文献速递胸部CT

边缘影像组学特征作为肺腺癌病理浸润的影像生物标志物

Marginal radiomics features as imaging biomarkers for pathological invasion in lung adenocarcinoma.
PubMed 文献 · Eur Radiol · 2020-01-21

研究纳入两个队列共236例(训练集189例、验证集47例)表现为磨玻璃结节(GGNs)的肺腺癌患者,在CT图像上构建基线影像组学模型并加入基于瘤内强度累积分布函数(CDF)的边缘特征。加入边缘特征后三个分类器的AUC均提升,支持向量机提升最大(AUC提升0.0790),逻辑分类器验证集AUC达0.9825。作者认为新型边缘特征联合基线影像组学模型有助于术前CT区分浸润性腺癌与原位腺癌/微浸润性腺癌。

要点

  • 表现为磨玻璃结节的肺腺癌术前CT影像组学可预测病理浸润程度。
  • 加入基于瘤内强度累积分布函数的边缘特征后三个分类器AUC均提升。
  • 逻辑分类器验证集AUC最高达0.9825,支持向量机AUC提升最大为0.0790。

核心结论

  • 新型边缘特征联合基线影像组学模型有助于术前CT区分浸润性腺癌与原位腺癌和微浸润性腺癌。

研究设计与样本

  • 回顾性分析两个队列共236例因磨玻璃结节接受手术的患者(训练集189例、验证集47例),所有结节病理确诊为原位腺癌、微浸润性腺癌或浸润性腺癌;感兴趣区半自动标注后计算40个影像组学特征,用L1范数正则化筛选特征构建基线模型,并基于瘤内强度累积分布函数开发边缘特征构建联合模型,两种模型各测试三种分类器。

诊断标准与关键数值

  • 基线影像组学模型含5个特征,三种分类器平均AUC训练集0.8419、验证集0.9142;加入边缘特征后平均AUC训练集0.8560、验证集0.9581;支持向量机AUC提升0.0790,逻辑分类器验证集AUC达0.9825。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Lung adenocarcinomas which manifest as ground-glass nodules (GGNs) have different degrees of pathological invasion and differentiating among them is critical for treatment. Our goal was to evaluate the addition of marginal features to a baseline radiomics model on computed tomography (CT) images to predict the degree of pathologic invasiveness.

METHODS: We identified 236 patients from two cohorts (training, n = 189; validation, n = 47) who underwent surgery for GGNs. All GGNs were pathologically confirmed as adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IA). The regions of interest were semi-automatically annotated and 40 radiomics features were computed. We selected features using L1-norm regularization to build the baseline radiomics model. Additional marginal features were developed using the cumulative distribution function (CDF) of intratumoral intensities. An improved model was built combining the baseline model with CDF features. Three classifiers were tested for both models.

RESULTS: The baseline radiomics model included five features and resulted in an average area under the curve (AUC) of 0.8419 (training) and 0.9142 (validation) for the three classifiers. The second model, with the additional marginal features, resulted in AUCs of 0.8560 (training) and 0.9581 (validation). All three classifiers performed better with the added features. The support vector machine showed the most performance improvement (AUC improvement = 0.0790) and the best performance was achieved by the logistic classifier (validation AUC = 0.9825).

CONCLUSION: Our novel marginal features, when combined with a baseline radiomics model, can help differentiate IA from AIS and MIA on preoperative CT scans.

KEY POINTS: • Our novel marginal features could improve the existing radiomics model to predict the degree of pathologic invasiveness in lung adenocarcinoma.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Cho HH, Lee G, Lee HY, et al. Marginal radiomics features as imaging biomarkers for pathological invasion in lung adenocarcinoma. Eur Radiol. 2020. PMID: 31965255. doi:10.1007/s00330-019-06581-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。