冠状动脉CT血管成像斑块标志物与有创瞬时无波形比值相关用于检测血流动力学显著冠状动脉狭窄
前瞻性研究纳入39例疑似冠心病患者,采用低剂量第三代双源CT行冠状动脉CT血管成像并测量多种斑块标志物,以有创瞬时无波形比值(iFR)为参考标准评估54处血管特异性病变。iFR≤0.89判定15处(28%)病变为血流动力学显著;LL/MLD4的AUC为0.84,高于MLA(0.82)、MLD(0.81)、管腔直径狭窄程度(0.81)、CCO(0.79)、RI(0.75)和%APV(0.72)。结论认为上述斑块标志物可支持检测血流动力学显著狭窄,其中LL/MLD4判别力最强。
要点
- 以有创iFR≤0.89为参考,cCTA-derived LL/MLD4的AUC为0.84,在所列斑块标志物中判别力最高。
- MLA、MLD、管腔直径狭窄程度、CCO、RI和%APV的AUC分别为0.82、0.81、0.81、0.79、0.75和0.72。
- LL、VV、TPV、CPV和NCPV未达统计学显著,无法区分有无缺血性狭窄的血管。
核心结论
- cCTA-derived LL/MLD4、MLA、MLD、管腔直径狭窄程度、CCO、RI和%APV可支持检测血流动力学显著冠状动脉狭窄(以iFR为参考),其中LL/MLD4判别力最强。
研究设计与样本
- 前瞻性研究,纳入疑似冠心病患者39例(66.6±12.0岁,72%男性),采用低剂量第三代双源CT行cCTA,并以有创冠状动脉造影联合iFR测量为参考标准。
- 共分析54处血管特异性病变,其中15处(28%)经iFR≤0.89判定为血流动力学显著。
关键影像表现/征象
- cCTA上评估的斑块标志物包括LL/MLD4、MLA、MLD、管腔直径狭窄程度、CCO、RI、%APV、LL、VV、TPV、CPV和NCPV。
- LL、VV、TPV、CPV和NCPV在有无缺血性狭窄的血管间未达统计学显著,无法区分。
诊断标准与关键数值
- 参考标准为有创iFR≤0.89判定血流动力学显著狭窄,54处病变中15处(28%)符合。
- LL/MLD4的AUC为0.84,高于MLA(0.82)、MLD(0.81)、管腔直径狭窄程度(0.81)、CCO(0.79)、RI(0.75)和%APV(0.72)。
临床应用与阅片要点
- 原文结论认为cCTA-derived LL/MLD4、MLA、MLD、管腔直径狭窄程度、CCO、RI和%APV可支持检测血流动力学显著冠状动脉狭窄,其中LL/MLD4判别力最强。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The study aimed to compare morphological and anatomic plaque markers derived from coronary computed tomography angiography (cCTA) for the detection of lesion specific ischemia with invasive instantaneous wave free ratio (iFR®) as the reference standard.
METHODS: In our prospective study, we enrolled patients with suspected coronary artery disease (CAD), who had undergone cCTA, using a low-dose third-generation dual-source CT and invasive coronary angiography (ICA) with iFR® measurement. Various plaque markers were assessed on cCTA. Discriminatory power of these markers for the detection of ischemia-inducing coronary artery disease was evaluated against invasive iFR®.
RESULTS: Our study cohort included 39 patients (66.6 ± 12.0 years, 72 % male). Among 54 vessel-specific lesions, 15 lesions (28 %) were characterized as hemodynamically significant by iFR® ≤0.89. The area under the curve (AUC) of lesion length/ minimal luminal diameter4 (LL/MLD4) (0.84) was greater than the AUC of minimal luminal area (MLA) (0.82), MLD (0.81), the degree of luminal diameter stenosis (0.81), corrected coronary opacification (CCO) (0.79), remodeling index (RI) (0.75), and percentage aggregate plaque volume (%APV) (0.72). LL, vessel volume (VV), total plaque volume (TPV), calcified and non-calcified plaque volume (CPV and NCPV) did not reach statistical significance and were unable to discriminate between vessels with and without ischemia-inducing coronary stenosis.
CONCLUSION: LL/MLD4, MLA, MLD, the degree of luminal diameter stenosis, CCO, RI, and %APV derived from cCTA can support the detection of hemodynamically significant coronary stenosis as compared with iFR®, with LL/MLD4 showing the greatest discriminatory power.
引用
- Baumann S, Özdemir GH, Tesche C, et al. Coronary CT angiography derived plaque markers correlated with invasive instantaneous flow reserve for detecting hemodynamically significant coronary stenoses. Eur J Radiol. 2019. PMID: 31790934. doi:10.1016/j.ejrad.2019.108744