文献速递胸部技术与安全PETCT

人工智能检测数字PET/CT中小的FDG阳性肺结节:图像重建对诊断性能的影响

Artificial intelligence for detecting small FDG-positive lung nodules in digital PET/CT: impact of image reconstructions on diagnostic performance.
PubMed 文献 · Eur Radiol · 2019-12-10

该回顾性研究纳入57例患者的92个≤2 cm的18F-FDG高摄取肺结节,使用OSEM和BSREM重建的PET图像评估深度学习算法的检测性能。结果显示,BSREM重建的AUC为0.848,显著高于OSEM的0.796(p=0.001);每层灵敏度和特异度分别为OSEM 66.7%和79.0%,BSREM 69.2%和84.5%;每结节灵敏度OSEM为81.5%,BSREM为87.0%。结论提示机器学习算法可能有助于检测小的FDG高摄取肺结节,且BSREM图像上表现更优。

要点

  • BSREM重建可提高小肺结节的SUVmax,并提升AI检测的AUC和灵敏度。
  • AI检测每层灵敏度约66.7%~69.2%,每结节灵敏度约81.5%~87.0%。
  • 算法在BSREM图像上的AUC显著高于OSEM(0.848 vs 0.796,p=0.001)。

关键影像表现/征象

  • BSREM重建较OSEM重建产生更高的小肺结节SUVmax。
  • AI检测在BSREM图像上的每层灵敏度和特异度分别为69.2%和84.5%,OSEM为66.7%和79.0%。
  • AI检测在BSREM图像上的每结节灵敏度为87.0%,OSEM为81.5%。

诊断标准与关键数值

  • AI检测结节使用OSEM重建的AUC为0.796(95%CI 0.772-0.869)。
  • AI检测结节使用BSREM重建的AUC为0.848(95%CI 0.828-0.869),显著高于OSEM(p=0.001)。
  • 每层分析灵敏度/特异度:OSEM 66.7%/79.0%,BSREM 69.2%/84.5%。
  • 每结节分析总体灵敏度:OSEM 81.5%,BSREM 87.0%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic performance of a deep learning algorithm for automated detection of small 18F-FDG-avid pulmonary nodules in PET scans, and to assess whether novel block sequential regularized expectation maximization (BSREM) reconstruction affects detection accuracy as compared to ordered subset expectation maximization (OSEM) reconstruction.

METHODS: Fifty-seven patients with 92 18F-FDG-avid pulmonary nodules (all ≤ 2 cm) undergoing PET/CT for oncological (re-)staging were retrospectively included and a total of 8824 PET images of the lungs were extracted using OSEM and BSREM reconstruction. Per-slice and per-nodule sensitivity of a deep learning algorithm was assessed, with an expert readout by a radiologist/nuclear medicine physician serving as standard of reference. Receiver-operator characteristic (ROC) curve of OSEM and BSREM were assessed and the areas under the ROC curve (AUC) were compared. A maximum standardized uptake value (SUVmax)-based sensitivity analysis and a size-based sensitivity analysis with subgroups defined by nodule size was performed.

RESULTS: The AUC of the deep learning algorithm for nodule detection using OSEM reconstruction was 0.796 (CI 95%; 0.772-0.869), and 0.848 (CI 95%; 0.828-0.869) using BSREM reconstruction. The AUC was significantly higher for BSREM compared to OSEM (p = 0.001). On a per-slice analysis, sensitivity and specificity were 66.7% and 79.0% for OSEM, and 69.2% and 84.5% for BSREM. On a per-nodule analysis, the overall sensitivity of OSEM was 81.5% compared to 87.0% for BSREM.

CONCLUSIONS: Our results suggest that machine learning algorithms may aid detection of small 18F-FDG-avid pulmonary nodules in clinical PET/CT. AI performed significantly better on images with BSREM than OSEM.

KEY POINTS: • The diagnostic value of deep learning for detecting small lung nodules (≤ 2 cm) in PET images using BSREM and OSEM reconstruction was assessed. • BSREM yields higher SUVmaxof small pulmonary nodules as compared to OSEM reconstruction. • The use of BSREM translates into a higher detectability of small pulmonary nodules in PET images as assessed with artificial intelligence.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Schwyzer M, Martini K, Benz DC, et al. Artificial intelligence for detecting small FDG-positive lung nodules in digital PET/CT: impact of image reconstructions on diagnostic performance. Eur Radiol. 2019. PMID: 31822970. doi:10.1007/s00330-019-06498-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。