超声时谐弹性成像定量主动脉僵硬度:血管内压力对猪模型弹性测量值的影响
研究在9头健康家猪离体胸腹主动脉上,用超声时谐弹性成像(THE)测量不同腔内压力(0–110 mmHg)下的剪切波速度(SWS),其中3条主动脉经4%甲醛浸泡模拟病理性僵硬。结果显示SWS随压力轻度升高,压力所致SWS占比为1.89%–8.60%,管腔直径与SWS无显著交互作用,提示THE有潜力测量主动脉壁固有僵硬度。
要点
- 离体猪主动脉模型中,腔内压力升高可使THE测得的SWS轻度增加,压力所致SWS占比为1.89%–8.60%。
- 甲醛浸泡主动脉的SWS在30 mmHg和110 mmHg下均显著高于未处理主动脉(各P=0.01)。
- 管腔直径与SWS无显著交互作用(P=0.893),提示直径不显著影响THE测值。
核心结论
- 在该模型中,超声时谐弹性成像测得的主动脉僵硬度受平均动脉压影响程度较小,范围为1.89%至8.60%。
- 这些发现强调超声THE在临床常规中测量主动脉壁固有僵硬度方面具有潜力。
研究设计与样本
- 研究类型为离体猪主动脉弹性成像实验,取9头健康家猪的胸腹主动脉。
- 所有血管连接可调高度的盐水水柱,在0至110 mmHg范围内以10 mmHg递增加压,模拟不同平均动脉压水平。
- 9条主动脉中的3条在4%缓冲甲醛中浸泡60分钟,以模拟病理性主动脉僵硬。
- 在每个压力水平对每条血管行超声THE,记录作为主动脉壁僵硬度指标的剪切波速度(SWS)和管腔直径。
- 统计评估采用30至110 mmHg压力范围,因其反映生理平均动脉压范围;行线性回归和多变量一般线性模型分析。
关键影像表现/征象
- 甲醛浸泡主动脉的中位SWS在30 mmHg为3.22 m/s(四分位距0.01 m/s),未处理主动脉为2.14 m/s(四分位距0.09 m/s)。
- 甲醛浸泡主动脉的中位SWS在110 mmHg为3.38 m/s(四分位距0.01 m/s),未处理主动脉为2.28 m/s(四分位距0.07 m/s)。
- 上述两个压力水平下甲醛浸泡主动脉与未处理主动脉的SWS差异均有统计学意义(各P=0.01)。
诊断标准与关键数值
- 线性回归分析显示,未处理主动脉SWS随腔内压力升高增加0.017 m/s每10 mmHg(P=0.001)。
- 甲醛浸泡主动脉SWS随腔内压力升高增加0.020 m/s每10 mmHg(P=0.001)。
- 腔内压力所致SWS占比在30 mmHg时为甲醛浸泡主动脉1.89%、未处理主动脉2.50%,在110 mmHg时为甲醛浸泡主动脉6.61%、未处理主动脉8.60%。
- 多变量分析显示管腔直径与测得SWS无显著交互作用(P=0.893)。
临床应用与阅片要点
- 作者认为,超声THE有潜力在临床常规中测量主动脉壁固有僵硬度。
- 解读THE测得的主动脉SWS时,需考虑平均动脉压对其有1.89%至8.60%的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to investigate blood pressure dependency of ultrasound time-harmonic elastography (THE) for quantification of aortic stiffness.
MATERIALS AND METHODS: Thoracoabdominal aortas were surgically removed from 9 healthy domestic pigs and prepared for elastographic experiments. All vessels were connected to a saline-filled water column with adjustable height and pressurized over a range of 0 to 110 mm Hg in 10 mm Hg increments to simulate different levels of mean arterial pressure. In addition, 3 of the 9 aortas were soaked in 4% buffered formaldehyde for 60 minutes to simulate pathologic aortic stiffening. Ultrasound THE was performed in each vessel at each pressure level. For each pressure level, shear-wave speed (SWS) as a measure of aortic wall stiffness and luminal diameter were recorded. The pressure range between 30 and 110 mm Hg was used for statistical evaluation as it reflects a physiological mean arterial pressure range. Linear regression analysis and multivariate analysis with a general linear model were performed to evaluate the influence of increasing intravascular pressure and vessel diameter on measured SWS.
RESULTS: Median SWS in formalin-soaked aortas was significantly higher with 3.22 m/s (interquartile range [IQR], 0.01 m/s) versus 2.14 m/s (IQR, 0.09) at 30 mm Hg and 3.38 m/s (IQR, 0.01 m/s) versus 2.28 m/s (IQR, 0.07 m/s) at 110 mm Hg (each P = 0.01). Using linear regression analysis, an increase of aortic wall SWS of 0.017 m/s per 10 mm Hg intraluminal pressure was found in untreated aortas, whereas SWS increased by 0.020 m/s per 10 mm Hg in formalin-soaked aortas (both P = 0.001). The percentage of SWS caused by intraluminal pressure was 1.89% in formalin-soaked aortas and 2.50% in untreated aortas at 30 mm Hg and 6.61% for formalin-soaked aortas and 8.60% for untreated aortas at 110 mm Hg. Multivariate analysis showed no significant interaction of luminal diameter and measured SWS (P = 0.893).
CONCLUSIONS: In our model, aortic stiffness measurements by ultrasound time-harmonic elastography are influenced to a small extent by mean arterial pressure in a range of 1.89% to 8.60%. These findings emphasize the potential of ultrasound THE for measuring the intrinsic stiffness of the aortic wall in clinical routine.
引用
- Schaafs LA, Tzschätzsch H, Steffen IG, et al. Quantification of Aortic Stiffness by Ultrasound Time-Harmonic Elastography: The Effect of Intravascular Pressure on Elasticity Measures in a Porcine Model. Invest Radiol. 2020. PMID: 31895220. doi:10.1097/RLI.0000000000000618
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。