文献速递心血管MR

多回波梯度回波自旋回波成像的心肌血氧水平依赖MRI

Blood Oxygen Level-Dependent MRI of the Myocardium with Multiecho Gradient-Echo Spin-Echo Imaging.
PubMed 文献 · Radiology · 2020-01-21

研究在3.0-T MRI上采用梯度回波自旋回波平面成像序列,对18名健康参与者和8名前瞻性招募的高血压参与者进行逐心动周期BOLD MRI,通过屏气CO2干预分析T2和T2*变化;健康参与者T2和T2*斜率均为正值,高血压参与者均为负值,组间差异显著(P < .001)。

要点

  • 梯度回波自旋回波平面成像序列可在逐心动周期获得空间稳定的T2和T2*图。
  • 健康参与者屏气期间T2和T2*均呈正斜率,高血压参与者呈负斜率。
  • T2和T2*斜率在健康与高血压参与者间差异有统计学意义(P < .001)。

关键影像表现/征象

  • 健康参与者平均T2值为43 msec ± 5,高血压参与者为46 msec ± 9。
  • 健康参与者平均T2*值为28 msec ± 5,高血压参与者为22 msec ± 5。
  • 屏气期间健康参与者T2平均正斜率为0.2 msec每心动周期 ± 0.1,T2*平均正斜率为0.2 msec每心动周期 ± 0.1。
  • 屏气期间高血压参与者T2平均负斜率为-0.2 msec每心动周期 ± 0.2,T2*平均负斜率为-0.1 msec每心动周期 ± 0.2。

诊断标准与关键数值

  • 采用非参数Mann-Whitney检验比较健康参与者与高血压参与者的T2和T2*变化。
  • 健康参与者与高血压参与者平均斜率差异在T2(P < .001)和T2*(P < .001)均有统计学意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Myocardial oxygenation imaging could help determine the presence of microvascular dysfunction associated with increased cardiovascular risk. However, it is challenging to depict the potentially small oxygenation alterations with current noninvasive cardiac MRI blood oxygen level-dependent (BOLD) techniques. Purpose To demonstrate the cardiac application of a gradient-echo spin-echo (GESE) echo-planar imaging sequence for dynamic and quantitative heartbeat-to-heartbeat BOLD MRI and evaluate the sequence in populations both healthy and with hypertension in combination with a breath hold-induced CO2 intervention. Materials and Methods GESE echo-planar imaging sequence was performed in 18 healthy participants and in eight prospectively recruited participants with hypertension on a 3.0-T MRI system. T2 and T2* maps were calculated per heartbeat with a four-parameter fitting technique. Septal regions of interests were used to determine T2 and T2* values per heartbeat and examined over the course of a breath hold to determine BOLD changes. T2 and T2* changes of healthy participants and participants with hypertension were compared by using a nonparametric Mann-Whitney test. Results GESE echo-planar imaging approach gave spatially stable T2 and T2* maps per heartbeat for healthy participants and participants with hypertension, with mean T2 values of 43 msec ± 5 (standard deviation) and 46 msec ± 9, respectively, and mean T2* values of 28 msec ± 5 and 22 msec ± 5, respectively. The healthy participants exhibited increasing T2 and T2* values over the course of a breath hold with a mean positive slope of 0.2 msec per heartbeat ± 0.1 for T2 and 0.2 msec per heartbeat ± 0.1 for T2*, whereas for participants with hypertension these dynamic T2 and T2* values had a mean negative slope of -0.2 msec per heartbeat ± 0.2 for T2 and -0.1 msec per heartbeat ± 0.2 for T2*. The difference in these mean slopes between healthy participants and participants with hypertension was significant for both T2 (P < .001) and T2* (P < .001). Conclusion Gradient-echo spin-echo echo-planar imaging sequence provided quantitative T2 and T2* maps per heartbeat and enabled dynamic heartbeat-to-heartbeat blood oxygen level-dependent (BOLD)-response imaging by analyzing changes in T2 and T2* over the time of a breath-hold intervention. This approach could identify differences in the BOLD response between healthy participants and participants with hypertension. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Friedrich in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. van den Boomen M, Manhard MK, Snel GJH, et al. Blood Oxygen Level-Dependent MRI of the Myocardium with Multiecho Gradient-Echo Spin-Echo Imaging. Radiology. 2020. PMID: 31961241. doi:10.1148/radiol.2020191845

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。