文献速递腹部MR

肝脏T1 mapping、T2 mapping与MR弹性成像用于肝纤维化检测与分期

T1 mapping, T2 mapping and MR elastography of the liver for detection and staging of liver fibrosis.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

本研究纳入223例已知或疑似肝病患者,行T1 mapping与2D SE-EPI MR弹性成像(MRE),其中139例另行T2 mapping。23例有肝活检的患者中,MRE鉴别早期(F0-F2)与进展期(F3-F4)纤维化的AUC为0.975(阅片者1)和0.925(阅片者2),优于T1 mapping与T2 mapping;MRE与T1/T2 mapping仅呈中度正相关,两者联合并不优于单用MRE。

要点

  • 23例肝活检患者中,MRE鉴别早期与进展期纤维化的AUC为0.975(阅片者1)和0.925(阅片者2)。
  • T1 mapping的AUC为0.671(阅片者1)和0.642(阅片者2),T2 mapping为0.671(阅片者1)和0.743(阅片者2)。
  • MRE与T1 mapping呈显著中度正相关(r=0.49和0.36),联合T1/T2 mapping并不优于单用MRE。

核心结论

  • 肝脏T1与T2 mapping与MR弹性成像呈中度正相关。
  • 在有肝活检的患者亚组中,MRE的准确性优于T1 mapping和T2 mapping。
  • MRE联合T1 mapping或T2 mapping的准确性并不优于单用MRE。

研究设计与样本

  • 研究纳入223例已知或疑似肝病患者,行肝脏MRI T1 mapping(Look-Locker序列)与2D SE-EPI MR弹性成像(MRE)序列。
  • 其中139例患者另行T2 mapping(径向T2 TSE序列)。
  • 两名阅片者(R1与R2)分别测量肝脏硬度、T1弛豫时间与T2弛豫时间。
  • 以23例接受肝活检患者的纤维化分期为参考标准,采用ROC分析比较两种技术的鉴别效能。

诊断标准与关键数值

  • 23例肝活检患者中,MRE鉴别早期(F0-F2)与进展期(F3-F4)纤维化的AUC为0.975(R1)和0.925(R2)。
  • T1 mapping鉴别早期(F0-F2)与进展期(F3-F4)纤维化的AUC为0.671(R1)和0.642(R2)。
  • T2 mapping鉴别早期(F0-F2)与进展期(F3-F4)纤维化的AUC为0.671(R1)和0.743(R2)。
  • MRE的阅片者间一致性良好(ICC=0.84),T1 mapping(ICC=0.94)与T2 mapping(ICC=0.96)的阅片者间一致性为高度一致。

临床应用与阅片要点

  • 在需鉴别早期(F0-F2)与进展期(F3-F4)肝纤维化时,MRE的ROC鉴别效能优于T1 mapping和T2 mapping。
  • MRE联合T1 mapping或T2 mapping的准确性并不优于单用MRE。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare liver stiffness measurements obtained from MR elastography with liver T1 relaxation times obtained from T1 mapping and T2 relaxation times obtained from T2 mapping for detection and staging of liver fibrosis.

MATERIALS AND METHODS: 223 patients with known or suspected liver disease underwent MRI of the liver with T1 mapping (Look-Locker sequence) and 2D SE-EPI MR elastography (MRE) sequences. 139 of these patients also underwent T2 mapping with radial T2 TSE sequence. Two readers (R1 & R2) measured liver stiffness, T1 relaxation times and T2 relaxation times. T1 and T2 times were correlated with stiffness measurements. ROC analysis was used to compare the performance of both techniques in discriminating fibrosis stage in 23 patients who underwent liver biopsy.

RESULTS: For each reader there was significant moderate positive correlation between liver MRE and liver T1 mapping (r = 0.49 and 0.36). There was significant moderate positive correlation between liver T2 mapping and each of MRE and T1 mapping for one of the readers (r = 0.40 and 0.27). AUC for differentiating early (F0-F2) from advanced (F3-F4) fibrosis in biopsied patients was 0.975 (R1) and 0.925 (R2) for MRE, 0.671 (R1) and 0.642 (R2) for T1 mapping and 0.671 (R1) and 0.743 (R2) for T2 mapping. Inter-reader agreement was good for MRE (ICC = 0.84) substantial for T1 mapping (0.94) and T2 mapping (0.96).

CONCLUSIONS: Liver T1 and T2 mapping showed moderate positive correlation with MR elastography. Accuracy of MRE is however superior to T1 and T2 mapping in the subset of patients who underwent liver biopsy. Accuracy of combination of MRE and T1 mapping/T2 mapping was not superior to MRE alone.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Hoffman DH, Ayoola A, Nickel D, et al. T1 mapping, T2 mapping and MR elastography of the liver for detection and staging of liver fibrosis. Abdom Radiol (NY). 2020. PMID: 31875241. doi:10.1007/s00261-019-02382-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。