超声微血流成像技术诊断肩关节粘连性关节囊炎
研究纳入39例粘连性关节囊炎患者和35例健康对照,用SMI和能量多普勒超声评估喙突下脂肪三角区血流,并分析其与临床特征的相关性。SMI面积在病例组为2.95 mm²、对照组为0 mm²(P < .01),SMI诊断AUC为0.90,优于其他超声指标,且SMI血流面积与外旋和前屈活动度负相关(P < .05)。
要点
- 喙突下脂肪三角区SMI血流面积病例组2.95 mm² vs 对照组0 mm²(P < .01)。
- SMI显示该区血流的能力优于能量多普勒超声(P < .01)。
- SMI血流面积与外旋和前屈活动度负相关(P < .05)。
关键影像表现/征象
- 常规超声评估肩袖间隙回声和喙肱韧带厚度。
- SMI和能量多普勒超声评估喙突下脂肪三角区血流(SMI面积和PDUS面积)。
诊断标准与关键数值
- SMI面积诊断粘连性关节囊炎的AUC为0.90,高于其他超声指标。
- SMI面积病例组2.95 mm² vs 对照组0 mm²(P < .01)。
- SMI显示喙突下脂肪三角区血流优于能量多普勒超声(P < .01)。
临床应用与阅片要点
- 作者结论认为SMI测量喙突下脂肪三角区血流有助于粘连性关节囊炎的诊断。
- SMI诊断性能优于能量多普勒超声。
- SMI血流面积与外旋和前屈活动度负相关(P < .05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic accuracy of Superb Microvascular Imaging (SMI; Canon Medical Systems, Otawara, Japan) at the subcoracoid triangle for adhesive capsulitis of the shoulder, to compare the diagnostic value of SMI with that of conventional ultrasound (US) and power Doppler ultrasound (PDUS) findings, and to investigate the correlation between vascular flow on SMI with clinical features.
METHODS: Our study included 39 patients with a diagnosis of adhesive capsulitis and 35 healthy patients as a control group. The echogenicity in the rotator interval and coracohumeral ligament thickness were assessed with conventional US. Vascular flow in the subcoracoid fat triangle was evaluated with SMI and PDUS (SMI and PDUS areas). A receiver operating characteristic curve analysis was performed to evaluate diagnostic accuracy. The correlation between US findings and the range of motion, pain intensity, and duration of symptoms was also evaluated.
RESULTS: The SMI area was higher in the adhesive capsulitis group than in the control group (2.95 versus 0 mm2 ; P < .01). The visualization of vascular flow at the subcoracoid fat triangle was superior with SMI compared with PDUS (P < .01). In the receiver operating characteristic analysis, the SMI area showed higher diagnostic performance, with an area under the curve of 0.90 compared with other US findings. The area of SMI vascular flow was also negatively correlated with external rotation and forward flexion (P < .05) in the adhesive capsulitis group.
CONCLUSIONS: Measurement of vascular flow at the subcoracoid fat triangle using SMI facilitated the diagnosis of adhesive capsulitis. Superb Microvascular Imaging was superior to PDUS in diagnostic performance. Vascular flow was negatively correlated with the range of motion of external rotation and forward flexion.
引用
- Kim DH, Choi YH, Oh S, et al. Ultrasound Microflow Imaging Technology for Diagnosis of Adhesive Capsulitis of the Shoulder. J Ultrasound Med. 2019. PMID: 31782541. doi:10.1002/jum.15181
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。