文献速递心血管CT

双源双能CT噪声优化虚拟单能成像改善冠状动脉对比增强

Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography.
PubMed 文献 · Eur J Radiol · 2019-09-14

本研究对51例双能冠状动脉CTA数据分别重建标准线性融合图像、传统虚拟单能成像(VMI)和噪声优化虚拟单能成像(VMI+),在40至100 keV范围内评估图像质量。结果显示40 keV VMI+的客观信噪比和对比噪声比最高,主观血管对比度、图像锐利度、噪声及斑块勾勒评分也最优。

要点

  • 40 keV VMI+重建的客观图像质量优于70 keV VMI和标准融合图像。
  • 40 keV VMI+在血管对比度、图像锐利度、噪声和斑块勾勒方面主观评分最高。
  • 双能冠状动脉CTA可采用40 keV噪声优化虚拟单能成像重建改善图像质量。

核心结论

  • 双能冠状动脉CTA采用40 keV VMI+重建可显著改善客观和主观图像质量。

研究设计与样本

  • 研究纳入51例双能冠状动脉CTA数据集(33名男性,平均年龄63.9±13.2岁),重建标准线性融合图像(F_0.6;60%的90 kVp与40%的150 kVpSn)、传统VMI和噪声优化VMI+(40至100 keV,间隔10 keV)。

诊断标准与关键数值

  • 客观图像质量以信噪比(SNR)和对比噪声比(CNR)评估,VMI+在40 keV的SNR中位数为44.5、CNR为33.5,优于VMI在70 keV的SNR 28.1、CNR 18.4和标准F_0.6的SNR 23.2、CNR 15.6(均p<0.001)。
  • 主观评分中40 keV VMI+的血管对比度评分为5(ICC 0.90)、图像锐利度为4(ICC 0.88)、噪声为4(ICC 0.82)、斑块勾勒为5(ICC 0.89),均优于70 keV VMI和F_0.6图像(均p<0.001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA).

METHOD: Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ± 13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques.

RESULTS: Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR: 33.5), significantly superior (allp < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaque delineation (5; 0.89).

CONCLUSIONS: DE-CCTA image reconstruction with 40-keV VMI + allows for significant improvement of both objective and subjective image quality.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Arendt CT, Czwikla R, Lenga L, et al. Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography. Eur J Radiol. 2019. PMID: 31786506. doi:10.1016/j.ejrad.2019.108666

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。