数字化乳腺X线摄影在乳腺癌筛查中的效果:对超过800万韩国女性的比较研究
该研究回顾性分析2011年1月1日至2013年12月31日全国乳腺癌筛查项目与全国癌症登记链接的数据,纳入8 482 803名40-79岁韩国女性,比较SFM、CR与FFDM的筛查准确性。FFDM的敏感度和PPV高于SFM和CR,特异度较低,总体AUC为0.80,高于SFM的0.75和CR的0.76。
要点
- FFDM筛查的敏感度和PPV高于SFM和CR,但特异度低于两者。
- FFDM总体AUC为0.80,高于SFM的0.75和CR的0.76。
- 年龄、乳腺密度和筛查轮次多数亚组中,各 modality 间敏感度、PPV和AUC差异P<.05。
核心结论
- 在全女性人群中,FFDM对乳腺癌的判别或预测能力优于SFM或CR,且不受年龄、乳腺密度或筛查轮次影响。
研究设计与样本
- 回顾性分析2011年1月1日至2013年12月31日全国乳腺癌筛查项目与全国癌症登记链接的数据库。
- 纳入8 482 803名40-79岁韩国女性(平均年龄55岁±10),其中34.4%(2 920 279/8 482 803)接受SFM,51.7%(4 385 807/8 482 803)接受CR,13.9%(1 176 717/8 482 803)接受FFDM。
- 计算敏感度、特异度、PPV及绝对和相对差异,并进行多重检验校正的两两比较;AUC采用DeLong法结合Bonferroni校正比较。
诊断标准与关键数值
- FFDM较SFM的敏感度调整OR为1.77(95%CI:1.62,1.95),PPV调整OR为1.36(95%CI:1.29,1.43)。
- FFDM较CR的敏感度调整OR为1.70(95%CI:1.56,1.85),PPV调整OR为1.26(95%CI:1.20,1.32)。
- FFDM总体AUC为0.80(95%CI:0.80,0.81),高于SFM的0.75(95%CI:0.75,0.76)和CR的0.76(95%CI:0.75,0.76)。
- FFDM特异度低于SFM和CR。
- 各 modality 间敏感度、PPV和AUC差异总体及年龄、乳腺密度、筛查轮次多数亚组中P<.05。
临床应用与阅片要点
- 原文结论指出FFDM在全女性人群中对乳腺癌的判别或预测优于SFM或CR,不受年龄、乳腺密度或筛查轮次影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Full-field digital mammography (FFDM) has been accepted as a superior modality for breast cancer screening compared with conventional screen-film mammography (SFM), especially in women younger than 50 years or with dense breasts. Purpose To evaluate the accuracy of FFDM for breast cancer screening. Materials and Methods Data from January 1, 2011 to December 31, 2013 in the database from a nationwide breast cancer screening program linked with the national cancer registry were retrospectively analyzed. The study included Korean women aged 40-79 years who had undergone screening mammography with SFM, computed radiography (CR), or FFDM. The sensitivity, specificity, positive predictive value (PPV), and absolute and relative differences among these modalities were calculated, followed by pairwise comparison tests with multiple testing corrections. The areas under the receiver operating characteristic curve (AUCs) were also estimated and compared by using the DeLong method with Bonferroni correction. Results Among the 8 482 803 women included (mean age, 55 years ± 10), 34.4% (2 920 279 of 8 482 803), 51.7% (4 385 807 of 8 482 803), and 13.9% (1 176 717 of 8 482 803) underwent SFM, CR, and FFDM, respectively. The sensitivity and PPV were higher for FFDM than for SFM (adjusted odds ratio, 1.77 [95% confidence interval {CI}: 1.62, 1.95] for sensitivity and 1.36 [95% CI: 1.29, 1.43] for PPV) and CR (adjusted odds ratio, 1.70 [95% CI: 1.56, 1.85] for sensitivity and 1.26 [95% CI: 1.20, 1.32] for PPV), whereas specificity was lower with FFDM. The overall AUC for FFDM was 0.80 (95% CI: 0.80, 0.81), which was higher than that for SFM (0.75 [95% CI: 0.75, 0.76]) and CR (0.76 [95% CI: 0.75, 0.76]). P < .05 was found for differences in sensitivity, PPV, and AUC among modalities overall and in most of the subgroups of age, breast density, and screening round. Conclusion Full-field digital mammography allows better discrimination or prediction of breast cancer in the general female population than screen-film mammography or computed radiography, regardless of age, breast density, or screening round. © RSNA, 2019 Online supplemental material is available for this article.
引用
- Hong S, Song SY, Park B, et al. Effect of Digital Mammography for Breast Cancer Screening: A Comparative Study of More than 8 Million Korean Women. Radiology. 2019. PMID: 31793847. doi:10.1148/radiol.2019190951
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。