剪切波弹性成像测量的半月板硬度与半月板退变相关
该研究以组织学为参考标准,在13例因原发性骨关节炎伴内翻畸形行全膝关节置换术的患者中,对15个内侧和15个外侧半月板行剪切波弹性成像(SWE)检查,比较体内与离体测量。结果显示,随着组织学退变加重,体内和离体冠状面SWE所测硬度均显著增加,体内冠状面SWE的AUROC为0.79(95%CI:0.49-1.00)。作者结论认为SWE测得的半月板硬度值与半月板退变程度相关,并指出需进一步大规模前瞻性研究来确认其诊断效能。
要点
- 体内冠状面SWE评估半月板退变的AUROC为0.79(95%CI:0.49-1.00)。
- 离体冠状面SWE的AUROC为0.73(95%CI:0.53-0.95),离体矢状面SWE为0.56(95%CI:0.27-0.84)。
- 组织学退变加重时,体内和离体冠状面SWE所测硬度均显著增加。
核心结论
- SWE测得的半月板硬度值与半月板退变程度相关。
- 作者认为需进一步大规模前瞻性研究来确认SWE作为无创评估半月板退变工具的的诊断效能。
研究设计与样本
- 比较性体内与离体研究,纳入13例因原发性骨关节炎伴内翻畸形行全膝关节置换术的患者,共15个内侧和15个外侧半月板。
- 术前对半月板行体内冠状面SWE测量,全膝关节置换术后取组织行离体SWE测量,并以冠状面和矢状面分别测量。
- 以组织学为参考标准,按表面完整性、细胞密度、纤维排列、胶原排列和Safranin O染色强度进行0-18分退变分级。
- 采用Spearman相关分析SWE测量值与组织学分级的相关性,并用受试者工作特征曲线下面积(AUROC)计算诊断效能。
关键影像表现/征象
- 体内和离体冠状面SWE均显示,随着组织学退变加重,半月板硬度显著增加。
- 组织学分析显示内侧半月板退变更明显,离体冠状面SWE测得内侧半月板硬度大于外侧半月板。
诊断标准与关键数值
- 组织学退变分级采用0-18分制,依据表面完整性、细胞密度、纤维排列、胶原排列和Safranin O染色强度。
- 体内冠状面SWE诊断半月板退变的AUROC为0.79(95%CI:0.49-1.00)。
- 离体冠状面SWE的AUROC为0.73(95%CI:0.53-0.95),离体矢状面SWE的AUROC为0.56(95%CI:0.27-0.84)。
临床应用与阅片要点
- 冠状面SWE测量可能有助于评估半月板退变,体内冠状面SWE的AUROC为0.79(95%CI:0.49-1.00)。
- 离体矢状面SWE的AUROC为0.56(95%CI:0.27-0.84),提示该测量方向诊断效能有限。
局限性
- 原文结论指出需进一步大规模前瞻性研究来确认SWE的诊断效能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of this study was to evaluate the diagnostic performance of shear wave elastography (SWE) in human meniscus degeneration, with histology serving as the standard of reference. This comparative in vivo and ex vivo study was performed in 15 medial and 15 lateral menisci from 13 patients undergoing total knee arthroplasty (TKA) for primary osteoarthritis with varus deformity. Patients underwent in vivo coronal measurement with SWE for meniscus before surgery. Then, ex vivo assessment of meniscus stiffness with SWE was performed with the tissue obtained after TKA. SWE measurements were made in coronal and sagittal views with respect to the meniscus. Samples were analyzed histologically on a 0-18 scale according to the level of degeneration based on surface integrity, cellularity, fiber organization, collagen alignment and Safranin O staining intensity. The correlation between SWE measurement scale and histology was analyzed using Spearman's correlation. The area under the receiver operating characteristic curve (AUROC) was used to calculate the diagnostic performance of SWE in evaluating meniscus degeneration. Significant increases in stiffness were observed with increasing histologic degeneration in both in vivo and ex vivo coronal SWE. AUROCs were 0.79 (95% confidence interval [CI]: 0.49-1.00) for in vivo coronal SWE, 0.73 (95% CI: 0.53-0.95) for ex vivo coronal SWE and 0.56 (95% CI: 0.27-0.84) for ex vivo sagittal SWE. The medial meniscus, which exhibited more degeneration on histologic analysis, had greater stiffness than the lateral meniscus on ex vivo coronal SWE. The values of meniscus stiffness measured with SWE are correlated with the degree of meniscus degeneration. Further large-scale prospective studies may confirm the diagnostic performance of SWE as a non-invasive tool to assess meniscus degeneration.
引用
- Park JY, Kim JK, Cheon JE, et al. Meniscus Stiffness Measured with Shear Wave Elastography is Correlated with Meniscus Degeneration. Ultrasound Med Biol. 2019. PMID: 31753598. doi:10.1016/j.ultrasmedbio.2019.10.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。