3T三维脂肪饱和对比增强血管壁磁共振成像提高巨细胞动脉炎的诊断准确性
这项前瞻性两中心研究纳入79例参与者,比较3D与2D对比增强血管壁MRI诊断巨细胞动脉炎的准确性。重新格式化的3D序列对颅外动脉炎性改变的敏感度高于2D(80% vs 70%)且特异度更高(100% vs 85%);3D对颅内动脉炎性改变的敏感度也更高(20% vs 8%)。结论为3D对比增强血管壁MRI支持更准确的巨细胞动脉炎诊断。
要点
- 重新格式化的3D对比增强血管壁MRI对颅外动脉炎性改变的敏感度为80%(41/51),高于2D的70%(35/50)。
- 重新格式化的3D对比增强血管壁MRI特异度为100%(27/27),高于2D的85%(22/26)。
- 3D对比增强血管壁MRI检测颅内动脉炎性改变的敏感度为20%(10/51),高于2D的8%(4/50)。
诊断标准与关键数值
- 重新格式化的3D对比增强血管壁MRI显示颅外动脉炎性改变的敏感度为41/51(80%),高于轴位-only 3D的37/51(73%)(p=0.046),也高于2D的35/50(70%)(p=0.03)。
- 重新格式化的3D对比增强血管壁MRI显示颅外动脉炎性改变的特异度为27/27(100%),高于2D的22/26(85%)(p=0.04)。
- 3D对比增强血管壁MRI检测颅内动脉炎性改变的敏感度为10/51(20%),高于2D的4/50(8%)(p=0.01)。
- 2D与3D对比增强血管壁MRI的观察者间一致性均极好,κ分别为0.84和0.82。
临床应用与阅片要点
- 3D对比增强血管壁MRI是用于诊断巨细胞动脉炎的高准确度、无创诊断工具。
- 3D对比增强血管壁成像在较短时间内即可完成,允许立即评估颅外和颅内动脉。
- 当怀疑巨细胞动脉炎有颅内表现时,3D对比增强血管壁MRI可能被考虑作为诊断工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the diagnostic accuracy of 3D versus 2D contrast-enhanced vessel-wall (CE-VW) MRI of extracranial and intracranial arteries in the diagnosis of GCA.
METHODS: This prospective two-center study was approved by a national research ethics board and enrolled participants from December 2014 to October 2017. A protocol including both a 2D and a 3D CE-VW MRI at 3 T was performed in all patients. Two neuroradiologists, blinded to clinical data, individually analyzed separately and in random order 2D and 3D sequences in the axial plane only or with reformatting. The primary judgment criterion was the presence of GCA-related inflammatory changes of extracranial arteries. Secondary judgment criteria included inflammatory changes of intracranial arteries and the presence of artifacts. A McNemar's test was used to compare 2D to 3D CE-VW MRIs.
RESULTS: Seventy-nine participants were included in the study (42 men and 37 women, mean age 75 (± 9.5 years)). Fifty-one had a final diagnosis of GCA. Reformatted 3D CE-VW was significantly more sensitive than axial-only 3D CE-VW or 2D CE-VW when showing inflammatory change of extracranial arteries: 41/51(80%) versus 37/51 (73%) (p = 0.046) and 35/50 (70%) (p = 0.03). Reformatted 3D CE-VW was significantly more specific than 2D CE-VW: 27/27 (100%) versus 22/26 (85%) (p = 0.04). 3D CE-VW showed higher sensitivity than 2D CE-VW when detecting inflammatory changes of intracranial arteries: 10/51(20%) versus 4/50(8%), p = 0.01. Interobserver agreement was excellent for both 2D and 3D CE-VW MRI: κ = 0.84 and 0.82 respectively.
CONCLUSIONS: 3D CE-VW MRI supported more accurate diagnoses of GCA than 2D CE-VW.
KEY POINTS: • 3D contrast-enhanced vessel-wall magnetic resonance imaging is a high accuracy, non-invasive diagnostic tool used to diagnose giant cell arteritis. • 3D contrast-enhanced vessel-wall imaging is feasible for clinicians to complete within a relatively short time, allowing immediate assessment of extra and intracranial arteries. • 3D contrast-enhanced vessel-wall magnetic resonance imaging might be considered a diagnostic tool when intracranial manifestation of GCA is suspected.
引用
- Poillon G, Collin A, Benhamou Y, et al. Increased diagnostic accuracy of giant cell arteritis using three-dimensional fat-saturated contrast-enhanced vessel-wall magnetic resonance imaging at 3 T. Eur Radiol. 2019. PMID: 31811430. doi:10.1007/s00330-019-06536-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。