急性胰腺炎患者计算机断层扫描的辐射剂量:来自三级转诊医院的审计
该回顾性审计评估了351例急性胰腺炎患者共495次CT检查的辐射剂量,发现22.2%患者接受多次CT扫描,人均剂量24±15 mSv;改良CT严重指数≥8分者剂量显著更高(25.08 mSv vs. 18.96 mSv,P=0.048),双期扫描剂量显著高于单静脉期(13.26±7.64 mSv vs. 7.96±3.48 mSv,P<0.001),作者据此认为应避免常规动脉期采集。
要点
- 急性胰腺炎患者多次CT扫描可累积较高辐射剂量,22.2%患者人均24±15 mSv。
- 改良CT严重指数≥8分的重症患者辐射剂量显著高于轻症者。
- 双期扫描剂量显著高于单静脉期扫描,作者认为应避免常规动脉期采集。
核心结论
- 急性胰腺炎患者的CT扫描存在导致大量辐射暴露的潜在可能。
- 重症急性胰腺炎患者及接受双期扫描的患者辐射暴露显著更高。
- 作者结论认为应避免常规动脉期采集。
研究设计与样本
- 回顾性审查急性胰腺炎患者的CT报告。
- 共评估351例患者的495次CT检查。
- 记录CT扫描类型(平扫、单期、双期),计算人均CT扫描次数和累积辐射剂量。
- 记录双期CT扫描的适应证和异常表现,并比较不同类型扫描的辐射剂量。
关键影像表现/征象
- 在接受多次CT扫描的患者(n=78,22.2%)中,人均CT扫描次数为2.64±1.18次(范围2-9次),人均辐射剂量为24±15 mSv(范围8.3-79.8 mSv)。
- 共完成61次(12.32%)双期扫描,其中20例(32.7%)患者有明确的双期CT扫描适应证。
- 在因明确适应证行CT的患者中,6例(9.8%)检出动脉异常。
诊断标准与关键数值
- 改良CT严重指数≥8分的患者(n=63)平均辐射剂量为25.08 mSv,显著高于改良CT严重指数<8分者的18.96 mSv(P=0.048)。
- 双期扫描组平均辐射剂量为13.26±7.64 mSv(范围3.42-38.27 mSv),显著高于单静脉期扫描的7.96±3.48 mSv(P<0.001)。
临床应用与阅片要点
- 作者结论认为应避免常规动脉期采集。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: There is a limited data on the radiation dose from computed tomography (CT) in patients with acute pancreatitis (AP). The present study evaluated the radiation dose from CT scans in patients with AP.
MATERIAL: A retrospective review of CT reports of patients with AP was conducted. The type of CT scan (non-contrast vs. single-phase vs. biphasic CT) was recorded. The mean number of CT scans and cumulative radiation dose was calculated. The indications and abnormalities on biphasic CT scans were recorded. The radiation doses between different types of the scan were compared.
RESULTS: 495 CT studies in 351 patients were evaluated. In patients (n = 78, 22.2%) undergoing multiple CT scans, mean number of CT scans per patient and mean radiation dose were 2.64 ± 1.18 (range 2-9) and 24 ± 15 mSv (range 8.3-79.8 mSv), respectively. The mean radiation dose was significantly greater in patients with modified CT severity index ≥ 8 (n = 63) [25.08 mSv vs. 18.96 mSv, (P = 0.048)]. 61 (12.32%) biphasic scans were performed. A definite indication for a biphasic CT scan was identified in 20 (32.7%) patients. Arterial abnormalities were detected in 6 (9.8%) patients undergoing CT for defined indication. Mean radiation dose in this group was 13.26 ± 7.64 mSv (range 3.42-38.27 mSv) which was significantly greater than the single venous phase scan (7.96 ± 3.48 mSv, P < 0.001).
CONCLUSION: There is a potential for substantial radiation exposure from CT scans to patients with AP. Patients with severe AP and those undergoing biphasic scans have significantly higher radiation exposure. Hence, routine arterial phase acquisition should be avoided.
引用
- Gupta P, Jain R, Koshi S, et al. Radiation dose from computed tomography in patients with acute pancreatitis: an audit from a tertiary care referral hospital. Abdom Radiol (NY). 2020. PMID: 31960118. doi:10.1007/s00261-020-02408-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。