全自动乳腺实质分析软件用于乳腺癌风险评估的临床评价:芬兰样本中的初步研究
这项回顾性病例对照研究纳入2016至2017年确诊的无症状乳腺癌女性的筛查乳腺X线摄影,将114例病例按出生年份、筛查年份和所用乳腺X线摄影系统与健康对照匹配。采用全自动公开软件OpenBreast进行实质分析,并与交互阈值法测量的乳腺百分比密度比较;调整年龄和百分比密度后,实质测量的标准化优势比每标准差变化为2.49(95%CI:1.79-3.47),区分病例与对照的AUC为0.779,高于百分比密度的0.609(p<0.001)。
要点
- OpenBreast实质测量区分乳腺癌病例与对照的AUC为0.779,优于百分比密度的0.609(p<0.001)。
- 调整年龄和百分比密度后,实质测量的每标准差优势比为2.49(95%CI:1.79-3.47)。
- 该软件为全自动、公开可用,但本研究为初步研究,结论需进一步验证。
核心结论
- OpenBreast获得的乳腺实质测量与乳腺癌风险呈正相关,且在风险预测中比百分比密度更准确。
研究设计与样本
- 回顾性病例对照研究,纳入2016至2017年确诊的无症状乳腺癌女性的筛查乳腺X线摄影。
- 114例病例按出生年份、筛查年份和所用乳腺X线摄影系统与健康对照匹配。
- 采用全自动、公开可用的OpenBreast软件进行实质分析,并以交互阈值法测量乳腺百分比密度作为比较。
诊断标准与关键数值
- 调整年龄和百分比密度后,实质测量的每标准差优势比(OPERA)为2.49(95%CI:1.79-3.47)。
- OpenBreast实质测量区分病例与对照的AUC为0.779,百分比密度的AUC为0.609,差异p<0.001(DeLong检验)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文标题标明为初步研究(pilot study)。
- 原文结论未明确列出其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the association between breast cancer risk and mammographic parenchymal measures obtained using a fully-automated, publicly available software, OpenBreast.
METHODS: This retrospective case-control study involved screening mammograms of asymptomatic women diagnosed with breast cancer between 2016 and 2017. The 114 cases were matched with corresponding healthy controls by birth and screening years and the mammographic system used. Parenchymal analysis was performed using OpenBreast, a software implementing a computerized parenchymal analysis algorithm. Breast percent density was measured with an interactive thresholding method. The parenchymal measures were Box-Cox transformed and adjusted for age and percent density. Changes in the odds ratio per standard deviation (OPERA) with 95% confidence intervals (CIs) and the area under the ROC curve (AUC) for parenchymal measures and percent densities were used to evaluate the discrimination between cases and controls. Differences in AUCs were assessed using DeLong's test.
RESULTS: The adjusted OPERA value of parenchymal measures was 2.49 (95% CI: 1.79-3.47). Parenchymal measures using OpenBreast were more accurate (AUC = 0.779) than percent density (AUC = 0.609) in discriminating between cases and controls (p < 0.001).
CONCLUSIONS: Parenchymal measures obtained with the evaluated software were positively associated with breast cancer risk and were more accurate than percent density in the prediction of risk.
引用
- Pertuz S, Sassi A, Holli-Helenius K, et al. Clinical evaluation of a fully-automated parenchymal analysis software for breast cancer risk assessment: A pilot study in a Finnish sample. Eur J Radiol. 2019. PMID: 31689665. doi:10.1016/j.ejrad.2019.108710
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。