文献速递乳腺技术与安全US

基于原发性乳腺癌超声图像的深度学习预测淋巴结转移

Lymph Node Metastasis Prediction from Primary Breast Cancer US Images Using Deep Learning.
PubMed 文献 · Radiology · 2019-11-19

本研究利用同济医院974例原发性乳腺癌且临床腋窝淋巴结阴性患者的超声图像训练三种卷积神经网络,并在湖北肿瘤医院81例独立测试集上验证。表现最佳的Inception V3模型预测腋窝淋巴结转移的AUC为0.89,敏感度85%、特异度73%,高于5名放射科医师的73%和63%,但差异未达统计学显著。

要点

  • Inception V3模型在独立测试集预测腋窝淋巴结转移的AUC为0.89。
  • 模型敏感度85%(35/41)、特异度73%(29/40),放射科医师分别为73%(30/41)和63%(25/40)。
  • 模型与医师敏感度比较P=.17、特异度比较P=.34,差异未达统计学显著。

核心结论

  • 使用原发性乳腺癌患者的超声图像,深度学习模型可有效预测临床阴性腋窝淋巴结转移。
  • 人工智能可能为临床淋巴结阴性的乳腺癌患者提供淋巴结转移的早期诊断策略。

研究设计与样本

  • 研究为深度学习模型开发与验证研究,训练集来自同济医院2016至2018年的974次影像检查(756例患者)。
  • 独立测试集来自湖北肿瘤医院2018至2019年的81次影像检查(78例患者)。
  • 腋窝淋巴结状态以病理检查为参考标准确认。
  • 训练Inception V3、Inception-ResNet V2和ResNet-101三种卷积神经网络,在90%同济医院数据上训练、10%及独立测试集上测试。
  • 模型性能与5名放射科医师进行比较。

关键影像表现/征象

  • 原文未报告具体影像征象,模型以热图形式分析。

诊断标准与关键数值

  • 最佳模型Inception V3在独立测试集预测最终临床诊断腋窝淋巴结转移的AUC为0.89(95%CI:0.83,0.95)。
  • Inception V3敏感度85%(35/41;95%CI:70%,94%),特异度73%(29/40;95%CI:56%,85%)。
  • 放射科医师敏感度73%(30/41;95%CI:57%,85%;P=.17),特异度63%(25/40;95%CI:46%,77%;P=.34)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Deep learning (DL) algorithms are gaining extensive attention for their excellent performance in image recognition tasks. DL models can automatically make a quantitative assessment of complex medical image characteristics and achieve increased accuracy in diagnosis with higher efficiency. Purpose To determine the feasibility of using a DL approach to predict clinically negative axillary lymph node metastasis from US images in patients with primary breast cancer. Materials and Methods A data set of US images in patients with primary breast cancer with clinically negative axillary lymph nodes from Tongji Hospital (974 imaging studies from 2016 to 2018, 756 patients) and an independent test set from Hubei Cancer Hospital (81 imaging studies from 2018 to 2019, 78 patients) were collected. Axillary lymph node status was confirmed with pathologic examination. Three different convolutional neural networks (CNNs) of Inception V3, Inception-ResNet V2, and ResNet-101 architectures were trained on 90% of the Tongji Hospital data set and tested on the remaining 10%, as well as on the independent test set. The performance of the models was compared with that of five radiologists. The models' performance was analyzed in terms of accuracy, sensitivity, specificity, receiver operating characteristic curves, areas under the receiver operating characteristic curve (AUCs), and heat maps. Results The best-performing CNN model, Inception V3, achieved an AUC of 0.89 (95% confidence interval [CI]: 0.83, 0.95) in the prediction of the final clinical diagnosis of axillary lymph node metastasis in the independent test set. The model achieved 85% sensitivity (35 of 41 images; 95% CI: 70%, 94%) and 73% specificity (29 of 40 images; 95% CI: 56%, 85%), and the radiologists achieved 73% sensitivity (30 of 41 images; 95% CI: 57%, 85%; P = .17) and 63% specificity (25 of 40 images; 95% CI: 46%, 77%; P = .34). Conclusion Using US images from patients with primary breast cancer, deep learning models can effectively predict clinically negative axillary lymph node metastasis. Artificial intelligence may provide an early diagnostic strategy for lymph node metastasis in patients with breast cancer with clinically negative lymph nodes. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Bae in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Zhou LQ, Wu XL, Huang SY, et al. Lymph Node Metastasis Prediction from Primary Breast Cancer US Images Using Deep Learning. Radiology. 2019. PMID: 31746687. doi:10.1148/radiol.2019190372

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。