基于数值模拟的不规则小颈动脉-眼动脉动脉瘤血流动力学是否不同于规则小动脉瘤和大动脉瘤
回顾性分析2015年4月至2018年6月106个颈动脉-眼动脉段动脉瘤的3D血管造影图像与计算流体动力学,分为规则小动脉瘤、不规则小动脉瘤和大动脉瘤三组。不规则小动脉瘤与大动脉瘤的低剪切应力面积百分比和高振荡剪切指数相似且均显著高于规则小动脉瘤,但不规则小动脉瘤的壁剪切应力和归一化壁剪切应力显著高于大动脉瘤而低于规则小动脉瘤。
要点
- 不规则小动脉瘤的低剪切应力面积百分比和振荡剪切指数与大动脉瘤相似,均高于规则小动脉瘤。
- 不规则小动脉瘤的壁剪切应力和归一化壁剪切应力高于大动脉瘤但低于规则小动脉瘤。
- 三组中位最大高度分别为规则小动脉瘤3.03 mm、不规则小动脉瘤4.59 mm、大动脉瘤11.06 mm,差异均有统计学意义。
诊断标准与关键数值
- 规则小动脉瘤、不规则小动脉瘤和大动脉瘤的中位最大高度分别为3.03 mm(四分位距2.49-4.22)、4.59 mm(四分位距3.86-5.32)和11.06 mm(四分位距9.28-13.69),所有P < 0.05。
- 不规则小动脉瘤与大动脉瘤的低剪切应力面积百分比无显著差异(P = 0.72),振荡剪切指数无显著差异(P = 0.27),且两者均显著高于规则小动脉瘤(所有P < 0.01)。
- 不规则小动脉瘤的壁剪切应力和归一化壁剪切应力显著高于大动脉瘤(P < 0.01,P < 0.01),但显著低于规则小动脉瘤(P < 0.01,P < 0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this study is to investigate whether hemodynamics of unruptured, irregular small intracranial aneurysms (SIAs) are different from those of regular ones and large intracranial aneurysms (LIAs) in ophthalmic artery segment of internal carotid artery (ICA).
METHODS: Between April 2015 and June 2018, 106 carotid-ophthalmic artery aneurysms were retrospectively analyzed using 3D angiographic images and computational fluid dynamics (CFD). Three categories were stratified: regular SIAs, irregular SIAs and LIAs. Statistical comparisons of the differences in clinical, morphological and hemodynamic parameters among regular SIA, irregular SIA and LIA groups were performed by one-way analysis of variance (ANOVA) or Kruskal-Wallis Test.
RESULTS: The median maximal height of regular SIA, irregular SIA and LIA were 3.03 (interquartile range: 2.49-4.22) mm, 4.59 (interquartile range: 3.86-5.32) mm and 11.06 (interquartile range: 9.28-13.69) mm, all P < 0.05). Low shear-stress area percentage (LSA%) and oscillatory shear index (OSI) of irregular SIAs and LIAs were not significantly different (P = 0.72, P = 0.27 respectively), and were significantly higher than those of regular SIAs (all P < 0.01). Wall shear stress (WSS) and normalized wall shear stress (NWSS) of irregular SIAs were significantly higher than those of LIAs (P < 0.01, P < 0.01 respectively), but lower than those of regular SIAs (P < 0.01, P < 0.01 respectively).
CONCLUSIONS: Special unruptured irregular SIAs share a similarity of hemodynamic characteristics with LIAs in high LSA% and high OSI, and are different from regular SIAs in hemodynamics.
引用
- Wan H, Huang L, Ge L, et al. Are hemodynamics of irregular small carotid-ophthalmic aneurysms different from those of regular ones and large aneurysms based on numerical simulation? Neuroradiology. 2020. PMID: 31925470. doi:10.1007/s00234-019-02348-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。