反复放射学检查患者累积辐射剂量的多国数据:呼吁采取行动
累积有效剂量≥100 mSv的患者数远多于既往已知或预期。
要点
- 反复CT等放射学检查可使患者累积有效剂量超过100 mSv,器官剂量进入辐射效应受关注的范围。
- 累积有效剂量≥100 mSv的患者数比既往已知或预期的多得多,全球每年可能新增90万例。
- 需建立累积辐射暴露预警值并纳入剂量监测系统,同时制定适宜性标准和转诊指南。
关键影像表现/征象
- 累积有效剂量≥100 mSv的患者数远多于既往已知或预期。
- 全球每年可能另有90万患者达到累积有效剂量≥100 mSv。
诊断标准与关键数值
- 累积有效剂量≥100 mSv定义为所关注的水平,此时器官剂量通常处于辐射效应受关注的范围。
临床应用与阅片要点
- 对个体患者的辐射暴露进行追踪可提供累积辐射剂量的有用信息。
- 应在剂量监测系统中设置并引入患者累积辐射暴露的预警值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To have a global picture of the recurrent use of CT imaging to a level where cumulative effective dose (CED) to individual patients may be exceeding 100 mSv at which organ doses typically are in a range at which radiation effects are of concern METHODS: The IAEA convened a meeting in 2019 with participants from 26 countries, representatives of various organizations, and experts in radiology, medical physics, radiation biology, and epidemiology. Participants were asked to collect data prior to the meeting on cumulative radiation doses to assess the magnitude of patients above a defined level of CED.
RESULTS: It was observed that the number of patients with CED ≥ 100 mSv is much larger than previously known or anticipated. Studies were presented in the meeting with data from about 3.2 million patients who underwent imaging procedures over periods of between 1 and 5 years in different hospitals. It is probable that an additional 0.9 million patients reach the CED ≥ 100 mSv every year globally.
CONCLUSIONS: There is a need for urgent actions by all stakeholders to address the issue of high cumulative radiation doses to patients. The actions include development of appropriateness criteria/referral guidelines by professional societies for patients who require recurrent imaging studies, development of CT machines with lower radiation dose than today by manufacturers, and development of policies by risk management organizations to enhance patient radiation safety. Alert values for cumulative radiation exposures of patients should be set up and introduced in dose monitoring systems.
KEY POINTS: • Recurrent radiological imaging procedures leading to high radiation dose to patients are more common than ever before. • Tracking of radiation exposure of individual patients provides useful information on cumulative radiation dose. • There is a need for urgent actions by all stakeholders to address the issue of high cumulative radiation doses to patients.
引用
- Brambilla M, Vassileva J, Kuchcinska A, et al. Multinational data on cumulative radiation exposure of patients from recurrent radiological procedures: call for action. Eur Radiol. 2019. PMID: 31792583. doi:10.1007/s00330-019-06528-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。