文献速递神经技术与安全USMR

牛脑声速与衰减系数温度依赖性的离体研究

Speed of Sound and Attenuation Temperature Dependence of Bovine Brain: Ex Vivo Study.
PubMed 文献 · J Ultrasound Med · 2019-12-23

本研究对16个离体牛脑样本(7个白质、9个皮质)在逐步加热至约45°C后冷却过程中,用计算机化超声系统经透射模式重复扫描,同步以热电偶测温,计算归一化声速与衰减系数随温度的变化。结果显示归一化衰减系数与声速曲线呈现与温度相关的特征性冷却时间行为,声速曲线可清晰区分组织类型但白质轨迹更分散,白质衰减系数随温度呈线性行为,两种组织温度模式较相似。作者认为这些发现可能有助于开发聚焦超声手术中的超声温度监测方法。

要点

  • 离体牛脑白质与皮质在冷却过程中的归一化声速曲线可清晰区分组织类型,但白质轨迹更分散。
  • 白质衰减系数随温度呈线性行为,而两种组织的温度模式较为相似。
  • 归一化声速与衰减系数曲线均呈现与温度相关的特征性冷却时间行为。

关键影像表现/征象

  • 归一化衰减系数与声速曲线呈现与温度相关的特征性冷却时间行为。
  • 声速曲线可清晰区分白质与皮质,但白质轨迹更分散。
  • 白质衰减系数随温度呈线性行为,两种组织的温度模式较为相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Brain treatments using focused ultrasound (FUS) offer a new range of noninvasive transcranial therapies. The acoustic energy deposition during these procedures may induce a temperature elevation in the tissue; therefore, noninvasive thermal monitoring is essential. Magnetic resonance imaging is the current adopted monitoring modality, but its high operational costs and limited availability may hinder the accessibility to FUS treatments. Aiming at the development of a thermometric ultrasound (US) method for the brain, the specific objective of this investigation was to study the acoustic thermal response of the speed of sound (SOS) and attenuation coefficient (AC) of different brain tissues: namely white matter (WM) and cortical matter.

METHODS: Sixteen ex vivo bovine brain samples were investigated. These included 7 WM and 9 cortical matter samples. The samples were gradually heated to about 45°C and then repeatedly scanned while cooling using a computerized US system in the through-transmission mode. The temperature was simultaneously registered with thermocouples. From the scans, the normalized SOS and AC for both tissues were calculated.

RESULTS: The results demonstrated a characteristic cooldown temporal behavior for the normalized AC and SOS curves, which were related to the temperature. The SOS curves enabled clear differentiation between the tissue types but depicted more scattered trajectories for the WM tissue. As for the AC curves, the WM depicted a linear behavior in relation to the temperature. However, both tissue types had rather similar temperature patterns.

CONCLUSIONS: These findings may contribute to the development of a US temperature-monitoring method during FUS procedures.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Dahis D, Azhari H. Speed of Sound and Attenuation Temperature Dependence of Bovine Brain: Ex Vivo Study. J Ultrasound Med. 2019. PMID: 31868251. doi:10.1002/jum.15203

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。