快速T2与FLAIR序列在儿童脑MRI中的诊断等效性:一项先导研究
该前瞻性先导研究纳入77名儿童,在3T下比较常规多平面图像与采集时间缩短约50%的快速轴位T2和FLAIR序列,由两名盲法儿童神经放射科医生评估12项发现。快速序列与常规序列观察者内一致性89.2%–92.3%,观察者间一致性86.1%–88.4%;常规FLAIR对白质内小(<5 mm)T2灶的观察者间一致性显著高于快速FLAIR,其余序列间无差异。清醒受试者中快速序列伪影显著更少(P<0.05)。结论认为常规T2和FLAIR序列可优化缩短采集时间而保持诊断等效性,且快速序列对运动伪影更不敏感。
要点
- 快速T2和FLAIR序列采集时间缩短约50%,整体诊断等效性与常规序列相当。
- 常规FLAIR对白质内小(<5 mm)T2灶的观察者间一致性显著高于快速FLAIR。
- 清醒儿童中快速序列运动伪影显著少于常规序列(P<0.05)。
核心结论
- 常规T2和FLAIR序列可优化以缩短采集时间,同时保持诊断等效性。
- 快速序列对运动伪影更不敏感。
研究设计与样本
- 机构审查委员会批准的前瞻性先导研究,纳入77名儿童(平均年龄11.3岁)。
- 受试者在3特斯拉下接受常规多平面脑MRI,随后接受采集时间优化缩短约50%的快速轴位T2和FLAIR序列。
- 由两名盲法儿童神经放射科医生独立阅片,评估12项发现;第三名独立阅片者对观察者内不一致进行裁定。
关键影像表现/征象
- 快速序列与常规序列观察者内一致性范围为89.2%至92.3%。
- 观察者间一致性范围为86.1%至88.4%。
- 常规FLAIR对白质内小(<5 mm)T2灶的观察者间一致性显著高于快速FLAIR,其余序列间观察者间一致性无差异。
- 清醒受试者中快速序列伪影显著更少(P<0.05)。
诊断标准与关键数值
- 诊断等效性通过观察者内和观察者间一致性评估,观察者内一致性89.2%–92.3%,观察者间一致性86.1%–88.4%。
- 运动伪影采用先前验证的评分进行评分。
临床应用与阅片要点
- 快速T2和FLAIR序列可作为常规序列的替代以缩短采集时间并减少运动伪影。
- 阅片时需注意快速FLAIR对白质内小(<5 mm)T2灶的观察者间一致性低于常规FLAIR。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Faster and motion robust magnetic resonance imaging (MRI) sequences are desirable in pediatric brain MRI as they can help reduce the need for monitored anesthesia care, which is a costly and limited resource that carries medical risks.
OBJECTIVE: To evaluate the diagnostic equivalency of commercially available accelerated motion robust MR sequences relative to standard sequences.
MATERIALS AND METHODS: This was an institutional review board-approved prospective study. Subjects underwent a clinical brain MRI using conventional multiplanar images at 3 Tesla followed by fast axial T2 and FLAIR (fluid-attenuated inversion recovery) sequences optimized for an approximately 50% reduction in acquisition time. Conventional and fast images from each subject were reviewed by two blinded pediatric neuroradiologists. The readers evaluated the presence of 12 findings. Intra-observer agreement was estimated for fast versus conventional sequences. For each set of sequences, interobserver agreement calculations and chi-square tests were used to evaluate differences between fast and conventional acquisitions. An independent third reader reviewed the intra-observer discrepancies and adjudicated them as being more conspicuous on fast sequence, conventional sequence or the equivalent. The readers also were asked to rate motion artifacts with a previously validated score.
RESULTS: Images from 77 children (mean age: 11.3 years) were analyzed. Intra-observer agreement (fast versus conventional) ranged between 89.2% and 92.3%. Interobserver agreement ranged between 86.1% and 88.4%. Interobserver agreement was significantly higher for conventional FLAIR relative to fast FLAIR for small (<5 mm) foci of T2 in the white matter. Otherwise, interobserver agreement was not different between the fast and conventional sequences. For awake subjects, fast sequences had significantly fewer artifacts (P<0.05).
CONCLUSION: Conventional T2 and FLAIR sequences can be optimized to shorten acquisition while maintaining diagnostic equivalency. These faster sequences were also less susceptible to motion artifacts.
引用
- Jaimes C, Yang E, Connaughton P, et al. Diagnostic equivalency of fast T2 and FLAIR sequences for pediatric brain MRI: a pilot study. Pediatr Radiol. 2019. PMID: 31863192. doi:10.1007/s00247-019-04584-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。