同时多层涡轮自旋回波是否已可用于临床MRI?膝关节病变快速成像的可行性研究
前瞻性研究纳入10名健康志愿者和20例患者,在3 T下比较SMS(原型)与常规TSE序列的T1和PD加权脂肪抑制图像质量与诊断准确性。SMS诊断准确性与常规TSE相似,扫描时间显著缩短,图像质量总体相当,但线圈边缘附近有混叠伪影及T1加权图像软骨/骨CNR存在差异。
要点
- SMS TSE扫描时间显著短于常规TSE,诊断准确性与图像质量总体相似。
- SMS图像在线圈边缘附近可见混叠伪影,T1加权软骨/骨CNR与常规TSE不同。
- SMS可用于膝关节MRI检查,阅片时需关注线圈边缘伪影对病变显示的影响。
关键影像表现/征象
- SMS图像在线圈边缘附近出现混叠伪影,为SMS与常规TSE的定性差异之一。
- T1加权图像上SMS的软骨/骨CNR与常规TSE不同,为两序列定量差异之一。
诊断标准与关键数值
- 志愿者图像采用五点评分法评估伪影及骨、软骨、韧带和半月板显示。
- 患者SMS图像采用另一五点评分法评估图像锐利度、病变显示、与周围结构关系及病变整体伪影。
- 定量比较T1加权图像韧带/骨、半月板/骨、软骨/骨CNR及PD加权脂肪抑制图像韧带/积液、半月板/积液、软骨/积液、骨/积液CNR。
临床应用与阅片要点
- SMS TSE扫描时间显著缩短,诊断准确性与常规TSE相似,可用于膝关节MRI检查。
- 阅片时需注意SMS线圈边缘附近的混叠伪影,并留意T1加权图像软骨/骨CNR的差异。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the image quality and diagnostic accuracy of simultaneous multiple-section (SMS) turbo spin echo (TSE) magnetic resonance imaging (MRI) with gradient-based "controlled aliasing in parallel imaging results in higher acceleration" (CAIPIRINHA) for lesions of the knee.
MATERIALS AND METHODS: This prospective study included 10 healthy volunteers and 20 patients scanned at 3 T using SMS (a prototype) and conventional TSE sequences for T1 and proton-density (PD)-weighted imaging (with fat saturation). MRI images of volunteers were evaluated using a five-point score based on artefacts, and visualisation of the bone, cartilage, ligaments, and menisci. Contrast-to-noise ratios (CNRs) of ligament/bone, meniscus/bone, and cartilage/bone on T1-weighted images, as well as ligament/effusion, meniscus/effusion, cartilage/effusion, and bone/effusion on PD-weighted images (with fat saturation) were compared for better contrast. The SMS images for diagnosis of lesions of the knee were also evaluated using another five-point score: image sharpness, depiction of lesions, relationship to surrounding structures, and overall artefacts in the lesions.
RESULTS: Compared to conventional TSE sequences, SMS provides similar diagnostic accuracy with significantly reduced scan time. Furthermore, qualitative and quantitative analysis showed a comparable image quality between these two sequences except for the aliasing artefacts near the coil edges and CNR of cartilage/bone in T1-weighted images in SMS.
CONCLUSION: Compared to conventional TSE sequences, SMS requires shorter scan times and offers similar image quality and diagnostic accuracy. SMS is valuable for MRI examinations of the knee.
引用
- Li X, Peng Z, Sun Y, et al. Is simultaneous multisection turbo spin echo ready for clinical MRI? A feasibility study on fast imaging of knee lesions. Clin Radiol. 2019. PMID: 31767143. doi:10.1016/j.crad.2019.10.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。