以搏动指数校正的下肢动脉多普勒血流测量
研究纳入60名健康受试者,用双功能多普勒超声测量右下肢动脉直径、峰值收缩速度、搏动指数(PI)、时间平均平均速度和体积流量,建立体积流量与PI倒数的线性方程;并将该关系用于10例外周动脉疾病(PAD)患者经皮血管成形术前后血流变化的评估。结论认为将实时PI值纳入体积流量计算可解决流量测量差异,获得更准确稳定的测量。
要点
- 健康受试者各动脉体积流量:股总动脉434.4 mL/min、股浅动脉172.5 mL/min、腘动脉92.1 mL/min、足背动脉11.8 mL/min、足底总动脉12.0 mL/min。
- 体积流量与PI倒数呈线性关系,可表达为线性血流方程。
- PAD患者经皮血管成形术后下游动脉实测流量无统计学增加(p=0.1),但以PI校正后百分比增量计算出现统计学增加(p<0.001)。
核心结论
- 在评估下肢动脉时将实时PI值纳入体积流量计算,可解决流量测量差异,获得更准确、稳定且具有临床和诊断意义的测量。
研究设计与样本
- 研究纳入60名健康受试者,用双功能多普勒超声测量右下肢动脉的直径、峰值收缩速度、PI、时间平均平均速度和体积流量。
- 采用线性回归分析评估体积流量与PI倒数的关系,并将该定量关系用于10例PAD患者经皮血管成形术前、后或前后血流的评估。
诊断标准与关键数值
- 健康受试者股总动脉体积流量434.4 mL/min、股浅动脉172.5 mL/min、腘动脉92.1 mL/min、足背动脉11.8 mL/min、足底总动脉12.0 mL/min。
- 健康受试者中体积流量与PI倒数呈线性关系,并表达为线性血流方程。
- PAD患者经皮血管成形术后下游动脉实测流量无统计学增加(p=0.1),其中4条动脉流量下降。
- 以PI值校正流量测量后,百分比增量计算出现统计学增加(p<0.001)。
临床应用与阅片要点
- 原文结论认为,将实时PI值纳入下肢动脉体积流量计算可解决流量测量差异,获得更准确稳定的测量结果。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purposes of this study were to estimate the blood volume flow of the lower extremities by means of Doppler technique; to establish a quantitative relationship between volume flow and pulsatility index (PI) in both healthy subjects and patients with peripheral artery disease (PAD); and to derive arterial blood flow equations in the lower extremities for more accurate volume flow estimations. SUBJECTS AND METHODS. Sixty healthy subjects were recruited. Arterial diameter, peak systolic velocity, PI, time-averaged mean velocity, and volume flow of right lower extremity arteries were measured with duplex Doppler ultrasound. Linear regression analysis was used to evaluate the relationship between volume flow and the reciprocal of PI. This quantitative relationship was also used to assess flow changes in 10 patients with PAD before, after, or both before and after percutaneous angioplasty. RESULTS. Volume flow in the common femoral artery was 434.4 mL/min; superficial femoral artery, 172.5 mL/min; popliteal artery, 92.1 mL/min; dorsalis pedis artery, 11.8 mL/min; and common plantar artery, 12.0 mL/min. Linear relationships between the reciprocal of PI and volume flow were found and expressed as linear blood flow equations. For the patients with PAD, no statistical increase in measured flow in the downstream artery after percutaneous angioplasty was found (p = 0.1), although four arteries had decreased flow. After normalization of flow measurements with PI values, however, statistical increases were observed between percentage increment (p < 0.001) calculations. CONCLUSION. When real-time PI values are factored into blood volume flow calculations in the evaluation of lower extremity arteries, discrepancies in flow measurements can be resolved, resulting in more accurate and stable measurements of clinical and diagnostic significance.
引用
- Liang HL. Doppler Flow Measurement of Lower Extremity Arteries Adjusted by Pulsatility Index. AJR Am J Roentgenol. 2019. PMID: 31670583. doi:10.2214/AJR.19.21280
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。