文献速递骨肌MR

1.5 T 下拇指腕掌关节与三角纤维软骨复合体的 T2 mapping:可行性与可重复性研究

T2 mapping of the trapeziometacarpal joint and triangular fibrocartilage complex: a feasibility and reproducibility study at 1.5 T.
PubMed 文献 · Radiol Med · 2019-12-20

研究纳入 34 名健康志愿者,在 1.5 T MR 上采用轴位斜面多层面多回波自旋回波序列测量拇指腕掌关节与三角纤维软骨复合体软骨的 T2 弛豫时间,其中 10 人在另一台 1.5 T 扫描仪上重复检查。两名肌骨放射科医师独立勾画感兴趣区,用 Bland-Altman 法评价观察者内、观察者间及扫描仪间可重复性。结论认为该测量似乎可行且可重复,但拇指腕掌关节 T2 测量的扫描仪间可重复性欠佳,需纳入患者进一步研究以证明其效用。

要点

  • 健康志愿者拇指腕掌关节软骨 T2 均值约 30 ms,三角纤维软骨复合体约 24.5 ms。
  • 观察者间可重复性拇指腕掌关节 76%、三角纤维软骨复合体 82%。
  • 扫描仪间可重复性拇指腕掌关节仅 36%,三角纤维软骨复合体为 85%。

核心结论

  • 拇指腕掌关节与三角纤维软骨复合体软骨的 T2 弛豫时间测量似乎可行且可重复,但拇指腕掌关节 T2 测量的扫描仪间可重复性欠佳。
  • 作者认为需纳入患者进一步研究以证明该工具的效用。

研究设计与样本

  • 可行性与可重复性研究,纳入 34 名健康志愿者,其中 10 人在另一台 1.5 T 扫描仪上重复 MR 检查。
  • 采用 1.5 T MR 轴位斜面多层面多回波自旋回波序列扫描腕部。
  • 由两名肌骨放射科医师独立手动勾画感兴趣区,包括拇指腕掌关节与三角纤维软骨复合体的软骨部分。
  • 采用 Bland-Altman 法检验观察者内、观察者间及扫描仪间 T2 弛豫时间测量的可重复性。

诊断标准与关键数值

  • 两名放射科医师测得的 T2 均值:拇指腕掌关节分别为 29.9 ± 6.5 ms 与 30.0 ± 6.1 ms,三角纤维软骨复合体分别为 24.5 ± 2.3 ms 与 24.6 ± 2.8 ms。
  • 资深放射科医师第二次系列 T2 测量均值:拇指腕掌关节 29.9 ± 6.5 ms 与 30.0 ± 6.3 ms,三角纤维软骨复合体 24.3 ± 2.9 ms。
  • 观察者间可重复性:拇指腕掌关节 76%,三角纤维软骨复合体 82%。
  • 观察者内可重复性:拇指腕掌关节 71%,三角纤维软骨复合体 76%。
  • 扫描仪间可重复性:拇指腕掌关节 36%,三角纤维软骨复合体 85%。

临床应用与阅片要点

  • 在健康志愿者中,1.5 T 下测量拇指腕掌关节与三角纤维软骨复合体软骨 T2 弛豫时间似乎可行且可重复。
  • 拇指腕掌关节 T2 测量的扫描仪间可重复性为 36%,原文认为其欠佳。
  • 作者认为需纳入患者进一步研究以证明该工具的效用。

局限性

  • 原文指出拇指腕掌关节 T2 测量的扫描仪间可重复性欠佳。
  • 原文结论提出需纳入患者进一步研究以证明该工具的效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the feasibility and reproducibility of T2 relaxation time measurements of the trapeziometacarpal joint (TM) and triangular fibrocartilage complex (TFCC) on healthy subjects at 1.5 T MR.

MATERIALS AND METHODS: Thirty-four healthy volunteers underwent an axial oblique multislice multiecho spin-echo sequence of the wrist at 1.5 T, with 10 of them having performed another MR scan on a different 1.5 T scanner. Regions of interest were independently manually drawn by two musculoskeletal radiologists to include the cartilaginous part of the TM and TFCC. Intra-observer, inter-observer and inter-scanner reproducibility of T2 relaxation time measurements was tested using the Bland-Altman method.

RESULTS: The mean T2 values obtained by the two radiologists were 29.9 ± 6.5 ms and 30.0 ± 6.1 ms in the TM and 24.5 ± 2.3 ms and 24.6 ± 2.8 ms in the TFCC, respectively. The mean values of the second series of T2 measurements obtained by the senior radiologist were 29.9 ± 6.5 ms and 30.0 ± 6.3 ms in the TM and 24.3 ± 2.9 ms in the TFCC. Inter-observer reproducibility in the TM and in the TFCC was 76% and 82%, respectively. Intra-observer reproducibility in the TM and TFCC was 71% and 76%, respectively. Inter-scanner reproducibility of T2 measurements was 36% in the TM and 85% in the TFCC, respectively.

CONCLUSION: The assessment of T2 relaxation time measurements of the cartilage of the TM and the TFCC seems to be feasible and reproducible, although the inter-scanner reproducibility of T2 measurements of the TM is suboptimal. Further studies including patients are warranted to prove the utility of this tool.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Chianca V, Albano D, Cuocolo R, et al. T2 mapping of the trapeziometacarpal joint and triangular fibrocartilage complex: a feasibility and reproducibility study at 1.5 T. Radiol Med. 2019. PMID: 31863359. doi:10.1007/s11547-019-01123-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。