文献速递妇产影像介入USMR

超声引导在晚期宫颈癌宫旁治疗中的临床应用

Clinical Application of Ultrasound Guidance for Parametrial Treatment of Advanced Cervical Cancer.
PubMed 文献 · J Ultrasound Med · 2019-12-11

本研究纳入2017年2月至2019年2月因宫颈癌接受宫旁植入近距离放疗的患者,比较超声与MRI在确定宫旁植入物位置中的准确性。以宫颈横断面(S1)和宫颈外口上方1 cm横断面(S2)为观察平面,测量子宫钛针与子宫管/植入器之间的距离(MRI为M1–M4,超声为D1–D4)。各组M与D差异均无统计学意义,组内相关系数为0.970、0.968、0.952、0.956,回归分析显示M与D呈线性关系。结论认为超声能准确确定宫旁植入针位置,可用于晚期宫颈癌宫旁近距离放疗的辅助。

要点

  • 超声与MRI测量宫旁植入针距离在各组间差异均无统计学意义(P=.058、.821、.870、.936)。
  • 超声与MRI测值的组内相关系数为0.970、0.968、0.952、0.956,一致性高。
  • 超声可准确确定宫旁植入针位置,有助于晚期宫颈癌宫旁近距离放疗。

核心结论

  • 在宫颈癌宫旁近距离放疗中,超声能准确确定宫旁植入针的位置,该定位已可应用MRI,并可为晚期宫颈癌宫旁近距离放疗提供辅助。

研究设计与样本

  • 研究纳入2017年2月至2019年2月因宫颈癌接受宫旁植入近距离放疗的患者。
  • 选取宫颈横断面(S1)和宫颈外口上方1 cm横断面(S2)作为MRI与超声的观察平面。
  • 在MRI观察平面测量子宫钛针与子宫管/植入器之间的距离,设为M1至M4;在超声观察平面测量子宫钛针与子宫管/植入器之间的距离,设为D1至D4。
  • 比较各组M与D的差异和一致性。

诊断标准与关键数值

  • 各组M与D差异均无统计学意义(P=.058、P=.821、P=.870、P=.936)。
  • 各组M与D的组内相关系数分别为0.970、0.968、0.952、0.956。
  • 回归分析显示各组M与D的关系为:M1=0.9449D1+0.1812;M2=0.9463D2+0.0965;M3=0.9176D3+0.1233;M4=0.9253D4+0.1224。

临床应用与阅片要点

  • 在晚期宫颈癌宫旁近距离放疗中,可用超声确定宫旁植入针的位置,作为MRI定位的辅助手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the accuracy of ultrasound (US) in determining the positions of parametrial implants by comparing US with magnetic resonance imaging (MRI) for advanced cervical cancer.

METHODS: Patients undergoing brachytherapy with parametrial implantation for cervical cancer from February 2017 to February 2019 were involved in the study. The transverse section of the cervix (surface S1 ) and the transverse section 1 cm above the external cervix (surface S2 ) were selected from MRI and US images as the observation planes. In the MRI observation plane, the distances between the uterine titanium needles and the uterine tube/implanter were set as M1 to M4 ; in the US observation plane, the distances between the uterine titanium needles and the uterine tube/implanter were set as D1 to D4 . The differences and consistency in M and D of each group were then compared.

RESULTS: There were no significant differences between M and D in each group (P = .058; P = .821; P = .870; and P = .936, respectively). The intraclass correlation coefficients of M and D in each group were 0.970, 0.968, 0.952, and 0.956. A regression analysis showed that the relationships between M and D in each group were as follows: M1 = 0.9449D1 + 0.1812; M2 = 0.9463D2 + 0.0965; M3 = 0.9176D3 + 0.1233; and M4 = 0.9253D4 + 0.1224.

CONCLUSIONS: In parametrial brachytherapy for cervical cancer, US can accurately determine the positions of parametrial implantation needles, which is already applicable on MRI, and can provide assistance in parametrial brachytherapy for advanced cervical cancer.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Lin Y, Cheng G, Shi D, et al. Clinical Application of Ultrasound Guidance for Parametrial Treatment of Advanced Cervical Cancer. J Ultrasound Med. 2019. PMID: 31825130. doi:10.1002/jum.15189

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。