左心房容积作为常规胸部CT心房颤动的生物标志物:深度学习方法
回顾性研究纳入500例连续患者训练深度学习模型测量左心房容积,并在另500例验证队列中评估其对心房颤动的预测能力。自动分割与人工分割重叠度良好(平均Dice=0.87),验证队列中左心房容积预测心房颤动的AUC=0.768,年龄校正相对风险为2.9,为独立预测因子。深度学习适用于自动测量。
要点
- 常规非门控胸部CT上左心房容积是心房颤动的独立预测因子,年龄校正相对风险2.9。
- 深度学习自动测量左心房容积的验证队列AUC=0.768,可作为机会性筛查工具。
- 自动与人工分割一致性良好(平均Dice=0.87),且略高于人工观察者间一致性(P=.004)。
核心结论
- 左心房容积是常规非门控胸部CT上心房颤动状态的独立预测因子,深度学习是自动测量的适用工具。
研究设计与样本
- 回顾性推导队列500例连续患者(平均年龄64岁,51%女性)用于训练深度学习模型测量左心房容积。
- 独立验证队列500例患者(平均年龄61岁,46%女性),心房颤动状态通过病历回顾确定。
- 采用受试者工作特征曲线分析评估自动心房尺寸对心房颤动的预测性能。
诊断标准与关键数值
- 自动与人工分割图在重叠度和表面距离指标上一致性良好:平均Dice=0.87,交并比=0.77,Hausdorff距离=4.36 mm,平均对称表面距离=0.96 mm。
- 自动分割与人工观察者间一致性比较:平均Dice自动0.85 vs 人工0.84,差异有统计学意义(P=.004)。
- 验证队列中左心房容积预测心房颤动的受试者工作特征曲线下面积=0.768。
- 左心房容积是心房颤动的独立预测因子,年龄校正相对风险为2.9。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To test the performance of a deep learning (DL) model in predicting atrial fibrillation (AF) at routine nongated chest CT.
MATERIALS AND METHODS: A retrospective derivation cohort (mean age, 64 years; 51% female) consisting of 500 consecutive patients who underwent routine chest CT served as the training set for a DL model that was used to measure left atrial volume. The model was then used to measure atrial size for a separate 500-patient validation cohort (mean age, 61 years; 46% female), in which the AF status was determined by performing a chart review. The performance of automated atrial size as a predictor of AF was evaluated by using a receiver operating characteristic analysis.
RESULTS: There was good agreement between manual and model-generated segmentation maps by all measures of overlap and surface distance (mean Dice = 0.87, intersection over union = 0.77, Hausdorff distance = 4.36 mm, average symmetric surface distance = 0.96 mm), and agreement was slightly but significantly greater than that between human observers (mean Dice = 0.85 [automated] vs 0.84 [manual]; P = .004). Atrial volume was a good predictor of AF in the validation cohort (area under the receiver operating characteristic curve = 0.768) and was an independent predictor of AF, with an age-adjusted relative risk of 2.9.
CONCLUSION: Left atrial volume is an independent predictor of the AF status as measured at routine nongated chest CT. Deep learning is a suitable tool for automated measurement.© RSNA, 2019See also the commentary by de Roos and Tao in this issue.
引用
- Bratt A, Guenther Z, Hahn LD, et al. Left Atrial Volume as a Biomarker of Atrial Fibrillation at Routine Chest CT: Deep Learning Approach. Radiol Cardiothorac Imaging. 2019. PMID: 33778529. doi:10.1148/ryct.2019190057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。