早产与足月新生儿骨健康的超声背散射差异测量

Ultrasonic Backscatter Difference Measurement of Bone Health in Preterm and Term Newborns.
PubMed 文献 · Ultrasound Med Biol · 2019-11-29

本研究对493例新生儿(足月239例、早产I 201例、早产II 53例)于出生时行跟骨超声背散射测量并计算nMBD。足月儿nMBD中位数3.72 dB/μs,高于早产I的1.95 dB/μs,早产I又高于早产II的0.19 dB/μs。nMBD与胎龄及体格指标呈中等相关,仅出生长度和BMI对nMBD有独立贡献,二者组合可解释42%的变异。

要点

  • 跟骨超声背散射nMBD随胎龄降低而降低:足月儿中位数3.72 dB/μs,早产I 1.95 dB/μs,早产II 0.19 dB/μs。
  • nMBD与胎龄及出生体重、出生长度、出生头围、BMI呈中等相关(ρ=0.57-0.62,p<0.001)。
  • 多变量回归中仅出生长度(p=0.002)与BMI(p=0.032)对nMBD有独立贡献,二者组合可解释42%的nMBD变异。

核心结论

  • 超声背散射差异测量可能有助于评估早产与足月新生儿的骨健康。
  • 超声背散射测量在诊断婴儿代谢性骨病中的效用需进一步研究。

研究设计与样本

  • 本研究共分析493例新生儿,包括足月儿239例(胎龄>37周)、早产I 201例(胎龄32-37周)和早产II 53例(胎龄<32周)。
  • 于出生时对婴儿跟骨行超声背散射测量,计算背散射差异谱归一化均值(nMBD)作为新生儿骨状态的超声指标。
  • 采用简单线性回归与多重线性回归分析nMBD与胎龄、体格特征及生化标志物的关联。

关键影像表现/征象

  • 足月儿nMBD中位数为3.72 dB/μs(四分位距1.95 dB/μs),显著高于早产I的1.95 dB/μs(四分位距3.12 dB/μs)。
  • 早产I的nMBD显著高于早产II的0.19 dB/μs(四分位距3.50 dB/μs)。

诊断标准与关键数值

  • nMBD与胎龄及体格特征呈中等相关(ρ=0.57-0.62,p<0.001)。
  • nMBD与生化标志物呈弱相关(|ρ|=0.08-0.21,p<0.001或无统计学意义)。
  • 多变量回归显示仅出生长度(p=0.002)与BMI(p=0.032)对nMBD有显著独立贡献,二者组合可解释新生儿nMBD变异的42%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文结论指出超声背散射测量在诊断婴儿代谢性骨病中的效用需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Metabolic bone disease of prematurity remains a significant problem for preterm infants. Quantitative ultrasound (QUS) has potential as a non-invasive tool for assessing bone health of newborns. The aim of this study was to assess bone health in preterm and term newborns using ultrasonic backscatter difference measurement. This study analyzed a total of 493 neonates, including 239 full-term infants (gestational age [GA] >37 wk), 201 preterm I infants (GA: 32-37 wk) and 53 extreme preterm II infants (GA <32 wk). Ultrasonic backscatter measurements were performed on the calcaneus of infants at birth, and the normalized mean of the backscatter difference spectrum (nMBD) was calculated as an ultrasonic index of neonatal bone status. Simple and multiple linear regressions were performed to determine the association of ultrasonic nMBD with GA, anthropometric characteristics and biochemical markers. Statistically significant differences in GA, anthropometric characteristics (birth weight, birth length [BL], birth head circumference and body mass index [BMI]) and biochemical markers (alkaline phosphatase, serum calcium and serum phosphate) were observed among preterm and term infants. The nMBD for term infants (median = 3.72 dB/μs, interquartile range [IR] = 1.95 dB/μs) was significantly higher than that for preterm I infants (median = 1.95 dB/μs, IR = 3.12 dB/μs), which was, in turn, significantly higher than that for preterm II infants (median = 0.19 dB/μs, IR = 3.50 dB/μs). The nMBD yielded moderate correlations (ρ = 0.57-0.62, p < 0.001) with GA and anthropometric characteristics and weak correlations (|ρ| = 0.08-0.21, p < 0.001 or not significant) with biochemical markers. Multivariate regressions revealed that only BL (p = 0.002) and BMI (p = 0.032) yielded significantly independent contributions to the nMBD measurement, and combinations of BL and BMI could explain up to 42% of the variation of nMBD in newborn infants. This study found that ultrasonic backscatter difference measurement might be helpful in bone health evaluation in preterm and term newborns. The utility of ultrasonic backscatter measurement in diagnosis of metabolic bone disease in infants should be investigated further.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Liu C, Li B, Li Y, et al. Ultrasonic Backscatter Difference Measurement of Bone Health in Preterm and Term Newborns. Ultrasound Med Biol. 2019. PMID: 31791554. doi:10.1016/j.ultrasmedbio.2019.10.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。