文献速递心血管CT

基于深度学习的优化算法对低剂量冠状动脉CT血管造影降噪后图像质量的影响:一项前瞻性研究

Impact of Deep Learning-based Optimization Algorithm on Image Quality of Low-dose Coronary CT Angiography with Noise Reduction: A Prospective Study.
PubMed 文献 · Acad Radiol · 2019-12-19

前瞻性研究将70例接受冠状动脉CT血管造影(CCTA)的受试者随机分为80 kVp研究组A和100 kVp对照组B,并对A组图像进行深度学习(DL)优化得到C组。DL优化后C组主观图像质量评分显著优于A组,噪声显著降低,信噪比和对比噪声比显著升高;C组与B组噪声和信噪比无显著差异,但C组对比噪声比显著高于B组。DL算法处理速度约为迭代重建的两倍。

要点

  • 低剂量80 kVp CCTA经DL优化后,主观图像质量评分显著优于未优化图像(p=0.005)。
  • DL优化后C组噪声较A组显著降低,SNR和CNR显著升高(p<0.001)。
  • C组与100 kVp B组噪声和SNR无显著差异,但C组CNR显著高于B组(p<0.05)。

核心结论

  • 基于DL的优化算法可通过降噪有效改善低剂量CCTA的图像质量。

研究设计与样本

  • 由两名经验丰富的放射科医生以四分法(4分优,1分差)对主观图像质量进行盲法评分,并计算噪声、信噪比(SNR)和对比噪声比(CNR)进行客观评价。
  • 记录迭代重建与DL算法处理时间的差异。

诊断标准与关键数值

  • 主观图像质量采用四分法评分:4分为优,1分为差。
  • C组主观图像质量评分显著优于A组(p=0.005);A组主观评分低于B组(p=0.037);C组与B组主观评分无显著差异(p=0.874)。
  • C组噪声较A组显著降低,SNR和CNR较A组显著升高(p<0.001);A组噪声显著高于B组,SNR和CNR显著低于B组(p<0.05)。
  • C组与B组噪声和SNR无显著差异(p>0.05),但C组CNR显著高于B组(p<0.05)。

临床应用与阅片要点

  • DL优化算法处理图像的速度约为迭代重建的两倍。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate deep learning (DL)-based optimization algorithm for low-dose coronary CT angiography (CCTA) image noise reduction and image quality (IQ) improvement.

MATERIALS AND METHODS: A postprocessing platform for the CCTA image was built using a DL-based algorithm. Seventy subjects referred for CCTA were randomly divided into two groups (study group A with 80 kVp and control group B with 100 kVp). Group C was obtained by DL optimization of group A. Subjective IQ was blindly graded by two experienced radiologists on a four-point scale (4-excellent,1-poor). The image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated to evaluate IQ objectively. The difference between the time consumed of iterative reconstruction and DL algorithm was also recorded.

RESULTS: The subjective IQ score of group C using the DL algorithm was significantly better than that of group A (p = 0.005). The noise of group C was significantly decreased, while SNR and CNR were significantly increased compared to group A (p < 0.001). The subjective IQ scores were lower in group A compared to group B (p = 0.037), whereas subjective IQ scores in group C were not significantly different (p = 0.874). For objective IQ, the noise of group A was significantly higher, while SNR and CNR were significantly lower than that of group B (p < 0.05). There was no significant difference in noise and SNR between group C and group B (p > 0.05), but CNR in group C was significantly higher than that in group B (p < 0.05). The DL algorithm processes the image twice as fast as the iterative reconstruction speed.

CONCLUSION: The DL-based optimization algorithm could effectively improve the IQ of low-dose CCTA by noise reduction.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Liu P, Wang M, Wang Y, et al. Impact of Deep Learning-based Optimization Algorithm on Image Quality of Low-dose Coronary CT Angiography with Noise Reduction: A Prospective Study. Acad Radiol. 2019. PMID: 31864809. doi:10.1016/j.acra.2019.11.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。