文献速递神经MR

磁敏感伪影对原发性脑肿瘤灌注MRI的影响:动脉自旋标记与动态磁敏感对比灌注的比较

Effects of Susceptibility Artifacts on Perfusion MRI in Patients with Primary Brain Tumor: A Comparison of Arterial Spin-Labeling versus DSC.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-01-23

研究纳入86个原发性脑肿瘤病灶,比较单相和多相动脉自旋标记与DSC灌注MRI在伴有或不伴有瘤内出血、钙化及术后改变的病灶中的诊断效能。多相动脉自旋标记的敏感度和特异度与DSC灌注相近,且不受出血和钙化影响;作者建议非对比多相动脉自旋标记可替代DSC灌注用于颅内肿瘤的诊断和随访。

要点

  • 多相动脉自旋标记在无出血/钙化/手术史组敏感度94.4%、特异度80%,有上述改变组敏感度78.3%、特异度88%。
  • DSC灌注rCBV在两组敏感度均较低(66.7%和69.6%),特异度接近100%。
  • 单相动脉自旋标记定性评估敏感度仅48.2%,多相为79.3%,两者特异度均为100%。

核心结论

  • 多相动脉自旋标记的敏感度和特异度与DSC灌注相近,且不受瘤内出血和钙化的影响。
  • 作者建议非对比多相动脉自旋标记可替代DSC灌注MR成像用于颅内肿瘤的诊断和随访。

研究设计与样本

  • 研究纳入86个原发性脑肿瘤病灶,均行单相和多相动脉自旋标记及DSC灌注MR成像。
  • 无瘤内出血/钙化且无手术史者归入组1(n=38),有上述改变者归入组2(n=48)。
  • 两种灌注方法均计算相对局部脑血流量,DSC另计算相对局部脑血容量。
  • 影像结果与组织病理学或随访进行对照。

诊断标准与关键数值

  • 组1多相动脉自旋标记rCBF的敏感度为94.4%、特异度为80%。
  • 组2多相动脉自旋标记rCBF的敏感度为78.3%、特异度为88%。
  • 组1 DSC灌注rCBF的敏感度为88.9%、特异度为75%;组2为78.3%和84%。
  • 组1 DSC灌注rCBV的敏感度为66.7%、特异度为100%;组2为69.6%和96%。
  • 定性评估中,单相和多相动脉自旋标记的敏感度分别为48.2%和79.3%,两者特异度均为100%。

临床应用与阅片要点

  • 作者建议非对比多相动脉自旋标记可替代DSC灌注MR成像用于颅内肿瘤的诊断和随访。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Our aim was to investigate the effects of intratumoral hemorrhage, calcification, and postoperative changes on the sensitivity of arterial spin-labeling and DSC perfusion MR imaging in patients with primary brain tumors.

MATERIALS AND METHODS: Eighty-six brain tumor lesions were examined with single-phase and multiphase arterial spin-labeling and DSC perfusion MR imaging. The lesions that had no intratumoral bleeding/calcifications and history of surgery were assigned to group 1 (n = 38), and the lesions that had these were assigned to group 2 (n = 48). The relative regional cerebral blood flow was calculated in both perfusion methods, and relative regional cerebral blood volume was calculated in DSC. Imaging results were correlated with histopathology or follow-up.

RESULTS: In the quantitative evaluation, the sensitivity and specificity of relative regional cerebral blood flow in multiphase arterial spin-labeling perfusion were 94.4% and 80% in group 1 and 78.3% and 88% in group 2, respectively. The sensitivity and specificity of relative regional cerebral blood flow in DSC perfusion were 88.9% and 75% in group 1 and 78.3% and 84% in group 2, respectively. The sensitivity and specificity of relative regional cerebral blood volume in DSC perfusion were 66.7% and 100% in group 1 and 69.6% and 96% in group 2, respectively. In the qualitative evaluation, the sensitivities for single-phase and multiphase arterial spin-labeling were 48.2% and 79.3%, respectively, with 100% specificity for both.

CONCLUSIONS: The sensitivity and specificity of multiphase arterial spin-labeling were similar to those of DSC perfusion irrespective of bleeding and calcification in primary brain tumors. Thus, we suggest that noncontrast multiphase arterial spin-labeling can be used instead of DSC perfusion MR imaging in the diagnosis and follow-up of intracranial tumors.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Maral H, Ertekin E, Tunçyürek Ö, et al. Effects of Susceptibility Artifacts on Perfusion MRI in Patients with Primary Brain Tumor: A Comparison of Arterial Spin-Labeling versus DSC. AJNR Am J Neuroradiol. 2020. PMID: 31974077. doi:10.3174/ajnr.A6384

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。