文献速递神经MR

与癫痫发作相关的皮层下T2 FLAIR信号减低

Decreased Subcortical T2 FLAIR Signal Associated with Seizures.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-12-05

研究回顾性分析了29例脑影像上出现T2/T2 FLAIR信号异常减低的患者,其中75.9%在影像当天有临床癫痫发作记录,96.6%在DWI上有对应低信号,ADC均正常,89.7%在SWI/梯度回波上有对应低信号,最常见的伴发病理为硬膜下血肿;24小时内脑电图均可异常且与信号异常区域对应。

要点

  • T2/T2 FLAIR皮层下白质信号减低需考虑癫痫发作相关改变,常伴DWI和SWI低信号而ADC正常。
  • 病变多位于前循环供血区,75.9%为单侧,常见伴发病理为硬膜下血肿。
  • 影像当天有临床癫痫发作记录者占75.9%,24小时内脑电图异常且与信号异常区域对应。

关键影像表现/征象

  • 异常信号在75.9%的患者中为单侧,累及大脑各叶但仅见于前循环供血区。
  • 96.6%的患者在DWI上有对应低信号,所有病例ADC均正常。
  • 89.7%的患者在SWI/梯度回波上有对应低信号;44.8%的患者接受增强扫描,均无异常强化。
  • 最常见的伴发病理为硬膜下血肿。

诊断标准与关键数值

  • T2/T2 FLAIR白质信号减低为异常表现,常伴DWI对应低信号而ADC正常,SWI/梯度回波常见对应低信号。
  • 75.9%的患者在影像当天有临床癫痫发作记录;65.5%的患者有影像后24小时内的脑电图,这些脑电图均异常,且改变局限于异常MR信号区域(单侧信号时)或为双侧(MR改变为双侧时)。

临床应用与阅片要点

  • 阅片遇到T2/T2 FLAIR皮层下白质信号减低时,应结合DWI、ADC和SWI信号特点,并询问影像当天有无临床癫痫发作。
  • 注意病变仅见于前循环供血区,单侧多见,需排查硬膜下血肿等伴发病理。
  • 增强扫描常无异常强化,可结合24小时内脑电图定位异常信号区域。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Abnormally decreased T2/T2 FLAIR signal can be seen on brain imaging of patients who are experiencing clinical or subclinical seizures and can be associated with various intracranial pathologies. We identified 29 such patients. The abnormal signal was unilateral in 75.9% of patients. It affected various lobes of the brain, but only in the anterior circulation. In 28 patients (96.6%), there was corresponding decreased signal on DWI. The ADC was normal in all cases. In 26 patients (89.7%), there was corresponding low signal on SWI/gradient recalled-echo; 44.8% of patients underwent contrast-enhanced scans, and there was no abnormal enhancement. Twenty-two (75.9%) patients had documented clinical seizures on the day of imaging. The most frequent concomitant pathology was a subdural hematoma. Electroencephalograms obtained within 24 hours of imaging were available in 65.5%. Findings of all of these electroencephalograms were abnormal, and these electroencephalogram changes were either localized to the area of the abnormal MR imaging signal (where the signal was unilateral) or were bilateral (where the MR imaging changes were bilateral). In summary, decreased white matter T2/T2 FLAIR signal changes can be seen in patients with remarkably similar clinical findings (particularly seizures). These changes are often correlated with abnormal electroencephalogram activity localized to the involved lobes.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Nicholson P, Abdulla S, Alshafai L, et al. Decreased Subcortical T2 FLAIR Signal Associated with Seizures. AJNR Am J Neuroradiol. 2019. PMID: 31806597. doi:10.3174/ajnr.A6328

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。