低能级虚拟单色图像在快速kV切换双能CT评估胰腺导管腺癌中的价值
前瞻性纳入74例胰腺导管腺癌患者行动态增强双能CT,比较40至75 keV八个能级虚拟单色图像。40 keV图像上胰腺信噪比、肿瘤-胰腺对比噪声比及肿瘤显示清晰度最高,且肿瘤大小测量可重复性更好,较高能级趋向于高估肿瘤大小。
要点
- 40 keV虚拟单色图像上胰腺导管腺癌与胰腺实质的CT衰减值、背景噪声、信噪比及对比噪声比均达峰值,随能级升高逐渐下降。
- 40 keV图像上肿瘤显示清晰度显著优于其他所有能级(p<0.0001)。
- 40 keV图像测量肿瘤长径的可重复性更好,较高能级趋向于高估肿瘤大小。
关键影像表现/征象
- 40 keV虚拟单色图像上胰腺导管腺癌和胰腺实质的CT衰减值、背景噪声、胰腺信噪比及肿瘤-胰腺对比噪声比均达峰值,随能级升高逐渐下降(p<0.0001)。
- 40 keV图像上肿瘤显示清晰度显著优于其他所有能级(p<0.0001)。
诊断标准与关键数值
- 40 keV图像上读者1和读者2测量的肿瘤长径分别为28.8 mm和29.2 mm,测量可重复性更好。
- 75 keV图像上读者1和读者2测量的肿瘤长径分别为29.8 mm和30.9 mm,较高能级趋向于高估肿瘤大小。
临床应用与阅片要点
- 在胰腺实质期观察胰腺导管腺癌时,可优先选择40 keV虚拟单色图像以提高肿瘤与胰腺实质的对比及肿瘤显示清晰度。
- 测量肿瘤大小时应注意较高能级虚拟单色图像可能高估肿瘤长径,40 keV图像测量可重复性更好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the value of virtual monochromatic images (VMIs) at lower energy levels in fast-voltage-switching dual-energy computed tomography (DECT) for assessing pancreatic ductal adenocarcinoma (PDAC).
MATERIALS AND METHODS: The institutional review board approved this prospective study. Written informed consent was obtained from all patients. Seventy-four consecutive patients with PDAC underwent dynamic contrast-enhanced DECT. Two radiologists reviewed eight energy levels (40, 45, 50, 55, 60, 65, 70, and 75 keV) of the pancreatic parenchymal phase VMIs. CT attenuation of the PDAC and pancreatic parenchyma, background noise, signal-to-noise ratio (SNR) of the pancreas, tumour-to-pancreas contrast-to-noise ratio (CNR), major and minor axes of PDAC, and qualitative tumour conspicuity were compared among the VMIs at eight energy levels.
RESULTS: CT attenuation of PDAC and pancreatic parenchyma, background noise, SNR, and CNR peaked on VMIs at 40 keV with statistically significant difference (p<0.0001) and gradually decreased with increasing energy levels. The reproducibility in measuring tumour size was better on VMIs at 40 keV (28.8 and 29.2 mm of major axis in readers 1 and 2, respectively) and tended to be overestimated at higher energy levels (29.8 and 30.9 mm of major axis at 75 keV in readers 1 and 2, respectively). Qualitative tumour conspicuity was also significantly superior on VMIs at 40 keV than at all other energy levels (p<0.0001).
CONCLUSION: VMIs at 40 keV demonstrated significantly increased SNR of the pancreas, CNR, and tumour conspicuity and high reproducibility in measuring tumour size for assessing PDAC.
引用
- Noda Y, Goshima S, Kaga T, et al. Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT. Clin Radiol. 2019. PMID: 31879024. doi:10.1016/j.crad.2019.11.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。