文献速递神经技术与安全CT

Frontier ASPECTS 软件与不同级别放射科医师在急性缺血性卒中患者 CT 检查评估中的表现比较

Comparison of the performance between Frontier ASPECTS software and different levels of radiologists on assessing CT examinations of acute ischaemic stroke patients.
PubMed 文献 · Clin Radiol · 2020-01-20

本研究回顾性纳入 55 例急性大脑中动脉缺血患者的平扫头颅 CT,比较 Frontier ASPECTS 软件、两名高年资和两名低年资放射科医师的 ASPECTS 评分,以随访平扫 CT 由两名非盲独立专家共识评分为参考标准。Frontier 与高年资医师和参考标准一致性极好(r=0.842 和 0.803),低年资医师仅为好(r=0.680);低年资医师借助 Frontier 后一致性提升至极好(r=0.852)。

要点

  • Frontier 软件评分与专家共识参考标准的一致性极好(r=0.842),与高年资医师(r=0.803)相仿。
  • 低年资医师独立评分与参考标准一致性仅为好(r=0.680),平均 ASPECTS 差异较大(1.35)。
  • 低年资医师借助 Frontier 后一致性提升至极好(r=0.852),平均差异和标准差均减小。

核心结论

  • 高年资放射科医师、Frontier 软件与专家共识 ASPECTS 评分间一致性高,且 Frontier 可提升低年资医师评估 AIS 患者 ASPECTS 的表现。

研究设计与样本

  • 回顾性、盲法研究,纳入 55 例急性大脑中动脉缺血患者,比较 Frontier 软件、两名高年资和两名低年资放射科医师对平扫头颅 CT 的 ASPECTS 评分,参考标准为随访平扫 CT 由另两名非盲独立专家共识评分,采用 ICC 和 Bland-Altman 分析。

诊断标准与关键数值

  • Frontier 与参考标准一致性极好(r=0.842),高年资医师与参考标准一致性极好(r=0.803),低年资医师与参考标准一致性为好(r=0.680)。
  • Bland-Altman 分析示低年资医师与参考标准的平均 ASPECTS 差异为 1.35(SD=1.42),Frontier 为 0.16(SD=1.24),高年资医师为 0.22(SD=1.13)。
  • 低年资医师借助 Frontier 后与参考标准一致性从好(r=0.680)提升至极好(r=0.852),平均 ASPECTS 差异和标准差均减小。

临床应用与阅片要点

  • Frontier 软件可用于辅助低年资放射科医师进行 ASPECTS 评分,以缩小其与专家共识评分的差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the performance of Frontier Alberta Stroke Program Early CT Score (ASPECTS) software with different levels of radiologists in assessing computed tomography (CT) examinations of patients with early acute ischaemic stroke (AIS), and to evaluate whether this software can improve the performance of rating by less experienced radiologists.

MATERIALS AND METHODS: Unenhanced brain CT examinations of 55 patients with acute middle cerebral artery ischaemia were scored separately by Frontier, two senior radiologists, and two junior radiologists retrospectively and blinded to any clinical information. Two junior radiologists then scored again with the assist of Frontier. The reference standard was defined as the ASPECTS on Follow-up unenhanced CT scored by another two non-blinded independent experts on a consensus basis. Statistical analysis was performed using intraclass correlation coefficient (ICC) analysis and Bland-Altman plots.

RESULTS: Frontier and senior radiologists in ASPECTS reading have excellent agreement with the reference standard (r=0.842 and 0.803, respectively), while only a good agreement was found between junior radiologists and reference standard (r=0.680). Bland-Altman analysis revealed the mean ASPECTS difference and SD difference of junior radiologists were larger (mean difference=1.35; SD=1.42) than that of Frontier and senior radiologists with reference standard (mean difference=0.16, 0.22; SD=1.24, 1.13, respectively). However, with the assist of Frontier, the agreement between junior radiologists and reference standard was improved from good (r=0.680) to excellent (r =0.852), and the mean ASPECTS difference and SD difference were reduced.

CONCLUSION: High agreement in ASPECTS rating between senior radiologists, Frontier, and expert consensus reading was found. Moreover, Frontier can improve the performance of less experienced radiologists to assess the ASPECTS of patients with AIS.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Li L, Chen Y, Bao Y, et al. Comparison of the performance between Frontier ASPECTS software and different levels of radiologists on assessing CT examinations of acute ischaemic stroke patients. Clin Radiol. 2020. PMID: 31973944. doi:10.1016/j.crad.2019.12.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。