Wave-CAIPI 磁敏感加权成像在扫描时间减半下达到与传统磁敏感加权成像相当的诊断效能
本研究回顾性纳入181例同时行传统SWI(扫描时间251秒)与wave-CAIPI SWI(扫描时间113秒)脑MRI的患者,评估两者检测脑微出血(CMBs)的一致性。wave-CAIPI SWI在CMBs存在性上一致率100%,MARS评分一致率94.5%,颅内病灶诊断一致率100%,图像质量无显著差异(p=0.20)。
要点
- wave-CAIPI SWI扫描时间113秒,约为传统SWI 251秒的一半,CMBs检测一致率100%。
- 按MARS评分,wave-CAIPI SWI与传统SWI一致率94.5%,按解剖部位划分一致率均超过97%。
- 颅内病灶(28例患者33个病灶)诊断一致率100%,图像质量无显著差异(p=0.20)。
核心结论
- wave-CAIPI SWI在扫描时间减半的情况下,对CMBs检测和颅内病灶诊断与传统SWI达到高度一致。
研究设计与样本
- 回顾性研究,纳入2017年9月至2017年11月连续181例同时行传统SWI(扫描时间251秒)和wave-CAIPI SWI(扫描时间113秒)脑MRI的患者。
- 所有图像由两名放射科医师独立采用MARS评分评估CMBs,一名神经放射科医师诊断颅内病灶并进行图像质量视觉评分。
关键影像表现/征象
- wave-CAIPI SWI与传统SWI在CMBs存在性上一致率100%,MARS评分一致率94.5%。
- 按解剖部位划分,wave-CAIPI SWI的MARS一致率均超过97%。
- 颅内病灶(28例患者33个病灶)诊断一致率100%。
- 两种序列图像质量无显著差异(p=0.20)。
诊断标准与关键数值
- CMBs检测采用Microbleed Anatomical Rating Scale(MARS)进行计数和分级。
- CMBs存在性一致率100%,MARS评分一致率94.5%,按解剖部位一致率均超过97%。
- 颅内病灶诊断一致率100%,图像质量评分差异无统计学意义(p=0.20)。
临床应用与阅片要点
- wave-CAIPI SWI可在约一半扫描时间内提供与传统SWI高度一致的CMBs检测和颅内病灶诊断信息。
- 阅片时可按MARS评分系统对CMBs进行解剖部位分类计数,wave-CAIPI SWI在各解剖部位的一致率均超过97%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We aimed to evaluate the agreement in the detection of cerebral microbleeds (CMBs) between conventional susceptibility-weighted imaging (SWI) and fast SWI using wave-controlled aliasing in parallel imaging (CAIPI) acceleration. We also scrutinized the diagnostic agreement for intracranial lesions and compared the image quality between both sequences.
METHODS: Institutional review board approval was obtained and informed consent was waived for this retrospective study. We included 181 consecutive patients who had undergone brain MRI with both conventional SWI (scan time, 251 s) and wave-CAIPI SWI (scan time, 113 s) from September 2017 to November 2017. All images were independently reviewed by two radiologists for the detection and counting of CMBs using the Microbleed Anatomical Rating Scale (MARS). One neuroradiologist diagnosed intracranial lesions and scored image quality using visual analysis. The agreement for detection of CMBs and intracranial lesions was calculated, and interobserver agreements were analyzed by using kappa and intraclass correlation.
RESULTS: For detection of CMBs, both the conventional and wave-CAIPI SWI showed significantly high agreement of 100% for the presence of CMBs, and 94.5% using MARS. Wave-CAIPI SWI achieved more than 97% agreement of MARS when divided by anatomical locations, with excellent agreement. Interobserver agreements were also excellent. The diagnosis for intracranial lesions (33 lesions in 28 patients) demonstrated 100% agreement. The image quality of both sequences is not significantly different (p = 0.20).
CONCLUSIONS: Wave-CAIPI SWI achieved high agreement for CMB detection and diagnosis of intracranial lesions compared to conventional SWI within half of the scan time.
KEY POINTS: • Wave-CAIPI SWI achieves a diagnostic performance for the detection of cerebral microbleeds that is comparable to that of conventional SWI in half the scan time. • Interobserver agreement for the detection (presence vs. absence) and counting of cerebral microbleeds of wave-CAIPI SWI was excellent. • Wave-CAIPI SWI demonstrated a 100% agreement for the diagnosis of intracranial lesions and comparable image quality compared to conventional SWI.
引用
- Chung MS, Lee EJ, Kim S, et al. Wave-CAIPI susceptibility-weighted imaging achieves diagnostic performance comparable to conventional susceptibility-weighted imaging in half the scan time. Eur Radiol. 2020. PMID: 31953660. doi:10.1007/s00330-019-06574-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。