扩散张量成像影像组学在低级别胶质瘤中的应用:改善异柠檬酸脱氢酶突变状态的分型
回顾性纳入168例经病理确诊的低级别胶质瘤患者,从DTI提取158个影像组学特征、从常规MRI提取253个影像组学特征,用随机森林模型预测IDH突变状态。在常规影像组学基础上加入DTI影像组学显著提高IDH分型准确度(AUC 0.900 vs 0.835,p=0.006),而加入DTI直方图参数仅呈非显著改善趋势(AUC 0.869,p=0.150)。
要点
- 常规MRI影像组学模型预测IDH状态的AUC为0.835(95%CI 0.773-0.896)。
- 常规影像组学联合DTI影像组学模型AUC为0.900(95%CI 0.855-0.945),显著优于常规影像组学模型(p=0.006)。
- 常规影像组学联合DTI直方图参数模型AUC为0.869(95%CI 0.816-0.922),较常规影像组学模型的改善未达统计学显著(p=0.150)。
诊断标准与关键数值
- 常规影像组学模型预测IDH状态的AUC为0.835(95%CI 0.773-0.896)。
- 常规影像组学联合DTI影像组学模型预测IDH状态的AUC为0.900(95%CI 0.855-0.945),较常规影像组学模型的改善显著(p=0.006)。
- 常规影像组学联合DTI直方图参数模型预测IDH状态的AUC为0.869(95%CI 0.816-0.922),较常规影像组学模型的改善未达统计学显著(p=0.150)。
- 常规影像组学联合DTI影像组学模型与常规影像组学联合DTI直方图参数模型比较,AUC 0.900 vs 0.869,差异显著(p=0.040)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate whether diffusion tensor imaging (DTI) radiomics with machine learning improves the prediction of isocitrate dehydrogenase (IDH) mutation status of lower-grade gliomas beyond radiomic features from conventional MRI and DTI histogram parameters.
METHODS: A total of 168 patients with pathologically confirmed lower-grade gliomas were retrospectively enrolled. A total of 158 and 253 radiomic features were extracted from DTI (DTI radiomics) and conventional MRI (T1-weighted image with contrast enhancement, T2-weighted image, and FLAIR [conventional radiomics]), respectively. The random forest models for predicting IDH status were trained with variable combinations as follows: (1) DTI radiomics, (2) conventional radiomics, (3) conventional radiomics + DTI radiomics, and (4) conventional radiomics + DTI histogram. The models were validated with nested cross-validation. The predictive performances of those models were compared by using area under the curve (AUC) from receiver operating characteristic analysis, and 95% confidence interval (CI) was calculated.
RESULTS: Adding DTI radiomics to conventional radiomics significantly improved the accuracy of IDH status subtyping (AUC, 0.900 [95% CI, 0.855-0.945], p = 0.006), whereas adding DTI histogram parameters yielded nonsignificant trend toward improvement (0.869 [95% CI, 0.816-0.922], p = 0.150) compared with the model with conventional radiomics alone (0.835 [95% CI, 0.773-0.896]). The performance of the model consisting of both DTI and conventional radiomics was significantly superior than that of model consisting of both DTI histogram parameters and conventional radiomics (0.900 vs 0.869, p = 0.040).
CONCLUSION: DTI radiomics with machine learning can help improve the subtyping of IDH status beyond conventional radiomics and DTI histogram parameters in patients with lower-grade gliomas.
引用
- Park CJ, Choi YS, Park YW, et al. Diffusion tensor imaging radiomics in lower-grade glioma: improving subtyping of isocitrate dehydrogenase mutation status. Neuroradiology. 2019. PMID: 31820065. doi:10.1007/s00234-019-02312-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。