非创伤性髋关节骨髓水肿:水-羟基磷灰石分解双能CT诊断准确性高
研究纳入40例非创伤性髋痛患者,在1个月内行快速kVp切换双能CT和MRI,回顾性评估80个髋关节水-羟基磷灰石图像上骨髓水肿的有无、范围和程度,并以MRI为参考标准。两位阅片者诊断敏感度均为85%,特异度分别为93%和73%,AUC分别为0.96和0.91;鉴别水肿存在的最佳水质量密度阈值分别为951 mg/cm3和957 mg/cm3。水肿越重,平均水密度值越高(p < 0.035)。
要点
- 水-羟基磷灰石双能CT诊断非创伤性髋关节骨髓水肿敏感度85%,特异度93%/73%,AUC 0.96/0.91。
- 鉴别骨髓水肿存在的最佳水质量密度阈值:阅片者1为951 mg/cm3(敏感度93%、特异度93%),阅片者2为957 mg/cm3(敏感度80%、特异度80%)。
- 骨髓水肿程度越重,平均水密度值越高(p < 0.035)。
关键影像表现/征象
- 水-羟基磷灰石图像上评估骨髓水肿的存在、范围(股骨头受累、头和颈、头至转子间)和程度(轻度、中度、重度水肿)。
- 通过基于感兴趣区的定量分析测定水-羟基磷灰石图像上的水质量密度(mg/cm3)。
诊断标准与关键数值
- 阅片者1诊断骨髓水肿的敏感度85%、特异度93%、准确率89%;阅片者2敏感度85%、特异度73%、准确率79%。
- 鉴别水肿存在与无水肿的AUC:阅片者1为0.96,阅片者2为0.91。
- 鉴别水肿存在的最佳水质量密度阈值:阅片者1为951 mg/cm3(敏感度93%、特异度93%),阅片者2为957 mg/cm3(敏感度80%、特异度80%)。
- 水肿越严重,平均水密度值越高(p < 0.035)。
临床应用与阅片要点
- 在非创伤性髋痛患者中,水-羟基磷灰石双能CT可评估骨髓水肿的存在、范围和程度,可能作为部分患者MRI的替代方法。
- 定量水质量密度有助于鉴别骨髓水肿,阈值951 mg/cm3对应敏感度93%、特异度93%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic performance of dual-energy CT with water-hydroxyapatite (HAP) imaging for bone marrow edema in patients with non-traumatic hip pain.
METHODS: Forty patients (mean age, 58 years; 16 male and 24 female) who underwent rapid kVp-switching dual-energy CT and MRI within 1 month between April 2018 and February 2019 with hip pain but no trauma were enrolled. Two radiologists retrospectively evaluated 80 hip joints for the presence, extent (femoral head involved, head and neck, and head to intertrochanter), and severity (mild edema, moderate, severe) of bone marrow edema on dual-energy water-HAP images. Water mass density (mg/cm3) on water-HAP images was determined with region of interest-based quantitative analysis. MRI served as the standard of reference.
RESULTS: Sensitivity, specificity, and accuracy of readers 1 and 2 for the identification of bone marrow edema in water-HAP images were 85% and 85%, 93% and 73%, and 89% and 79%, respectively. The area under the receiver operating characteristic curve was 0.96 for reader 1 and 0.91 for reader 2 for differentiation of the presence of edema from no edema. The optimal water mass density to classify the presence of edema for reader 1 was 951 mg/cm3 with 93% sensitivity and 93% specificity and for reader 2 was 957 mg/cm3 with 80% sensitivity and 80% specificity. The more severe the edema, the higher was the mean water density value (p < 0.035).
CONCLUSION: Dual-energy water-HAP images showed good diagnostic performance for bone marrow edema in patients with non-traumatic hip pain.
KEY POINTS: • Dual-energy water-HAP imaging depicts bone marrow edema in patients with non-traumatic hip pain and may serve as an alternative to MRI in select patients. • A cutoff value of 951 mg/cm3mean water mass density results in 93% sensitivity and 93% specificity for the detection of bone marrow edema. • The more severe the bone marrow edema, the higher the mean water density value.
引用
- Son W, Park C, Jeong HS, et al. Bone marrow edema in non-traumatic hip: high accuracy of dual-energy CT with water-hydroxyapatite decomposition imaging. Eur Radiol. 2019. PMID: 31822976. doi:10.1007/s00330-019-06519-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。