文献速递神经头颈CT

双能CT确定放射外科脑转移瘤靶区勾画的最佳虚拟单色能量水平

Determination of optimal virtual monochromatic energy level for target delineation of brain metastases in radiosurgery using dual-energy CT.
PubMed 文献 · Br J Radiol · 2019-12-20

20例患者共42个脑转移瘤行对比增强双能CT,在40–140 keV范围以1 keV步进分析虚拟单色图像,以脑实质与转移瘤间对比噪声比最高确定为最佳能量水平(63 keV)。与120 kVp等效的参考虚拟单色图像(77 keV)相比,63 keV的病灶对比度和对比噪声比及主观整体图像质量、肿瘤勾画评分均显著更高。

要点

  • 对比增强双能CT中,63 keV虚拟单色图像在脑实质与转移瘤间对比噪声比最高。
  • 63 keV较77 keV参考虚拟单色图像提高病灶对比度(37.4 HU vs 24.7 HU)和对比噪声比(1.1 vs 0.8)。
  • 63 keV在整体图像质量和肿瘤勾画主观评分上均优于77 keV参考图像。

关键影像表现/征象

  • 最佳虚拟单色图像为63 keV,其病灶对比度和对比噪声比显著高于77 keV参考图像(病灶对比度37.4 HU vs 24.7 HU;对比噪声比1.1 vs 0.8,p < 0.01)。
  • 三位放射肿瘤科医生主观评估显示,63 keV在整体图像质量(3.2 vs 2.9)和肿瘤勾画(3.5 vs 2.9)上均显著优于77 keV参考图像(p < 0.01)。

诊断标准与关键数值

  • 以脑实质与转移瘤间对比噪声比最高确定最佳虚拟单色图像能量水平为63 keV。
  • 参考虚拟单色图像定义为120 kVp等效,即77 keV。
  • 主观评估采用五点量表,由三位放射肿瘤科医生对整体图像质量和肿瘤勾画进行评分。

临床应用与阅片要点

  • 在放射外科脑转移瘤对比增强双能CT靶区勾画中,63 keV虚拟单色图像可提高肿瘤可见性和勾画准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Determination of the optimal energy level of virtual monochromatic image (VMI) for brain metastases in contrast-enhanced dual-energy CT (DECT) for radiosurgery and assessment of the subjective and objective image quality of VMI at the optimal energy level.

METHODS: 20 patients (total of 42 metastases) underwent contrast-enhanced DECT. Spectral image analysis of VMIs at energy levels ranging from 40 to 140 keV in 1 keV increments was performed to determine the optimal VMI (VMIopt) as the one corresponding to the highest contrast-to-noise ratio (CNR) between brain parenchyma and the metastases. The objective and subjective values of VMIopt were compared to those of the VMI with 120 kVp equivalent, defined as reference VMI (VMIref, 77 keV). The objective measurement parameters included mean HU value and SD of tumor and brain parenchyma, absolute lesion contrast (LC), and CNR. The subjective measurements included five-point scale assessment of "overall image quality" and "tumor delineation" by three radiation oncologists.

RESULTS: The VMI at 63 keV was defined as VMIopt. The LC and CNR of VMIopt were significantly (p < 0.01) higher than those of VMIref (LC: 37.4 HU vs 24.7 HU; CNR: 1.1 vs 0.8, respectively). Subjective analysis rated VMIopt significantly (p < 0.01) superior to VMIref with respect to the overall image quality (3.2 vs 2.9, respectively) and tumor delineation (3.5 vs 2.9, respectively).

CONCLUSION: The VMI at 63 keV derived from contrast-enhanced DECT yielded the highest CNR and improved the objective and subjective image quality for radiosurgery, compared to VMIref.

ADVANCES IN KNOWLEDGE: This paper investigated for the first time the optimal energy level of VMI in DECT for brain metastases. The findings will lead to improvement in tumor visibility with optimal VMI and consequently supplement accuracy delineation of brain metastases.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Karino T, Ohira S, Kanayama N, et al. Determination of optimal virtual monochromatic energy level for target delineation of brain metastases in radiosurgery using dual-energy CT. Br J Radiol. 2019. PMID: 31825643. doi:10.1259/bjr.20180850

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。