文献速递神经MR

弥散峰度成像在原发性中枢神经系统淋巴瘤与高级别胶质瘤间存在差异,且与不同的核质比相关:一项基于组织病理学与活检的研究

Diffusion kurtosis imaging differs between primary central nervous system lymphoma and high-grade glioma and is correlated with the diverse nuclear-to-cytoplasmic ratio: a histopathologic, biopsy-based study.
PubMed 文献 · Eur Radiol · 2019-12-19

研究回顾性纳入2013年5月至2016年11月经病理证实的44例高级别胶质瘤和43例原发性中枢神经系统淋巴瘤标本,比较DKI弥散与峰度参数同细胞密度及核质比的相关性。淋巴瘤的MK、K//、K⊥均高于高级别胶质瘤(均p<0.001),而FA、MD、λ//、λ⊥无显著差异;淋巴瘤核质比显著高于高级别胶质瘤(p<0.001),且各DKI参数与淋巴瘤核质比显著相关。结论认为峰度参数差异与两者核质比不同相关。

要点

  • 淋巴瘤MK、K//、K⊥均高于高级别胶质瘤(均p<0.001),而FA、MD、λ//、λ⊥无显著差异。
  • 淋巴瘤核质比显著高于高级别胶质瘤(p<0.001),细胞密度两组差异未达统计学显著(p=0.125)。
  • 淋巴瘤中FA、MD、λ//、λ⊥、MK、K//、K⊥均与核质比显著相关,细胞密度与任何峰度或弥散参数均不相关。

核心结论

  • 原发性中枢神经系统淋巴瘤与高级别胶质瘤之间峰度参数的差异与两者不同的核质比相关。

研究设计与样本

  • 回顾性研究,纳入2013年5月至2016年11月经病理证实的44例高级别胶质瘤和43例原发性中枢神经系统淋巴瘤标本,采用DKI衍生弥散与峰度参数,并与组织病理学细胞密度及核质比对照。

关键影像表现/征象

  • 原发性中枢神经系统淋巴瘤MK为0.857(0.693-0.924)、K//为0.837(0.660-0.941)、K⊥为0.834(0.685-0.937)。
  • 高级别胶质瘤MK为0.629(0.524-0.716)、K//为0.575(0.511-0.689)、K⊥为0.675(0.532-0.766),三项均低于淋巴瘤(均p<0.001)。
  • FA、MD、λ//、λ⊥在高级别胶质瘤与原发性中枢神经系统淋巴瘤之间无显著差异。

诊断标准与关键数值

  • 淋巴瘤MK、K//、K⊥均高于高级别胶质瘤,差异均p<0.001(Mann-Whitney U检验,显著性水平p<0.007[0.05/7],Bonferroni校正)。
  • 细胞密度淋巴瘤高于高级别胶质瘤,p=0.125,未达统计学显著。
  • 核质比淋巴瘤显著高于高级别胶质瘤,p<0.001。
  • 淋巴瘤中FA、MD、λ//、λ⊥、MK、K//、K⊥与核质比的相关系数分别为rho=0.418、-0.722、-0.525、-0.768、0.704、0.579、0.686。
  • 淋巴瘤与高级别胶质瘤的细胞密度均与任何峰度或弥散参数不相关。

临床应用与阅片要点

  • DKI对鉴别原发性中枢神经系统淋巴瘤与高级别胶质瘤有相当价值。
  • DKI可提供关于核质比的重要信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine whether water kurtosis and diffusional metrics derived from diffusional kurtosis imaging (DKI) within primary central nervous system lymphomas (PCNSLs) and high-grade gliomas (HGGs) correlate with cellularity and/or nuclear-to-cytoplasmic (N/C) ratio.

METHODS: Forty-four and 43 pathologically confirmed high-grade glioma and primary central nervous system lymphoma specimens between May 2013 and November 2016 were retrospectively reviewed. Diffusional metrics, kurtosis metrics, cellularity, and N/C ratios in PCNSLs and HGGs were compared using the Mann-Whitney U test (significant level, p < 0.007 [0.05/7]); Bonferroni correction).

RESULTS: Mean kurtosis (MK), axial kurtosis (K//), and radial kurtosis (K⊥) in PCNSLs were 0.857 (0.693-0.924), 0.837 (0.660-0.941), and 0.834 (0.685-0.937), respectively; and 0.629 (0.524-0.716), 0.575 (0.511-0.689), and 0.675 (0.532-0.766), respectively, in HGGs (all p < 0.001). No significant differences in fractional anisotropy (FA), mean diffusion (MD), axial diffusion (λ//), and radial diffusion (λ⊥) were found between HGGs and PCNSLs. Cellularity was higher in PCNSLs than in HGGs (p = 0.125); whereas, the N/C ratio in PCNSLs was significantly higher than that in HGGs (p < 0.001). All DKI metrics (FA, MD, λ//, λ⊥, MK, K//, and K⊥) were significantly correlated with N/C ratio in PCNSLs with correlation coefficients being rho = 0.418, - 0.722, - 0.525, - 0.768, 0.704, 0.579, and 0.686, respectively. Cellularity in PCNSLs and HGGs did not correlate with any kurtosis or diffusional metrics.

CONCLUSIONS: Difference of kurtosis parameters between PCNSLs and HGGs is correlated with their diverse N/C ratio.

KEY POINTS: • DKI has considerable value in differentiating between PCNSLs and HGGs. • DKI can provide important information on nuclear-to-cytoplasmic ratio. • Difference of kurtosis parameters between PCNSLs and HGGs correlated well with their diverse N/C ratios.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Haopeng P, Xuefei D, Yan R, et al. Diffusion kurtosis imaging differs between primary central nervous system lymphoma and high-grade glioma and is correlated with the diverse nuclear-to-cytoplasmic ratio: a histopathologic, biopsy-based study. Eur Radiol. 2019. PMID: 31858206. doi:10.1007/s00330-019-06544-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。