相位对比MRV上横窦单侧不显影:发生率及非增强MRI与窦血栓形成的鉴别
回顾性分析208例3D相位对比MRV(VENC 30 cm/s)及常规脑MRI,横窦单侧不显影(较对侧管径≥50%不显影)见于72/208(34.6%)患者,其中56/72(77.8%)无血栓、16/72(22.2%)有血栓。DWI异常(横窦高信号或T2*磁敏感伪影)诊断血栓敏感度93.8%、特异度100.0%,其他非增强序列敏感度56.3%-68.8%、特异度91.1%-100.0%。结论:横窦不显影在相位对比MRV上常见,DWI可用于排除窦血栓。
要点
- 相位对比MRV上横窦单侧不显影常见,本组占34.6%(72/208)。
- 横窦不显影患者中22.2%(16/72)实为横窦血栓。
- DWI异常诊断血栓敏感度93.8%、特异度100.0%。
核心结论
- 横窦不显影在相位对比MRV上是常见现象,本组发生率为34.6%(72/208)。
- 当相位对比MRV上横窦不显影造成诊断困难且增强检查禁忌时,DWI可有效用于排除窦血栓。
研究设计与样本
- 回顾性分析连续3年期间接受3D相位对比MRV(VENC 30 cm/s)及常规脑MRI的208例患者。
- 常规脑MRI包括非增强矢状位T1、轴位T2、FLAIR、DWI、GRE及增强后3D-MPRAGE。
- 横窦不显影定义为MRV上横窦管径较对侧≥50%不显影。
- 非增强影像异常定义为T2、FLAIR、T1及DWI呈高信号,GRE及DWI上见T2*磁敏感伪影。
- 以增强后3D-MPRAGE确认横窦血栓诊断。
关键影像表现/征象
- MRV上横窦不显影见于72/208(34.6%)患者。
- 横窦不显影患者中56/72(77.8%)无横窦血栓,16/72(22.2%)有横窦血栓。
- 无横窦血栓患者中横窦不显影56/192(29.2%),横窦血栓患者中16/16(100%)见不显影。
- 非增强影像异常表现为T2、FLAIR、T1、DWI高信号及GRE、DWI上T2*磁敏感伪影。
诊断标准与关键数值
- DWI异常(横窦高信号或T2*磁敏感伪影)诊断横窦血栓敏感度93.8%、特异度100.0%。
- 其他非增强MRI序列诊断横窦血栓敏感度56.3%-68.8%、特异度91.1%-100.0%。
- 横窦不显影的MRV标准为横窦管径较对侧≥50%不显影。
临床应用与阅片要点
- 相位对比MRV发现横窦单侧不显影时,需结合非增强MRI序列鉴别生理性不显影与窦血栓。
- DWI上横窦高信号或T2*磁敏感伪影对诊断横窦血栓敏感度93.8%、特异度100.0%。
- 增强检查禁忌时,DWI可有效用于排除窦血栓。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Unilateral decreased/nonvisualization of a transverse dural sinus on MRV poses a diagnostic dilemma when gadolinium administration is contraindicated. We determined the frequency of unilateral decreased/nonvisualization of the transverse dural sinus and the performance of pregadolinium MR imaging sequences in diagnosing transverse sinus thrombosis in the presence of unilateral decreased/nonvisualization on phase-contrast MRV.
MATERIALS AND METHODS: We conducted a retrospective review of consecutive 3D phase-contrast MRV (VENC, 30 cm/s) and routine brain imaging (noncontrast sagittal T1, axial T2, FLAIR, DWI, GRE, and postgadolinium 3D-MPRAGE images) performed during a 3-year period for a total of 208 patients. Nonvisualization of a transverse dural sinus was defined as ≥50% nonvisualization of the transverse sinus caliber versus the contralateral side on MRV. Noncontrast imaging findings were considered abnormal when hyperintense signal was present on T2, FLAIR, T1, and DWI, and there were T2* blooming artifacts on GRE and DWI. Postgadolinium 3D-MPRAGE was used to confirm the diagnosis of transverse sinus thrombosis.
RESULTS: Nonvisualization of a transverse dural sinus was observed in 72/208 (34.6%) patients on MRV; 56/72 (77.8%) were without transverse sinus thrombosis, and 16/72 (22.2%) patients had transverse dural sinus thrombosis. Nonvisualization of a transverse dural sinus was seen in 56/192 (29.2%) patients without transverse sinus thrombosis and 16/16 (100%) with transverse sinus thrombosis. Abnormal findings on DWI (transverse sinus hyperintense signal or T2* blooming artifact) are 93.8% sensitive and 100.0% specific for transverse sinus thrombosis. Other noncontrast MR imaging sequences ranged from 56.3%-68.8% sensitive and 91.1%-100.0% specific.
CONCLUSIONS: Nonvisualization of a transverse dural sinus is a frequent phenomenon on phase-contrast MRV. DWI can be effectively used to exclude sinus thrombosis when nonvisualization of a transverse dural sinus is a diagnostic conundrum on phase-contrast MRV and contrast-enhanced studies are contraindicated.
引用
- Chang YM, Kuhn AL, Porbandarwala N, et al. Unilateral Nonvisualization of a Transverse Dural Sinus on Phase-Contrast MRV: Frequency and Differentiation from Sinus Thrombosis on Noncontrast MRI. AJNR Am J Neuroradiol. 2020. PMID: 31924604. doi:10.3174/ajnr.A6337
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。