FDG PET/CT在实性部分≤3 cm的亚实性结节型非小细胞肺癌术前分期中的效用
回顾性纳入855例CT上表现为实性部分≤3 cm的亚实性结节、病理证实为非小细胞肺癌的患者,比较FDG PET/CT与胸部CT检测淋巴结、胸腔内或远处转移的诊断效能。FDG PET/CT对淋巴结分期的敏感度44.0%、特异度81.5%、准确率79.9%,准确率低于胸部CT(p<0.0001),且未能准确检出任何胸腔内或远处转移。结论认为FDG PET/CT在此类患者术前检测淋巴结或远处转移的效用有限。
要点
- 实性部分≤3 cm的亚实性非小细胞肺癌淋巴结转移率低(765例中25例,3.3%)。
- FDG PET/CT淋巴结分期准确率79.9%,低于胸部CT(p<0.0001)。
- FDG PET/CT未能准确检出任何胸腔内或远处转移(855例中2例,0.2%)。
核心结论
- FDG PET/CT在实性部分≤3 cm的亚实性非小细胞肺癌患者术前检测淋巴结或远处转移的效用有限。
研究设计与样本
- 回顾性纳入855例病理证实的非小细胞肺癌患者,CT上表现为亚实性结节且实性部分≤3 cm。
- 比较术前行胸部CT和FDG PET/CT者的两种检查对淋巴结、胸腔内或远处转移的诊断效能。
- 经倾向性评分匹配后,比较行胸部CT+FDG PET/CT组中FDG PET/CT与未行FDG PET/CT组中胸部CT的诊断效能。
诊断标准与关键数值
- 淋巴结分期:FDG PET/CT敏感度44.0%、特异度81.5%、阳性预测值9.6%、阴性预测值97.0%、准确率79.9%,准确率低于胸部CT(p<0.0001)。
- 行手术淋巴结清扫或活检的765例中25例(3.3%)有淋巴结转移;855例中2例(0.2%)有胸腔内或远处转移。
- FDG PET/CT未能准确检出任何胸腔内或远处转移。
- 倾向性评分匹配后,FDG PET/CT(CT+PET/CT组)淋巴结分期准确率低于胸部CT(未行PET/CT组)(p=0.002),胸腔内和远处转移诊断准确率无差异(p>0.999)。
临床应用与阅片要点
- 原文结论认为FDG PET/CT在此类患者术前检测淋巴结或远处转移的效用有限。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The objective of our study was to investigate the utility of FDG PET/CT for the preoperative staging of subsolid non-small cell lung cancers (NSCLCs) with a solid portion size of 3 cm or smaller. MATERIALS AND METHODS. We retrospectively enrolled 855 patients with pathologically proven NSCLCs manifesting as subsolid nodules with a solid portion of 3 cm or smaller on CT. We then compared the diagnostic performances of FDG PET/CT and chest CT for detecting lymph node (LN), intrathoracic, or distant metastases in patients who underwent preoperative chest CT and FDG PET/CT. After propensity score matching, we compared the diagnostic performance of FDG PET/CT in the group who underwent both chest CT and FDG PET/CT with that of chest CT in patients who did not undergo FDG PET/CT. RESULTS. There were LN metastases in 25 of 765 patients (3.3%) who underwent surgical LN dissection or biopsy and intrathoracic or distant metastasis in two of 855 patients (0.2%). For LN staging, FDG PET/CT showed a sensitivity of 44.0%, specificity of 81.5%, positive predictive value of 9.6%, negative predictive value of 97.0%, and accuracy of 79.9%, which were lower than those of chest CT for accuracy (p < 0.0001). FDG PET/CT could not accurately detect any intrathoracic or distant metastasis. After propensity score matching, the diagnostic accuracy for LN staging of FDG PET/CT in the group who underwent both CT and FDG PET/CT was lower than that of chest CT in the group who did not undergo FDG PET/CT (p = 0.002), and the diagnostic accuracy for intrathoracic and distant metastases was not different (p > 0.999). CONCLUSION. FDG PET/CT has limited utility in preoperatively detecting LN or distant metastasis in patients with subsolid NSCLCs with a solid portion size of 3 cm or smaller.
引用
- Suh YJ, Park CM, Han K, et al. Utility of FDG PET/CT for Preoperative Staging of Non-Small Cell Lung Cancers Manifesting as Subsolid Nodules With a Solid Portion of 3 cm or Smaller. AJR Am J Roentgenol. 2019. PMID: 31846374. doi:10.2214/AJR.19.21811
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。