文献速递胸部骨肌头颈外周血管心血管技术与安全CT

腹外双能CT应用:全面综述

Extra-abdominal dual-energy CT applications: a comprehensive overview.
PubMed 文献 · Radiol Med · 2020-01-10

本文概述双能CT的技术原理(双源、双层探测器、快速电压切换)及后处理算法(虚拟单能图像、虚拟平扫、碘叠加图),并总结其在肺部灌注、骨肌、头颈、血管和心脏等腹外领域的应用;作者指出该技术提供的信息广泛但尚未完全探索,持续引发放射科医生和临床医生的兴趣。

要点

  • 双能CT通过不同能量辐射组的衰减差异实现组织区分,碘识别与定量可反映体内静脉对比剂分布。
  • 虚拟单能图像可改善对比分辨率并减少金属伪影,虚拟平扫重建可降低剂量,碘叠加图可突出碘分布。
  • 双能CT已成功用于腹部以外部位,包括肺灌注、骨肌、头颈、血管和心脏,但潜力尚未完全探索。

核心结论

  • 双能CT技术提供的信息已相当广泛但尚未完全探索,其性能持续引发放射科医生和临床医生的兴趣。

研究设计与样本

  • 本文为全面综述,未报告系统检索范围与纳入文献数量。
  • 综述涉及双能CT的辐射能量获取技术,包括双源、双层探测器和快速电压切换。
  • 综述提及后处理算法包括虚拟单能图像、虚拟平扫重建和碘叠加图。

关键影像表现/征象

  • 不同身体组织分子因特定原子序数和电子密度不同,与不同辐射组相互作用产生不同衰减,从而实现最终区分。

临床应用与阅片要点

  • 虚拟单能图像可用于改善对比分辨率和减少金属伪影。
  • 虚拟平扫重建可用于降低剂量。
  • 碘叠加图可用于突出碘分布。
  • 碘识别与定量可提供体内静脉对比剂输送的重要信息。

局限性

  • 原文指出双能技术提供的信息潜力广泛但尚未完全探索。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Unlike conventional computed tomography, dual-energy computed tomography is a relatively novel technique that exploits ionizing radiations at different energy levels. The separate radiation sets can be achieved through different technologies, such as dual source, dual layers or rapid switching voltage. Body tissue molecules vary for their specific atomic numbers and electron density, and the interaction with different sets of radiations results in different attenuations, allowing to their final distinction. In particular, iodine recognition and quantification have led to important information about intravenous contrast medium delivery within the body. Over the years, useful post-processing algorithms have also been validated for improving tissue characterization. For instance, contrast resolution improvement and metal artifact reduction can be obtained through virtual monoenergetic images, dose reduction by virtual non-contrast reconstructions and iodine distribution highlighting through iodine overlay maps. Beyond the evaluation of the abdominal organs, dual-energy computed tomography has also been successfully employed in other anatomical districts. Although lung perfusion is one of the most investigated, this evaluation has been extended to narrowly fields of application, such as musculoskeletal, head and neck, vascular and cardiac. The potential pool of information provided by dual-energy technology is already wide and not completely explored, yet. Therefore, its performance continues to raise increasing interest from both radiologists and clinicians.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Cicero G, Ascenti G, Albrecht MH, et al. Extra-abdominal dual-energy CT applications: a comprehensive overview. Radiol Med. 2020. PMID: 31925704. doi:10.1007/s11547-019-01126-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。