合成心电图与患者自身心电图门控320排儿童心脏CT的图像质量比较
回顾性纳入60例3岁以下先天性心脏病患儿的320排心脏CT,30例用患儿自身心电图门控、30例用150次/分合成心电图门控,比较图像质量。结果显示合成心电图门控在显示各解剖结构、线束硬化伪影及整体图像质量上不劣于患者自身心电图,但中远段冠状动脉的主观图像质量除外。
要点
- 合成心电图门控与患者自身心电图门控在显示心脏大血管结构方面图像质量不劣。
- 中远段冠状动脉的主观图像质量未达临床可接受水平。
- 合成心电图门控可避免为儿童心脏CT放置电极。
核心结论
- 3岁以下先天性心脏病患儿使用150次/分合成心电图门控行320排心脏CT,图像质量不劣于患者自身心电图门控。
研究设计与样本
- 回顾性研究,纳入60例3岁以下先天性心脏病患儿的320排心脏CT检查,其中30例用患儿自身心电图门控、30例用150次/分合成心电图门控。
诊断标准与关键数值
- 采用3分量表评估房间隔、室间隔、右心房、右心室、左心房、左心室、主肺动脉、升主动脉、主动脉弓(含动脉导管未闭)、降主动脉、右冠状动脉及左主干等结构的显示。
- 采用3分量表评估对比剂线束硬化伪影,采用5分量表评估整体图像质量。
- 合成心电图门控在显示各结构、线束硬化伪影及整体图像质量方面不劣于患者自身心电图。
- 平均各项指标达到临床可接受的图像质量,但中远段冠状动脉的主观图像质量除外。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Pediatric cardiac computed tomography (CT) can be acquired without electrode placement by using synthetic electrocardiogram (ECG).
OBJECTIVE: To determine whether the depiction of gross cardiac structures and coronary arteries in 320-row pediatric CT is not inferior when CT is gated with synthetic ECG at 150 beats per minute (bpm), compared to the patients' own ECG.
MATERIALS AND METHODS: Sixty 320-row CT examinations performed in children younger than 3 years old with congenital cardiac anomaly were enrolled in this retrospective study. Thirty examinations were scanned using the children's own ECG for gating and 30 examinations were scanned using synthetic ECG at 150 bpm. The image quality was compared between the two gating modes using a 3-point scale to delineate the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. Beam-hardening artifacts from contrast enhancement material were evaluated using a 3-point scale, and the overall image quality was evaluated using a 5-point scale.
RESULTS: Synthetic ECG was not inferior to the patients' ECG in depicting each structure, beam-hardening artifact and overall image quality. Average indices were clinically acceptable imaging quality, except for subjective image quality of mid and distal coronary arteries.
CONCLUSION: Pediatric cardiac CT in patients younger than 3 years old can be acquired using synthetic ECG gating, with image quality not inferior to the patients' ECG.
引用
- Maeda E, Shirota G, Shibata E, et al. Comparison of image quality between synthetic and patients' electrocardiogram-gated 320-row pediatric cardiac computed tomography. Pediatr Radiol. 2019. PMID: 31853572. doi:10.1007/s00247-019-04541-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。