Iodine concentration (IC) of hepatic parenchyma in the arterial phase (ICA) and portal venous phase (ICP) was measured on iodine-water material decomposition images. The hepatic arterial iodine fraction (AIF) was calculated as: AIF = ICA / ICP. The ICA, ICP, and AIF of children in the control and study groups were analyzed by one-way ANOVA and post hoc test with Bonferroni correction. The radiation dose was recorded. RESULTS. There were differences in ICA and AIF between the control and study groups. The values in patients in the Child-Pugh class C group were the highest and those in the control group the lowest (p < 0.05). Statistically significant differences in ICP were not found (p > 0.05). Specifically, the multiple comparison results indicated that there were differences in both ICA and AIF in most of the groups (p < 0.05). The volume CT dose index value for all patients was the same at 10.14 mGy for each enhanced phase, and the total dose-length product varied between 402.68 and 679.18 mGy-cm. CONCLUSION. ICA and AIF obtained at dual-energy CT can be used as semiquantitative indicators to evaluate the liver hemodynamics of children with cholestatic cirrhosis.
引用
- Shang S, Cao Q, Han X, et al. Assessing Liver Hemodynamics in Children With Cholestatic Cirrhosis by Use of Dual-Energy Spectral CT. AJR Am J Roentgenol. 2020. PMID: 31967500. doi:10.2214/AJR.19.22035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。