文献速递心血管CT

冠心病「一站式」心肌CT灌注成像中应用16厘米宽探测器CT实现低辐射剂量的可行性研究

Achieving Low Radiation Dose in "One-Stop" Myocardial Computed Tomography Perfusion Imaging in Coronary Artery Disease Using 16-cm Wide Detector CT.
PubMed 文献 · Acad Radiol · 2019-12-17

442例疑似冠心病患者随机分为两组,A组行「一站式」心肌CT灌注成像(联合解剖、灌注和功能),B组行常规冠状动脉CT血管成像。A组扫描时间较B组延长73.1±7.3秒,辐射剂量降低11.7%(p<0.001),图像质量无显著差异。A组按冠状动脉狭窄程度分四个亚组,最小透壁灌注比(F=24.657,p<0.001)和左心室射血分数(χ2=36.98,p<0.001)组间差异显著;冠状动脉狭窄程度与对应心肌节段透壁灌注比呈负相关(r=-0.55,p<0.001);中重度狭窄患者左心室射血分数低于正常冠状动脉者(48.0% vs 56.5%,p<0.001)。

要点

  • 「一站式」心肌CT灌注成像较常规冠状动脉CT血管成像辐射剂量降低11.7%,图像质量无显著差异。
  • 冠状动脉狭窄程度与对应心肌节段透壁灌注比呈负相关(r=-0.55,p<0.001)。
  • 中重度狭窄患者左心室射血分数低于正常冠状动脉者(48.0% vs 56.5%,p<0.001)。

研究设计与样本

  • 随机对照研究,442例疑似冠状动脉疾病患者随机分为两组。
  • A组行「一站式」心肌CT灌注成像(联合解剖、灌注和功能),B组行常规冠状动脉CT血管成像。
  • 使用16厘米宽探测器CT,评估CT图像质量,记录辐射剂量、对比剂剂量和扫描时间。
  • A组进一步按冠状动脉狭窄程度分为四个亚组,测量透壁灌注比和左心室射血分数。

关键影像表现/征象

  • A组扫描时间较B组延长73.1±7.3秒。
  • A组辐射剂量较B组降低11.7%(p<0.001),两组图像质量无显著差异。
  • A组四个狭窄程度亚组间最小透壁灌注比差异显著(F=24.657,p<0.001)。
  • A组四个狭窄程度亚组间左心室射血分数差异显著(χ2=36.98,p<0.001)。
  • 中重度动脉狭窄患者左心室射血分数低于正常冠状动脉者(48.0% vs 56.5%,p<0.001)。

诊断标准与关键数值

  • 冠状动脉狭窄程度与对应心肌节段透壁灌注比呈负相关(r=-0.55,p<0.001)。
  • A组按冠状动脉狭窄程度分为四个亚组,最小透壁灌注比组间比较F=24.657,p<0.001。
  • A组按冠状动脉狭窄程度分为四个亚组,左心室射血分数组间比较χ2=36.98,p<0.001。

临床应用与阅片要点

  • 「一站式」心肌CT灌注成像可同时评估心肌灌注、冠状动脉狭窄和左心室功能,较常规冠状动脉CT血管成像辐射剂量降低11.7%。
  • 扫描时间较常规冠状动脉CT血管成像延长73.1±7.3秒,需在流程中考虑时间成本。
  • 冠状动脉狭窄程度与对应心肌节段透壁灌注比呈负相关(r=-0.55,p<0.001),阅片时可结合两者评估。
  • 中重度狭窄患者左心室射血分数低于正常冠状动脉者(48.0% vs 56.5%,p<0.001),提示功能评估的价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate the feasibility of "one-stop" myocardial computed tomography perfusion (CTP) imaging (combined anatomy, perfusion, and function) in coronary artery disease using 16-cm wide detector CT, compared to conventional coronary CT angiography (CCTA).

MATERIALS AND METHODS: 442 patients with suspected coronary artery disease were randomly divided into two groups. Patients in group A underwent "one-stop" CTP, whereas group B underwent conventional CCTA. Image quality of CT images was assessed. Radiation and contrast medium doses and scan time of the two groups were recorded. Group A was further divided into four subgroups according to the degree of coronary artery stenosis, for which transmural perfusion ratio (TPR) and left ventricular ejection fraction (LVEF) were measured.

RESULTS: Scan time was 73.1 ± 7.3 (s) longer in group A than in group B with 11.7% reduction of radiation dose (p < 0.001) and no significant difference in image quality was noted. Significant differences regarding the minimum TPR (F = 24.657, p < 0.001) and LVEF (χ2 =36.98, p < 0.001) were observed among four subgroups. A negative correlation was found between the degree of coronary artery stenosis and TPR of the corresponding myocardial segments (r = -0.55, p < 0.001). Patients with moderate to severe arterial stenosis exhibited a decreased LVEF compared to those with normal coronary arteries (48.0% vs 56.5%, p < 0.001).

CONCLUSION: Compared to conventional CCTA, our new developed "one-stop" CTP may provide more comprehensive information on myocardial perfusion, coronary artery stenosis, and LV cardiac function with reduced radiation and contrast medium doses.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Liu K, Diao K, Hu S, et al. Achieving Low Radiation Dose in "One-Stop" Myocardial Computed Tomography Perfusion Imaging in Coronary Artery Disease Using 16-cm Wide Detector CT. Acad Radiol. 2019. PMID: 31859211. doi:10.1016/j.acra.2019.11.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。