文献速递头颈MR

头颈部MRI中径向3D采样T1加权梯度回波序列相较于2D涡轮自旋回波和笛卡尔3D梯度回波序列的优势

Advantages of a T1-Weighted Gradient-Recalled Echo (GRE) Sequence With a Radial 3D Sampling Approach Versus 2D Turbo Spin-Echo and Cartesian 3D GRE Sequences in Head and Neck MRI.
PubMed 文献 · AJR Am J Roentgenol · 2020-01-08

回顾性纳入26例头颈部炎性或肿瘤性疾病患者的1.5-T MRI数据集,比较径向3D GRE与2D TSE、笛卡尔3D GRE三种脂肪饱和T1加权序列。径向GRE的脂肪饱和评分显著优于TSE和笛卡尔GRE,因磁化率伪影不可评估面积较小,整体图像质量评分显著更优。

要点

  • 径向GRE脂肪饱和评分1.942,显著优于TSE的2.346(p=0.002)和笛卡尔GRE的2.365(p=0.008)。
  • 径向GRE整体图像质量评分1.635,显著优于TSE的2.423(p=0.000)和笛卡尔GRE的2.500(p=0.000)。
  • 径向GRE因磁化率伪影不可评估面积53.8 mm,小于TSE的59.8 mm(p=0.062)和笛卡尔GRE的59.6 mm(p=0.079)。

核心结论

  • 头颈部成像中,径向GRE相较于TSE和笛卡尔GRE具有改善脂肪饱和和减少磁化率伪影范围的优点,从而整体图像质量更优。

研究设计与样本

  • 回顾性研究,纳入26例头颈部炎性或肿瘤性疾病患者的MRI数据集,使用1.5-T系统,所有方案均包括增强后轴位三种脂肪饱和T1加权序列,比较轴向FOV及平面内和z轴空间分辨率。

诊断标准与关键数值

  • 脂肪饱和 homogeneity 采用5点Likert量表评分,径向GRE平均1.942,TSE平均2.346(p=0.002),笛卡尔GRE平均2.365(p=0.008)。
  • 异物伪影整体影响评分径向GRE 1.731、TSE 1.731(p=1.000)、笛卡尔GRE 1.769(p=0.414)。
  • 因磁化率伪影不可评估面积径向GRE 53.8 mm,TSE 59.8 mm(p=0.062),笛卡尔GRE 59.6 mm(p=0.079)。
  • 整体图像质量评分径向GRE 1.635,TSE 2.423(p=0.000),笛卡尔GRE 2.500(p=0.000)。

临床应用与阅片要点

  • 作者结论认为径向GRE在头颈部成像中脂肪饱和更好且磁化率伪影范围更小,整体图像质量更优。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to compare the image quality, including artifacts, of a T1-weighted gradient-recalled echo (GRE) MRI sequence with a radial sampling approach to that of both 2D turbo spin-echo (TSE) and cartesian 3D GRE MRI sequences performed in the head and neck region. MATERIALS AND METHODS. The retrospective study included 26 datasets of patients who underwent MRI examination for inflammatory or neoplastic diseases of the head and neck region performed using a 1.5-T system. All examination protocols comprised three fat-saturated T1-weighted sequences performed in the axial plane after contrast agent administration. Axial FOV and spatial resolution in plane and along the z-axis were recorded. Sequences were evaluated independently by two readers for qualitative and quantitative parameters, including homogeneity of fat saturation and discrimination of pharyngeal wall structures. Qualitative parameters were evaluated using a 5-point Likert scale. RESULTS. For comparison, mean values of Likert scale scores were generated from the two readers' data. Fat saturation was significantly better on the radial GRE sequences (1.942) than on the TSE (2.346; p = 0.002) and cartesian GRE (2.365; p = 0.008) sequences. The overall impact of foreign material artifacts was comparable among sequences (radial GRE, 1.731; TSE, 1.731 [p = 1.000]; cartesian GRE, 1.769 [p = 0.414]); however, on direct comparison, the mean area that was not evaluable because of susceptibility was smaller on radial GRE sequences (53.8 mm) than on TSE sequences (59.8 mm; p = 0.062) and cartesian GRE sequences (59.6 mm; p = 0.079). Overall image quality was 1.635 with the use of radial GRE, 2.423 with TSE (p = 0.000), and 2.500 with cartesian GRE (p = 0.000). CONCLUSION. For imaging of the head and neck region, radial GRE has several advantages, including improved fat saturation and reduced extent of susceptibility artifacts, compared with TSE and cartesian GRE, leading to improved overall image quality.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Fahlenkamp UL, Siepmann S, Fehrenbach U, et al. Advantages of a T1-Weighted Gradient-Recalled Echo (GRE) Sequence With a Radial 3D Sampling Approach Versus 2D Turbo Spin-Echo and Cartesian 3D GRE Sequences in Head and Neck MRI. AJR Am J Roentgenol. 2020. PMID: 31913067. doi:10.2214/AJR.19.21579

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。