文献速递腹部MR

MRI技术对肝铁过载患者临床决策的影响:FerriScan与R2*衍生肝铁浓度比较

Impact of MRI technique on clinical decision-making in patients with liver iron overload: comparison of FerriScan- versus R2*-derived liver iron concentration.
PubMed 文献 · Eur Radiol · 2020-01-17

研究纳入106例铁过载患者,在1.5T西门子MAGNETOM Avanto Fit扫描仪上先后两次(间隔454±158天)行标准FerriScan MRI,第二次加做R2*-MRI映射,分别用固定阈值模型和两位血液科医生基于两次肝铁浓度趋势的回顾性决策模型比较两种技术下临床决策的一致性。固定阈值模型下R2*与FerriScan决策一致性良好,真阳性/阴性率均大于80%,假阳性/阴性率均小于10%,ROC曲线下面积大于0.95;第二种模型下两种情景的决策一致性在95%置信水平上相等。结论为从FerriScan转换为R2*肝铁浓度估测在患者管理决策上的一致性水平与更换一位血液科医生相当。

要点

  • 固定阈值模型下R2*与FerriScan肝铁浓度衍生决策一致性良好,真阳性/阴性率均大于80%,假阳性/阴性率均小于10%。
  • ROC分析显示曲线下面积大于0.95。
  • 从FerriScan转换为R2*肝铁浓度估测在患者管理决策上的一致性水平与更换一位血液科医生相当。

核心结论

  • 从FerriScan转换为R2*肝铁浓度估测在患者管理决策上的一致性水平与更换一位血液科医生相当。

研究设计与样本

  • 106例铁过载患者在1.5T西门子MAGNETOM Avanto Fit扫描仪上于两个连续时间点(间隔454±158天)成像,两个时间点均行标准FerriScan MRI方案,第二次检查时每例患者额外行R2*-MRI映射。

关键影像表现/征象

  • 固定阈值模型假定螯合剂调整严格基于固定的肝铁浓度阈值,决策仅取决于最近一次肝铁浓度值,无需临床医生输入。
  • 第二种模型采用两位血液科医生基于两次连续肝铁浓度值趋势的回顾性决策。

诊断标准与关键数值

  • 固定阈值模型下R2*与FerriScan衍生决策的真阳性率与真阴性率均大于80%。
  • 固定阈值模型下R2*与FerriScan衍生决策的假阳性率与假阴性率均小于10%。
  • ROC分析曲线下面积大于0.95。
  • 第二种模型下两种情景(κA与κB)的临床决策一致性在95%置信水平上相等。

临床应用与阅片要点

  • 从FerriScan转换为R2*肝铁浓度估测在患者管理决策上的一致性水平与更换一位血液科医生相当。
  • 固定阈值模型下R2*与FerriScan衍生决策一致性良好。
  • 第二种模型下两种情景的决策一致性在95%置信水平上相等。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to compare clinical decision-making in iron overload patients using FerriScan and an R2*-based approach.

METHODS: One-hundred and six patients were imaged at two consecutive timepoints (454 ± 158 days) on a 1.5-T Siemens MAGNETOM Avanto Fit scanner. For both timepoints, patients underwent the standard FerriScan MRI protocol. During the second exam, each patient additionally underwent R2*-MRI mapping. For each patient, a retrospective (simulated) decision was made to increase, decrease, or maintain chelator levels. Two different decision models were considered: The fixed threshold model assumed that chelator adjustments are based strictly on fixed liver iron concentration (LIC) thresholds. Decisions made with this model depend only on the most recent LIC value and do not require any clinician input. The second model utilized decisions made by two hematologists retrospectively based on trends between two consecutive LIC values. Agreement (κA) between hematologists (i.e., interobserver variability) was compared with the agreement (κB) between a single hematologist using the two different LIC techniques.

RESULTS: Good agreement between R2*- and FerriScan-derived decisions was achieved for the fixed threshold model. True positive/negative rates were greater than 80%, and false positive/negative rates were less than 10%. ROC analysis yielded areas under the curve greater than 0.95. In the second model, the agreement in clinical decision-making for the two scenarios (κA vs. κB) was equal at the 95% confidence level.

CONCLUSIONS: Switching to R2*-based LIC estimation from FerriScan has the same level of agreement in patient management decisions as does switching from one hematologist to another.

KEY POINTS: • Good agreement between R2*- and FerriScan-derived decisions in liver iron overload patient management • Switching to R2*-based LIC estimation from FerriScan has the same level of agreement in patient management decisions as does switching from one hematologist to another.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Sussman MS, Ward R, Kuo KHM, et al. Impact of MRI technique on clinical decision-making in patients with liver iron overload: comparison of FerriScan- versus R2*-derived liver iron concentration. Eur Radiol. 2020. PMID: 31953658. doi:10.1007/s00330-019-06450-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。