文献速递神经MR

超分辨率全脑三维MR波谱成像用于绘制IDH1突变人胶质瘤的D-2-羟基戊二酸与肿瘤代谢

Super-Resolution Whole-Brain 3D MR Spectroscopic Imaging for Mapping D-2-Hydroxyglutarate and Tumor Metabolism in Isocitrate Dehydrogenase 1-mutated Human Gliomas.
PubMed 文献 · Radiology · 2020-01-07

研究纳入3例IDH1突变胶质瘤患者和3例健康者,前瞻性采用3-T全脑3D MR波谱成像优化D-2HG采集,并用超分辨率方法将体素从5.2×5.2×12 mm上采样至1.7×1.7×3 mm。模拟数据中,与样条插值相比,超分辨率上采样使峰值信噪比提高62%(P < .05)、结构相似性指数提高7.3%(P < .05)。结论认为,通过超分辨率框架对低分辨率3D MR波谱图像上采样,可实现IDH1突变人胶质瘤的高空间分辨率全脑D-2HG成像。

要点

  • 3-T全脑3D MR波谱成像可用于IDH1突变胶质瘤的D-2HG成像。
  • 超分辨率上采样将D-2HG图体素从5.2×5.2×12 mm提升至1.7×1.7×3 mm。
  • 模拟数据中峰值信噪比提高62%、结构相似性指数提高7.3%(P < .05)。

核心结论

  • 通过超分辨率框架对低分辨率3D MR波谱图像上采样,可在IDH1突变人胶质瘤中实现高空间分辨率全脑D-2HG成像。

研究设计与样本

  • 前瞻性研究,2018年3月至9月纳入3例IDH1突变胶质瘤患者(平均年龄50岁±21,2男)和3例健康者(平均年龄32岁±3,2男),采用3-T全脑3D MR波谱成像协议优化D-2HG。
  • 20例健康者(平均年龄33岁±5,16男)接受上采样MR波谱成像模拟。
  • 另以模拟健康与患者数据及体模测量进行验证,采用Mann-Whitney U检验比较峰值信噪比与结构相似性指数。

关键影像表现/征象

  • 超分辨率上采样改善了采集的3D MR波谱成像数据的组织对比度和结构信息。

诊断标准与关键数值

  • D-2HG图初始体素为5.2×5.2×12 mm,经超分辨率方法上采样至1.7×1.7×3 mm。
  • 模拟数据中,与样条插值相比,超分辨率上采样使峰值信噪比提高62%(P < .05)、结构相似性指数提高7.3%(P < .05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Isocitrate dehydrogenase (IDH) mutations are highly frequent in glioma, producing high levels of the oncometabolite D-2-hydroxyglutarate (D-2HG). Hence, D-2HG represents a valuable imaging marker for IDH-mutated human glioma. Purpose To develop and evaluate a super-resolution three-dimensional (3D) MR spectroscopic imaging strategy to map D-2HG and tumor metabolism in IDH-mutated human glioma. Materials and Methods Between March and September 2018, participants with IDH1-mutated gliomas and healthy participants were prospectively scanned with a 3-T whole-brain 3D MR spectroscopic imaging protocol optimized for D-2HG. The acquired D-2HG maps with a voxel size of 5.2 × 5.2 × 12 mm were upsampled to a voxel size of 1.7 × 1.7 × 3 mm using a super-resolution method that combined weighted total variation, feature-based nonlocal means, and high-spatial-resolution anatomic imaging priors. Validation with simulated healthy and patient data and phantom measurements was also performed. The Mann-Whitney U test was used to check that the proposed super-resolution technique yields the highest peak signal-to-noise ratio and structural similarity index. Results Three participants with IDH1-mutated gliomas (mean age, 50 years ± 21 [standard deviation]; two men) and three healthy participants (mean age, 32 years ± 3; two men) were scanned. Twenty healthy participants (mean age, 33 years ± 5; 16 men) underwent a simulation of upsampled MR spectroscopic imaging. Super-resolution upsampling improved peak signal-to-noise ratio and structural similarity index by 62% (P < .05) and 7.3% (P < .05), respectively, for simulated data when compared with spline interpolation. Correspondingly, the proposed method significantly improved tissue contrast and structural information for the acquired 3D MR spectroscopic imaging data. Conclusion High-spatial-resolution whole-brain D-2-hydroxyglutarate imaging is possible in isocitrate dehydrogenase 1-mutated human glioma by using a super-resolution framework to upsample three-dimensional MR spectroscopic images acquired at lower resolution. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Huang and Lin in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Li X, Strasser B, Jafari-Khouzani K, et al. Super-Resolution Whole-Brain 3D MR Spectroscopic Imaging for Mapping D-2-Hydroxyglutarate and Tumor Metabolism in Isocitrate Dehydrogenase 1-mutated Human Gliomas. Radiology. 2020. PMID: 31909698. doi:10.1148/radiol.2020191529

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。