文献速递心血管MRUS

心血管磁共振特征追踪评估舒张功能

Feature tracking for assessment of diastolic function by cardiovascular magnetic resonance imaging.
PubMed 文献 · Clin Radiol · 2019-12-31

研究纳入71例同时接受心血管磁共振(CMRI)与超声心动图检查的患者(43例舒张功能异常),以超声为参考标准,评估CMRI特征追踪(FT)参数诊断舒张功能障碍的一致性。CMRI-FT圆周舒张早期应变率(DSR)诊断准确性最高,与超声一致性良好(kappa 0.75),优于E/圆周DSR比值及相位对比(PC)评估。

要点

  • CMRI-FT圆周DSR与超声诊断舒张功能障碍一致性最高(kappa 0.75)。
  • CMRI-FT径向、圆周应变、收缩期应变率及舒张早期应变率识别舒张功能障碍AUC均>0.80。
  • CMRI测定LVEF≥50%者中,仅圆周DSR准确性良好(AUC=0.87,截断值0.93/s)。

核心结论

  • CMRI-FT圆周DSR判断舒张功能障碍准确性最高,与超声心动图一致性良好。
  • 圆周DSR准确性高于E/圆周DSR比值及PC评估。

研究设计与样本

  • 研究纳入71例患者,其中43例舒张功能异常,均独立接受CMRI与超声心动图检查。
  • 以超声心动图为参考标准。
  • CMRI-FT分析短轴及长轴 cine 轮廓;评估二尖瓣流入、组织速度、肺静脉血流及左房面积的PC图像。

关键影像表现/征象

  • CMRI-FT径向及圆周应变、收缩期应变率(SSR)、舒张早期应变率(DSR)识别舒张功能障碍的AUC均>0.80。

诊断标准与关键数值

  • CMRI测定LVEF≥50%者(n=38)中,圆周DSR是唯一准确性良好的参数(AUC=0.87;截断值0.93/s)。
  • E/圆周DSR比值及纵向应变在所有患者中准确性高(AUC分别为0.88和0.93),在CMRI测定LVEF≥50%者中AUC=0.81(截断值76.7)。
  • 圆周DSR与超声一致性最高(所有病例kappa 0.75,p<0.0001;CMRI LVEF≥50%者kappa 0.73,p<0.0001),高于E/圆周DSR及PC评估。

临床应用与阅片要点

  • CMRI-FT圆周DSR可作为评估舒张功能的参数,与超声一致性良好。
  • CMRI测定LVEF≥50%时,圆周DSR准确性良好(AUC=0.87,截断值0.93/s)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the agreement of cardiovascular magnetic resonance imaging (CMRI) feature-tracking (FT) parameters with echocardiography to diagnose diastolic dysfunction; to determine whether a similar parameter to mitral inflow early diastolic velocity to early diastolic tissue velocity ratio (E/e') can increase accuracy of imaging by dividing the phase contrast (PC) mitral inflow E-wave (E) with a CMRI-FT parameter; to compare the agreement between CMRI-FT and PC diastolic function assessment using echocardiography.

MATERIALS AND METHODS: Patients (n=71; 43 abnormal diastolic function) undergoing both CMRI and echocardiography independently were included. Echocardiography was the reference standard. CMRI-FT analysed the short and long axis cine contours. PC images of mitral inflow, tissue velocity, pulmonary vein flow, and left atrial area were assessed.

RESULTS: Using CMRI-FT, the area under the curve (AUC) for identifying diastolic dysfunction was >0.80 for radial and circumferential strain, systolic strain rate (SSR), and early diastolic strain rate (DSR). For cases with CMRI-determined left ventricular ejection fraction (LVEF) ≥50% (n=38), circumferential DSR was the only parameter with good accuracy (AUC=0.87; cut-off 0.93/s). E/circumferential DSR ratio and longitudinal strain had high accuracy in all patients (AUC=0.88 and 0.93 respectively) and CMRI-determined LVEF ≥50% (AUC=0.81; cut-off 76.7). Circumferential DSR showed the highest agreement with echocardiography (higher than E/circumferential DSR and PC assessment) in all cases (kappa 0.75; p<0001) and cases with CMRI LVEF ≥50% (kappa 0.73; p<0.0001).

CONCLUSIONS: CMRI-FT circumferential DSR showed the highest accuracy for determining diastolic dysfunction with good agreement with echocardiography. Circumferential DSR had higher accuracy than E/circumferential DSR and PC.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Ng MY, Tong X, He J, et al. Feature tracking for assessment of diastolic function by cardiovascular magnetic resonance imaging. Clin Radiol. 2019. PMID: 31898961. doi:10.1016/j.crad.2019.11.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。