文献速递胸部CT

在R软件中创建肺部高分辨率计算机断层扫描的标准模板

Template Creation for High-Resolution Computed Tomography Scans of the Lung in R Software.
PubMed 文献 · Acad Radiol · 2019-12-13

本研究利用65例健康成人高分辨率CT,通过分割左右肺、非线性配准肺掩膜及无偏迭代流程,在R软件中构建标准肺模板(Dice相似系数≥0.99),并应用于结节病群体,探索配准对影像组学分析的影响;配准显著改变影像组学特征,并提高对组间差异的检测能力。

要点

  • 标准肺模板右肺体积2967 cm3、左肺体积2623 cm3,中位HU为-862。
  • 配准使HU分布左移、变异性降低、平滑度增加(p < 0.0001)。
  • 对比度、自相关、能量和同质性在配准后组效应显著(p < 0.05),配准前不显著。

关键影像表现/征象

  • 最终肺模板右肺体积为2967 cm3,左肺体积为2623 cm3,中位HU = -862。
  • 配准显著影响影像组学特征,使HU分布左移、变异性降低、平滑度增加(p < 0.0001)。

诊断标准与关键数值

  • 标准肺模板创建以Dice相似系数≥0.99为收敛标准。
  • 配准后,对比度、自相关、能量和同质性的组效应显著(p < 0.05);配准前这些特征的组效应不显著。

临床应用与阅片要点

  • 最终肺模板及创建软件通过lungct R包公开可用,便于实践使用。
  • 配准可提高影像组学对组间差异的检测能力,在分析前应考虑配准的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: A standard lung template could improve population-level analyses for computed tomography (CT) scans of the lung. We develop a fully automated preprocessing pipeline for image analysis of the lungs using updated methodologies and R software that results in the creation of a standard lung template. We apply this pipeline to CT scans from a sarcoidosis population, exploring the influence of registration on radiomic analyses.

MATERIALS AND METHODS: Using 65 high-resolution CT scans from healthy adults, we create a standard lung template by segmenting the left and right lungs, nonlinearly registering lung masks to an initial template mask, and using an unbiased, iterative procedure to converge to a standard lung shape (Dice similarity coefficient ≥0.99). We compare three-dimensional radiomic features between control and sarcoidosis patients, before and after registration to a study-specific lung template.

RESULTS: The final lung template had a right lung volume of 2967 cm3 and left lung volume of 2623 cm3, with a median HU = -862. Registration significantly affected radiomic features, shifting the HU distribution to the left, decreasing variability, and increasing smoothness (p < 0.0001). The registration improved detective ability of radiomics; for contrast, autocorrelation, energy, and homogeneity, the group effect was significant postregistration (p < 0.05), but was not significant preregistration.

CONCLUSION: The final lung template and software used for its creation are publicly available via the lungct R package to facilitate its use in practice. This study advances lung imaging by developing tools to improve population-level analyses for various lung diseases.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ryan SM, Vestal B, Maier LA, et al. Template Creation for High-Resolution Computed Tomography Scans of the Lung in R Software. Acad Radiol. 2019. PMID: 31843391. doi:10.1016/j.acra.2019.10.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。