全身介入操作:哪种方法是CT引导的最佳选择?
该研究基于前瞻性随机对照多中心CTNAV2研究的回顾性分析,纳入385例患者,比较序贯CT透视引导与螺旋引导在全身介入操作中的安全性、有效性、速度和辐射剂量。结果显示两组在成功率、操作时间和主要并发症方面无显著差异,但序贯组患者辐射剂量降低84%。
要点
- 序贯CT透视引导与螺旋引导在成功率和主要并发症方面无显著差异。
- 序贯组患者辐射剂量较螺旋组降低84%(54.8 vs 352.6 mGy cm)。
- 两组操作时间无显著差异(7分40秒 vs 7分13秒,p=0.507)。
诊断标准与关键数值
- 成功率:序贯组99.6% vs 螺旋组99.3%(p=0.680),无显著差异。
- 主要并发症:序贯组2.43% vs 螺旋组5.8%(p=0.101),无显著差异。
- 操作时间:序贯组7分40秒±5分48秒 vs 螺旋组7分13秒±7分33秒(p=0.507),无显著差异。
- 患者辐射剂量:序贯组54.8±51.8 mGy cm vs 螺旋组352.6±404 mGy cm(p<0.0001),序贯组降低84%。
临床应用与阅片要点
- 序贯CT透视引导在保持安全性和有效性的同时可显著降低患者辐射剂量,作者结论认为其似乎与螺旋引导同样安全、有效且快速。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare sequential fluoroscopy guidance with spiral guidance in terms of safety, effectiveness, speed and radiation in interventional whole body procedures.
METHODS: This study was a retrospective analysis of data from the prospective, randomised controlled, multicentre CTNAV2 study. The present analysis included 385 patients: 247 in the sequential group (SEQ) and 138 in the spiral group (SPI). Safety was assessed by the number of major complications. Effectiveness was measured according to the number of targets reached. Data on procedural time and radiation delivered to patients were also collected.
RESULTS: There was no significant difference between the two groups (SEQ vs SPI) regarding the success rate (99.6% vs 99.3%, p = 0.680), procedural time (7 min 40 s ± 5 min 48 s vs 7 min 13 s ± 7 min 33 s, p = 0.507), or major complications (2.43% vs 5.8%, p = 0.101). Radiation dose to patients was 84% lower in the sequential group (54.8 ± 51.8 mGy cm vs 352.6 ± 404 mGy cm, p < 0.0001).
CONCLUSIONS: Sequential CT fluoroscopy-guided whole-body interventional procedures seems to be as safe, effective and fast as spiral guidance, while also yielding a significant decrease in the radiation dose to patients.
KEY POINTS: • Sequential CT fluoroscopy and spiral acquisition are comparable in terms of safety, effectiveness and speed. • Procedural times are comparable despite an increased number of acquisitions in sequential fluoroscopy. • Radiation dose to patients is 84% lower in sequential fluoroscopy compared with spiral CT.
引用
- Lustig JP, Aubry S, Vidal C, et al. Body interventional procedures: which is the best method for CT guidance? Eur Radiol. 2019. PMID: 31776742. doi:10.1007/s00330-019-06490-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。