PET/MRI 中的肺可视化:实施短回波时间与低翻转角容积内插屏气检查序列的协议

Lung visualisation on PET/MRI: implementing a protocol with a short echo-time and low flip-angle volumetric interpolated breath-hold examination sequence.
PubMed 文献 · Clin Radiol · 2019-12-01

研究纳入37例肿瘤患者,评估短回波时间、低翻转角VIBE(改良VIBE)序列在PET/MRI中检出肺部病变的诊断效能,并与标准VIBE、PET及CT比较。改良VIBE可重复性好,对≥6 mm肺结节的准确性优于标准VIBE和PET,与CT一致性很好,对<6 mm结节一致性欠满意。

要点

  • 改良VIBE序列对≥6 mm肺结节与CT一致性很好(患者分析α=0.88,病灶分析α=0.90),优于标准VIBE和PET。
  • 改良VIBE对<6 mm肺结节与CT一致性欠佳(患者分析α=0.54,病灶分析α=0.58),但仍高于标准VIBE和PET。
  • 改良VIBE观察者间一致性很高:结节<6 mm α=0.90、≥6 mm α=0.91、实变α=1.00、条带α=0.95(患者分析)。

核心结论

  • 改良VIBE可重复性好,评估≥6 mm肺结节时准确性优于标准VIBE和PET,与CT一致性很好;对更小结节一致性欠满意。

研究设计与样本

  • 研究为诊断性能评估,纳入37例接受CT和PET/MRI的肿瘤患者,PET/MRI包含改良VIBE(短TE、低FA)和标准VIBE的肺部序列。
  • 改良VIBE图像由三名评估者独立回顾性评估,另设三组分别评估标准VIBE、PET和CT图像,以CT为参考标准进行比较。

关键影像表现/征象

  • 改良VIBE用于检出肺结节、肺实质实变和条带,并与CT比较采用Krippendorff's alpha评估一致性。

诊断标准与关键数值

  • 患者分析(阳性定义为≥1个病灶):改良VIBE与CT比较,结节<6 mm α=0.54(标准VIBE α=0.41,PET α=0.09),结节≥6 mm α=0.88(标准VIBE α=0.74,PET α=0.42)。
  • 病灶分析(每个病灶存在/不存在):改良VIBE与CT比较,结节<6 mm α=0.58(标准VIBE α=0.44,PET α=0.09),结节≥6 mm α=0.90(标准VIBE α=0.79,PET α=0.50)。
  • 改良VIBE观察者间一致性:患者分析中结节<6 mm α=0.90、结节≥6 mm α=0.91、实变α=1.00、条带α=0.95;病灶分析中分别为α=0.89、α=0.93、α=1.00、α=0.95。

临床应用与阅片要点

  • 改良VIBE序列可用于PET/MRI协议中评估肺结节,对≥6 mm结节与CT一致性很好,阅片时对<6 mm结节需注意一致性较低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the diagnostic performance in detecting lung lesions of a short echo-time (TE) and low flip-angle (FA) volumetric interpolated breath-hold examination (VIBE) sequence included in the integrated positron-emission tomography (PET)/magnetic resonance imaging (MRI) protocol.

METHOD AND MATERIALS: Thirty-seven oncological patients who underwent computed tomography (CT) and PET/MRI, including both a dedicated short TE, low FA VIBE (modified VIBE) and a standard VIBE of the lung, were enrolled. Modified VIBE images were reviewed retrospectively and independently by three raters, to detect pulmonary nodules, parenchymal consolidation, and bands. Three other groups examined standard VIBE, PET, and CT images. MRI and PET findings were compared to CT using Krippendorff's alpha using patient-based and a lesion-based analysis. Krippendorff's alpha was calculated to assess the interobserver agreement among the three raters of the modified VIBE.

RESULTS: In the patient-based analysis (positivity ≥1 lesion), the comparison of modified VIBE with CT showed an alpha of 0.54 for nodules <6 mm (versus 0.41 for standard VIBE and 0.09 for PET) and an alpha of 0.88 for nodules ≥6 mm (versus 0.74 for standard VIBE and 0.42 for PET). On a lesion-based analysis (presence/absence of each lesion), modified VIBE compared to CT showed an alpha of0.58 for nodules <6 mm (versus 0.44 for standard VIBE and 0.09 for PET) and an alpha of 0.90 for nodules ≥6 mm (versus 0.79 for standard VIBE and 0.50 for PET). The alpha value for the interobserver agreement was 0.90 for nodules <6 mm, 0.91 for nodules ≥6 mm, 1.00 for consolidations, and 0.95 for bands in the patient-based analysis and 0.89, 0.93, 1.00, and 0.95 in the lesion-based analysis.

CONCLUSIONS: Modified VIBE proved to be reproducible, showed better accuracy than standard VIBE and PET, and very good concordance with CT in assessing lung nodules ≥6 mm, whereas the agreement was less satisfactory for smaller nodules.