冠状动脉CT血管成像衍生的血流储备分数在右冠状动脉异常起源于左冠状窦患者中的应用
回顾性纳入94例冠状动脉CT血管成像显示右冠状动脉异常起源于左冠状窦并呈动脉间走行的患者,分析CT-FFR≤0.80与解剖特征的关系。开口水平、壁内走行和裂隙状开口是血流动力学异常的主要预测因素,准确率分别为0.69、0.71和0.81。CT-FFR≤0.80患者典型心绞痛(29.4% vs. 7.8%,p=0.025)和非典型心绞痛(29.4% vs. 6.5%,p=0.016)发生率更高,提示CT-FFR可能有助于评估临床相关性。
要点
- 裂隙状开口预测CT-FFR≤0.80的准确率为0.81,壁内走行为0.71,开口水平为0.69。
- CT-FFR≤0.80组典型心绞痛发生率为29.4%,CT-FFR正常组为7.8%(p=0.025)。
- CT-FFR≤0.80组非典型心绞痛发生率为29.4%,CT-FFR正常组为6.5%(p=0.016)。
关键影像表现/征象
- CT-FFR正常组与异常组在近端血管形态、开口水平、壁内走行、近端狭窄面积百分比和舒张期最小管腔面积上差异有统计学意义(均p<0.05)。
- 开口水平、壁内走行和裂隙状开口(均p<0.05)预测血流动力学异常(CT-FFR≤0.80)的准确率分别为0.69、0.71和0.81。
诊断标准与关键数值
- CT-FFR≤0.80定义为血流动力学异常。
- 裂隙状开口预测CT-FFR≤0.80的准确率为0.81,壁内走行为0.71,开口水平为0.69。
临床应用与阅片要点
- 阅片时关注右冠状动脉开口水平、有无壁内走行及开口形态是否为裂隙状,这些特征与CT-FFR≤0.80相关。
- CT-FFR≤0.80患者典型心绞痛(29.4% vs. 7.8%,p=0.025)和非典型心绞痛(29.4% vs. 6.5%,p=0.016)发生率更高,提示CT-FFR可能有助于评估临床相关性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To examine the fractional flow reserve derived from computed tomographic angiography (CT-FFR) in patients with anomalous origin of the right coronary artery from the left coronary sinus (R-ACAOS) with an interarterial course, assess the relationship of CT-FFR with the anatomical features of interarterial R-ACAOS on coronary computed tomographic angiography (CCTA), and determine its clinical relevance.
MATERIALS AND METHODS: Ninety-four patients with interarterial R-ACAOS undergoing CCTA were retrospectively included. Anatomic features (proximal vessel morphology [oval or slit-like], take-off angle, take-off level [below or above the pulmonary valve], take-off type, intramural course, % proximal narrowing area, length of narrowing, minimum luminal area [MLA] at systole and diastole, and vessel compression index) on CCTA associated with CT-FFR ≤ 0.80 were analyzed. Receiver operating characteristic analysis was performed to describe the diagnostic performance of CT-FFR ≤ 0.80 in detecting interarterial R-ACAOS.
RESULTS: Significant differences were found in proximal vessel morphology, take-off level, intramural course, % proximal narrowing area, and MLA at diastole (all p < 0.05) between the normal and abnormal CT-FFR groups. Take-off level, intramural course, and slit-like ostium (all p < 0.05) predicted hemodynamic abnormality (CT-FFR ≤ 0.80) with accuracies of 0.69, 0.71, and 0.81, respectively. Patients with CT-FFR ≤ 0.80 had a higher prevalence of typical angina (29.4% vs. 7.8%, p = 0.025) and atypical angina (29.4% vs. 6.5%, p = 0.016).
CONCLUSION: Take-off level, intramural course, and slit-like ostium were the main predictors of abnormal CT-FFR values. Importantly, patients with abnormal CT-FFR values showed a higher prevalence of typical angina and atypical angina, indicating that CT-FFR is a potential tool to gauge the clinical relevance in patients with interarterial R-ACAOS.
引用
- Tang CX, Lu MJ, Schoepf JU, et al. Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve in Patients with Anomalous Origin of the Right Coronary Artery from the Left Coronary Sinus. Korean J Radiol. 2020. PMID: 31997594. doi:10.3348/kjr.2019.0230
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。