乳腺磁共振成像评估纯导管原位癌肿瘤范围:全诊断方案与简化方案的比较
回顾性纳入164例病理证实的纯导管原位癌患者,两位放射科医师分别用简化方案(AP)和全诊断方案(FDP)评估肿瘤范围并与病理对照。FDP与病理的测值差异显著小于AP(p<0.001),FDP相关性更高,但AP的读者间变异更小。结论提示FDP术前MRI评估纯DCIS肿瘤范围比AP更准确。
要点
- 全诊断方案(FDP)测量的肿瘤范围与病理差异显著小于简化方案(AP)(p<0.001)。
- FDP与病理的相关性高于AP(读者1:0.65 vs 0.63;读者2:0.73 vs 0.69)。
- FDP的读者间测值变异大于AP,且B3病变、低级别DCIS和中/显著BPE会降低MRI与病理的一致性。
核心结论
- FDP术前MRI评估纯DCIS肿瘤范围比单独AP更准确,表现为FDP与病理测值差异显著更小(p<0.001)。
研究设计与样本
- 回顾性研究纳入164例病理证实的纯DCIS患者,均行术前乳腺MRI。
- 两位放射科医师独立在FDP(含延迟期)和AP(不含延迟期)上评估肿瘤范围,并与病理肿瘤范围比较。
- 同时评估背景实质强化(BPE)和形态,并分析BPE程度、B2/B3病变有无及DCIS病理分级对MRI准确性的影响;一致性用相关分析评估。
关键影像表现/征象
- 原文未报告具体影像征象。
诊断标准与关键数值
- MRI与病理肿瘤范围的一致性:AP的Spearman秩相关系数读者1为0.63、读者2为0.69。
- FDP的Spearman秩相关系数读者1为0.65、读者2为0.73。
- 两位读者FDP与病理的测值差异均显著小于AP与病理的差异(p<0.001)。
- FDP的读者间肿瘤范围测值变异大于AP。
- B3病变、低级别DCIS和中/显著BPE会降低MRI与病理的一致性率。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the rate of concordance between pathology and preoperative breast MRI performed with an abbreviated protocol (AP) or a full diagnostic protocol (FDP) for estimation of the tumour extent in patients with pure ductal carcinoma in situ (DCIS).
METHODS: This retrospective study included 164 patients with pathologically proven DCIS who underwent preoperative breast MRI. Two radiologists independently evaluated the tumour extent on MRI with (FDP) and without the delayed phase (AP) and compared the readings with the pathological tumour extent. The background parenchymal enhancement (BPE) and morphology were also evaluated. Furthermore, the influence of the degree of BPE, presence or absence of B2 and B3 lesions, and pathological DCIS grade on the accuracy of MRI findings was assessed. Concordance between MRI and pathology was evaluated using correlation analysis.
RESULTS: Spearman's rank correlation coefficients for the concordance between MRI and pathology were 0.63 (reader 1) and 0.69 (reader 2) with AP and 0.65 and 0.73 (readers 1 and 2, respectively) with FDP. For both readers, the difference in the measured value between FDP and pathology was significantly smaller than that between AP and pathology (p < 0.001). The inter-reader variation in the measured tumour extent was larger with FDP than with AP. The presence of B3 lesions, low-grade DCIS, and moderate/marked BPE lowered the rate of concordance between MRI and pathology.
CONCLUSIONS: Our findings suggest that preoperative MRI with FDP is more accurate than that with AP alone for estimation of the tumour extent in patients with pure DCIS.