文献速递腹部外周血管介入USDSA

高机械指数对比增强超声:经颈静脉肝内门体分流术后随访的新方法

Contrast-enhanced ultrasound at high mechanical index: a new method for transjugular intrahepatic portosystemic shunt follow-up.
PubMed 文献 · Clin Radiol · 2019-11-22

本研究纳入50例疑似分流功能障碍患者,比较彩色多普勒血流成像、低机械指数对比增强超声与高机械指数对比增强超声识别分流异常的能力,以门静脉造影为参考标准。高机械指数对比增强超声诊断分流异常的敏感度94.4%、特异度93.8%、AUC 94%,其诊断准确率(80%)高于彩色多普勒血流成像(50%)和低机械指数对比增强超声(70%),作者认为其可作为临床检测TIPS异常的一种替代互补新方法。

要点

  • 高机械指数对比增强超声诊断TIPS分流异常的敏感度94.4%、特异度93.8%、AUC 94%。
  • 彩色多普勒血流成像诊断分流异常的准确率为50%,低于低机械指数对比增强超声的70%和高机械指数对比增强超声的80%。
  • 高机械指数与低机械指数对比增强超声之间的诊断差异无统计学意义。

核心结论

  • 高机械指数对比增强超声相比彩色多普勒血流成像和低机械指数对比增强超声具有较高的敏感度和特异度,为临床检测TIPS异常提供了一种替代互补的新方法。

研究设计与样本

  • 本研究纳入50例疑似分流功能障碍患者,分为彩色多普勒血流成像组、低机械指数对比增强超声组和高机械指数对比增强超声组。
  • 以门静脉造影作为识别分流异常的参考标准,计算敏感度、特异度、AUC、阳性预测值和阴性预测值。

关键影像表现/征象

  • 50例疑似分流功能障碍患者中,18例(36%)门静脉造影发现异常,其中8例为分流道闭塞、10例为支架狭窄。

诊断标准与关键数值

  • 高机械指数对比增强超声诊断分流异常的敏感度为94.4%、特异度为93.8%、AUC为94%。
  • 彩色多普勒血流成像、低机械指数对比增强超声和高机械指数对比增强超声的诊断准确率分别为50%、70%和80%。
  • 彩色多普勒血流成像在识别分流异常方面的敏感度和准确率低于低机械指数或高机械指数对比增强超声。
  • 高机械指数对比增强超声的诊断结果相比低机械指数对比增强超声提供相对较高的敏感度/准确率并与门静脉造影相关性更好,但低机械指数与高机械指数对比增强超声之间的差异无统计学意义。

临床应用与阅片要点

  • 作者认为高机械指数对比增强超声可作为临床检测TIPS异常的一种替代互补新方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the diagnostic value of contrast-enhanced ultrasound (CEUS) at high mechanical index (MI) for transjugular intrahepatic portosystemic shunt (TIPS) follow-up.

MATERIALS AND METHODS: Fifty patients with a suspected diagnosis of shunt dysfunction were enrolled in the present study. The patients were divided into three groups: colour Doppler flow imaging (CDFI), CEUS at low MI and CEUS at high MI. The portography was used as the reference standard regarding the ability to identify shunt abnormalities. The sensitivity, specificity, area under the curve (AUC), positive predictive value, and negative predictive value were calculated.

RESULTS: Out of 50 patients with a suspected diagnosis of shunt dysfunction, 18 (36%) patients had abnormal portogram findings, among which there were eight shunt occlusions and 10 stent stenosis. The sensitivity, specificity, and AUC for shunt abnormalities of CEUS at high MI are 94.4%, 93.8%, and 94%, respectively. CDFI was less sensitive and accurate than CEUS at low or high MI regarding shunt abnormality identification. Although the diagnostic results of CEUS at high MI offered relatively higher sensitivity/accuracy and correlated better with portography than that of CEUS at low MI, the difference between CEUS at low MI and high MI was not significant. The diagnostic accuracy of CDFI, CEUS at low MI, and CEUS at high MI are 50%, 70%, and 80% respectively.

CONCLUSIONS: With the relatively high sensitivity and specificity compared with CDFI and CEUS at low MI, CEUS at high MI offers an alternative complementary new method to detect TIPS abnormalities in clinic.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Gao X, Wang HH, Zhang YZ, et al. Contrast-enhanced ultrasound at high mechanical index: a new method for transjugular intrahepatic portosystemic shunt follow-up. Clin Radiol. 2019. PMID: 31767142. doi:10.1016/j.crad.2019.10.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。